股骨翻修髋关节置换术的长期随访结果采用阻骨移植和标准骨水泥抛光柄。

IF 1.9 2区 医学 Q2 ORTHOPEDICS
Clinics in Orthopedic Surgery Pub Date : 2023-10-01 Epub Date: 2023-09-15 DOI:10.4055/cios23052
Jin Sung Park, Seok Hyun Kweon, Sung Ju Kang, Yang Hun Jo
{"title":"股骨翻修髋关节置换术的长期随访结果采用阻骨移植和标准骨水泥抛光柄。","authors":"Jin Sung Park,&nbsp;Seok Hyun Kweon,&nbsp;Sung Ju Kang,&nbsp;Yang Hun Jo","doi":"10.4055/cios23052","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>To report the long-term clinical and radiologic results of impaction bone grafting and standard cemented polished stem for femoral revision arthroplasty in patients with extensive bone deficiency.</p><p><strong>Methods: </strong>We retrospectively reviewed 47 hips that underwent femoral revision hip arthroplasty using an impaction-morselized allograft with a standard cemented polished stem. The average age at the time of revision hip arthroplasty was 55 years (range, 39-75 years). The modified Harris hip score (HHS) was used for clinical evaluation. The radiologic evaluation focused on stem subsidence, stem position, progressive radiolucent lines, bone remodeling, and the incorporation of allografts.</p><p><strong>Results: </strong>The modified HHS improved from an average of 55.04 (range, 25-79.5) preoperatively to 90.1 (range, 81-93.2) at the last follow-up. The mean follow-up duration was 13.5 years (10.9-17.8 years). The radiographic analysis revealed stable stems. Femoral stems showed an average subsidence of 3.2 mm (range, 2-8 mm) in the cement mantle. However, there was no mechanical failure or subsidence of the cement mantle in the femurs. The stem position was neutral or varus less than 5°. No progressive radiolucent line or osteolysis was observed. Evidence of cortical and trabecular remodeling was observed in all cases. There were four cases of intraoperative cracks and four cases of distal femur splitting.</p><p><strong>Conclusions: </strong>Initial stem stability using impaction bone grafting and a standard cemented polished stem in femoral revision arthroplasty resulted in good outcome. Delicate impaction grafting techniques and intraoperative crack and splitting fixation are the points that need attention for successful long-term results.</p>","PeriodicalId":47648,"journal":{"name":"Clinics in Orthopedic Surgery","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/54/8c/cios-15-734.PMC10551692.pdf","citationCount":"0","resultStr":"{\"title\":\"Long-term Follow-up Results of Femoral Revision Hip Arthroplasty Using Impaction Bone Grafting and Standard Cemented Polished Stem.\",\"authors\":\"Jin Sung Park,&nbsp;Seok Hyun Kweon,&nbsp;Sung Ju Kang,&nbsp;Yang Hun Jo\",\"doi\":\"10.4055/cios23052\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>To report the long-term clinical and radiologic results of impaction bone grafting and standard cemented polished stem for femoral revision arthroplasty in patients with extensive bone deficiency.</p><p><strong>Methods: </strong>We retrospectively reviewed 47 hips that underwent femoral revision hip arthroplasty using an impaction-morselized allograft with a standard cemented polished stem. The average age at the time of revision hip arthroplasty was 55 years (range, 39-75 years). The modified Harris hip score (HHS) was used for clinical evaluation. The radiologic evaluation focused on stem subsidence, stem position, progressive radiolucent lines, bone remodeling, and the incorporation of allografts.</p><p><strong>Results: </strong>The modified HHS improved from an average of 55.04 (range, 25-79.5) preoperatively to 90.1 (range, 81-93.2) at the last follow-up. The mean follow-up duration was 13.5 years (10.9-17.8 years). The radiographic analysis revealed stable stems. Femoral stems showed an average subsidence of 3.2 mm (range, 2-8 mm) in the cement mantle. However, there was no mechanical failure or subsidence of the cement mantle in the femurs. The stem position was neutral or varus less than 5°. No progressive radiolucent line or osteolysis was observed. Evidence of cortical and trabecular remodeling was observed in all cases. There were four cases of intraoperative cracks and four cases of distal femur splitting.</p><p><strong>Conclusions: </strong>Initial stem stability using impaction bone grafting and a standard cemented polished stem in femoral revision arthroplasty resulted in good outcome. Delicate impaction grafting techniques and intraoperative crack and splitting fixation are the points that need attention for successful long-term results.</p>\",\"PeriodicalId\":47648,\"journal\":{\"name\":\"Clinics in Orthopedic Surgery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2023-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/54/8c/cios-15-734.PMC10551692.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinics in Orthopedic Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4055/cios23052\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/9/15 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinics in Orthopedic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4055/cios23052","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/9/15 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

背景:报道广泛性骨缺乏患者应用嵌塞骨移植和标准骨水泥抛光柄进行股骨翻修的长期临床和放射学结果。方法:我们回顾性地回顾了47例髋关节,这些髋关节使用标准骨水泥抛光柄的冲击颗粒同种异体移植物进行了股骨翻修髋关节置换术。髋关节置换术翻修时的平均年龄为55岁(范围39-75岁)。采用改良哈里斯髋关节评分(HHS)进行临床评价。放射学评估的重点是干细胞沉降、干细胞位置、进行性透射线、骨重建和同种异体移植物的结合。结果:改良HHS从术前的平均55.04(范围25-79.5)改善到最后一次随访时的90.1(范围81-93.2)。平均随访时间为13.5年(10.9-17.8年)。射线照相分析显示茎干稳定。股骨柄在水泥套中的平均沉降量为3.2毫米(范围为2-8毫米)。然而,股骨中没有出现机械故障或水泥地幔沉降。脑干位置为中性或内翻小于5°。未观察到进行性透射线或骨溶解。在所有病例中均观察到皮质和小梁重塑的证据。术中有4例骨折,4例股骨远端骨折。结论:在股骨翻修关节成形术中,使用嵌塞骨移植和标准的水泥抛光股骨柄可获得良好的初始股骨柄稳定性。精细的嵌塞移植技术和术中裂裂固定是取得长期成功需要注意的要点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Long-term Follow-up Results of Femoral Revision Hip Arthroplasty Using Impaction Bone Grafting and Standard Cemented Polished Stem.

Long-term Follow-up Results of Femoral Revision Hip Arthroplasty Using Impaction Bone Grafting and Standard Cemented Polished Stem.

Long-term Follow-up Results of Femoral Revision Hip Arthroplasty Using Impaction Bone Grafting and Standard Cemented Polished Stem.

Long-term Follow-up Results of Femoral Revision Hip Arthroplasty Using Impaction Bone Grafting and Standard Cemented Polished Stem.

Background: To report the long-term clinical and radiologic results of impaction bone grafting and standard cemented polished stem for femoral revision arthroplasty in patients with extensive bone deficiency.

Methods: We retrospectively reviewed 47 hips that underwent femoral revision hip arthroplasty using an impaction-morselized allograft with a standard cemented polished stem. The average age at the time of revision hip arthroplasty was 55 years (range, 39-75 years). The modified Harris hip score (HHS) was used for clinical evaluation. The radiologic evaluation focused on stem subsidence, stem position, progressive radiolucent lines, bone remodeling, and the incorporation of allografts.

Results: The modified HHS improved from an average of 55.04 (range, 25-79.5) preoperatively to 90.1 (range, 81-93.2) at the last follow-up. The mean follow-up duration was 13.5 years (10.9-17.8 years). The radiographic analysis revealed stable stems. Femoral stems showed an average subsidence of 3.2 mm (range, 2-8 mm) in the cement mantle. However, there was no mechanical failure or subsidence of the cement mantle in the femurs. The stem position was neutral or varus less than 5°. No progressive radiolucent line or osteolysis was observed. Evidence of cortical and trabecular remodeling was observed in all cases. There were four cases of intraoperative cracks and four cases of distal femur splitting.

Conclusions: Initial stem stability using impaction bone grafting and a standard cemented polished stem in femoral revision arthroplasty resulted in good outcome. Delicate impaction grafting techniques and intraoperative crack and splitting fixation are the points that need attention for successful long-term results.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.50
自引率
4.00%
发文量
85
审稿时长
36 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信