用数字听诊器测量鸟类心率:不同心音图计数方法的比较。

IF 0.6 4区 农林科学 Q3 VETERINARY SCIENCES
Ciro Cococcetta, Thomas Coutant, Sophie Bagur, Morena Bernadette Wernick, Minh Huynh
{"title":"用数字听诊器测量鸟类心率:不同心音图计数方法的比较。","authors":"Ciro Cococcetta,&nbsp;Thomas Coutant,&nbsp;Sophie Bagur,&nbsp;Morena Bernadette Wernick,&nbsp;Minh Huynh","doi":"10.1647/22-00047","DOIUrl":null,"url":null,"abstract":"<p><p>The high cardiac contractility of birds poses a challenge to traditional cardiac auscultation, particularly for the accurate determination of heart rate (HR). The objectives of this study were to 1) evaluate the feasibility of using phonocardiograms of adequate length and quality to assess HR in different avian species with a commercially available digital stethoscope, 2) compare 5 counting methods, including 2 direct reading methods (manual counting and using a semiautomatic computerized algorithm as a reference method) and 3 listening methods (progressive mental counting, counting by 10s, and counting with a smartphone application tap counter), and 3) obtain the HR in selected birds and identify a correlation between body weight and HR in different avian species. An inverse correlation on a logarithmic scale was identified between the mean body weight and HR in 60 different bird species (n = 211; R = -0.72, <i>P</i> < 0.0001). Manual reading of phonocardiograms was the most reliable method and had the highest agreement with the reference method; this was followed by the counting by 10s method, the tapping method, and the progressive mental counting method, which was the least reliable. The agreement levels for the different methods were comparable for HRs <200 beats per minute (bpm) in birds weighing >1 kg. For HRs >500 bpm in birds weighing <150 g, only the reading method maintained a good agreement level. A digital stethoscope can be a useful tool for accurately determining the HR in birds, including very small species with high HRs.</p>","PeriodicalId":15102,"journal":{"name":"Journal of Avian Medicine and Surgery","volume":"37 2","pages":"108-117"},"PeriodicalIF":0.6000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Use of Digital Stethoscope to Measure Heart Rate in Birds: Comparison of Different Counting Methods Using Phonocardiograms.\",\"authors\":\"Ciro Cococcetta,&nbsp;Thomas Coutant,&nbsp;Sophie Bagur,&nbsp;Morena Bernadette Wernick,&nbsp;Minh Huynh\",\"doi\":\"10.1647/22-00047\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The high cardiac contractility of birds poses a challenge to traditional cardiac auscultation, particularly for the accurate determination of heart rate (HR). The objectives of this study were to 1) evaluate the feasibility of using phonocardiograms of adequate length and quality to assess HR in different avian species with a commercially available digital stethoscope, 2) compare 5 counting methods, including 2 direct reading methods (manual counting and using a semiautomatic computerized algorithm as a reference method) and 3 listening methods (progressive mental counting, counting by 10s, and counting with a smartphone application tap counter), and 3) obtain the HR in selected birds and identify a correlation between body weight and HR in different avian species. An inverse correlation on a logarithmic scale was identified between the mean body weight and HR in 60 different bird species (n = 211; R = -0.72, <i>P</i> < 0.0001). Manual reading of phonocardiograms was the most reliable method and had the highest agreement with the reference method; this was followed by the counting by 10s method, the tapping method, and the progressive mental counting method, which was the least reliable. The agreement levels for the different methods were comparable for HRs <200 beats per minute (bpm) in birds weighing >1 kg. For HRs >500 bpm in birds weighing <150 g, only the reading method maintained a good agreement level. A digital stethoscope can be a useful tool for accurately determining the HR in birds, including very small species with high HRs.</p>\",\"PeriodicalId\":15102,\"journal\":{\"name\":\"Journal of Avian Medicine and Surgery\",\"volume\":\"37 2\",\"pages\":\"108-117\"},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2023-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Avian Medicine and Surgery\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.1647/22-00047\",\"RegionNum\":4,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Avian Medicine and Surgery","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1647/22-00047","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

鸟类的高心脏收缩力对传统的心脏听诊提出了挑战,尤其是对准确测定心率(HR)提出了挑战。本研究的目的是:1)评估使用足够长度和质量的心音图用商用数字听诊器评估不同鸟类HR的可行性;2)比较5种计数方法,包括2种直读方法(手动计数,使用半自动计算机算法作为参考方法)和3种听法(渐进式心理计数、10秒计数和使用智能手机应用程序敲击计数器计数),以及3)获得所选鸟类的HR,并确定不同鸟类的体重与HR之间的相关性。60种不同鸟类的平均体重和心率在对数尺度上呈负相关(n=211;R=-0.72,P<0.0001)。人工读取心音图是最可靠的方法,与参考方法的一致性最高;其次是10s计数法、敲击法和渐进式心理计数法,这是最不可靠的。不同方法的一致性水平在HRs 1 kg的情况下是可比较的。对于体重超过500 bpm的鸟类
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Use of Digital Stethoscope to Measure Heart Rate in Birds: Comparison of Different Counting Methods Using Phonocardiograms.

The high cardiac contractility of birds poses a challenge to traditional cardiac auscultation, particularly for the accurate determination of heart rate (HR). The objectives of this study were to 1) evaluate the feasibility of using phonocardiograms of adequate length and quality to assess HR in different avian species with a commercially available digital stethoscope, 2) compare 5 counting methods, including 2 direct reading methods (manual counting and using a semiautomatic computerized algorithm as a reference method) and 3 listening methods (progressive mental counting, counting by 10s, and counting with a smartphone application tap counter), and 3) obtain the HR in selected birds and identify a correlation between body weight and HR in different avian species. An inverse correlation on a logarithmic scale was identified between the mean body weight and HR in 60 different bird species (n = 211; R = -0.72, P < 0.0001). Manual reading of phonocardiograms was the most reliable method and had the highest agreement with the reference method; this was followed by the counting by 10s method, the tapping method, and the progressive mental counting method, which was the least reliable. The agreement levels for the different methods were comparable for HRs <200 beats per minute (bpm) in birds weighing >1 kg. For HRs >500 bpm in birds weighing <150 g, only the reading method maintained a good agreement level. A digital stethoscope can be a useful tool for accurately determining the HR in birds, including very small species with high HRs.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Avian Medicine and Surgery
Journal of Avian Medicine and Surgery 农林科学-兽医学
CiteScore
0.90
自引率
0.00%
发文量
52
审稿时长
>36 weeks
期刊介绍: The Journal of Avian Medicine and Surgery is an international journal of the medicine and surgery of both captive and wild birds. Published materials include scientific articles, case reports, editorials, abstracts, new research, and book reviews.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信