Yong Zhang, Yingluo Gu, Jupu Zhou, Jiaju Zhao, Bo Jiang
{"title":"改良双克氏针直接固定骨折片治疗陈旧性骨槌指。","authors":"Yong Zhang, Yingluo Gu, Jupu Zhou, Jiaju Zhao, Bo Jiang","doi":"10.2340/jphs.v58.18306","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The management of old bony mallet fingers is complicated. The purpose of this study was to describe direct fixation of fracture fragment with modified double Kirschner wires (K-wires) for treatment of old bony mallet finger, and to evaluate the functional outcomes during long-term follow-up.</p><p><strong>Methods: </strong>Forty-nine patients with old bony mallet finger were enrolled and underwent surgical treatment from August 2014 to January 2021 in our hospital. Patients were divided into two groups according to whether they had undergone triple K-wires fixation or modified double K-wires with a dorsal brace fixation. The operation time, mean number of intraoperative fluoroscopy, bone union time, functional recovery and incidence of complications were monitored.</p><p><strong>Results: </strong>Neither QuickDASH nor visual analogue scale measurement found statistically significant difference between the two groups (P > 0.05). However, the patients that underwent fixation with double K-wires and a dorsal brace required a shorter operation time and fewer intraoperative fluoroscopy, and exhibited a significantly greater mean final active range of the distal interphalangeal joint flexion, compared to those treated with triple K-wires (P < 0.01).</p><p><strong>Conclusion: </strong>Direct fixation of fracture fragment with modified double K-wires was an easy and feasible procedure which could achieve anatomical reduction and stable fixation of the dorsal fracture block of old bony mallet finger with relatively few complications.</p>","PeriodicalId":16847,"journal":{"name":"Journal of Plastic Surgery and Hand Surgery","volume":"58 ","pages":"119-123"},"PeriodicalIF":1.0000,"publicationDate":"2023-09-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Direct fixation of fracture fragment with modified double Kirschner wires for the treatment of old bony mallet finger.\",\"authors\":\"Yong Zhang, Yingluo Gu, Jupu Zhou, Jiaju Zhao, Bo Jiang\",\"doi\":\"10.2340/jphs.v58.18306\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The management of old bony mallet fingers is complicated. The purpose of this study was to describe direct fixation of fracture fragment with modified double Kirschner wires (K-wires) for treatment of old bony mallet finger, and to evaluate the functional outcomes during long-term follow-up.</p><p><strong>Methods: </strong>Forty-nine patients with old bony mallet finger were enrolled and underwent surgical treatment from August 2014 to January 2021 in our hospital. Patients were divided into two groups according to whether they had undergone triple K-wires fixation or modified double K-wires with a dorsal brace fixation. The operation time, mean number of intraoperative fluoroscopy, bone union time, functional recovery and incidence of complications were monitored.</p><p><strong>Results: </strong>Neither QuickDASH nor visual analogue scale measurement found statistically significant difference between the two groups (P > 0.05). However, the patients that underwent fixation with double K-wires and a dorsal brace required a shorter operation time and fewer intraoperative fluoroscopy, and exhibited a significantly greater mean final active range of the distal interphalangeal joint flexion, compared to those treated with triple K-wires (P < 0.01).</p><p><strong>Conclusion: </strong>Direct fixation of fracture fragment with modified double K-wires was an easy and feasible procedure which could achieve anatomical reduction and stable fixation of the dorsal fracture block of old bony mallet finger with relatively few complications.</p>\",\"PeriodicalId\":16847,\"journal\":{\"name\":\"Journal of Plastic Surgery and Hand Surgery\",\"volume\":\"58 \",\"pages\":\"119-123\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2023-09-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Plastic Surgery and Hand Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2340/jphs.v58.18306\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Plastic Surgery and Hand Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2340/jphs.v58.18306","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Direct fixation of fracture fragment with modified double Kirschner wires for the treatment of old bony mallet finger.
Background: The management of old bony mallet fingers is complicated. The purpose of this study was to describe direct fixation of fracture fragment with modified double Kirschner wires (K-wires) for treatment of old bony mallet finger, and to evaluate the functional outcomes during long-term follow-up.
Methods: Forty-nine patients with old bony mallet finger were enrolled and underwent surgical treatment from August 2014 to January 2021 in our hospital. Patients were divided into two groups according to whether they had undergone triple K-wires fixation or modified double K-wires with a dorsal brace fixation. The operation time, mean number of intraoperative fluoroscopy, bone union time, functional recovery and incidence of complications were monitored.
Results: Neither QuickDASH nor visual analogue scale measurement found statistically significant difference between the two groups (P > 0.05). However, the patients that underwent fixation with double K-wires and a dorsal brace required a shorter operation time and fewer intraoperative fluoroscopy, and exhibited a significantly greater mean final active range of the distal interphalangeal joint flexion, compared to those treated with triple K-wires (P < 0.01).
Conclusion: Direct fixation of fracture fragment with modified double K-wires was an easy and feasible procedure which could achieve anatomical reduction and stable fixation of the dorsal fracture block of old bony mallet finger with relatively few complications.
期刊介绍:
The purpose of the Journal of Plastic Surgery and Hand Surgery is to serve as an international forum for plastic surgery, hand surgery and related research. Interest is focused on original articles on basic research and clinical evaluation.
The scope of the journal comprises:
• Articles concerning operative methods and follow-up studies
• Research articles on subjects related to plastic and hand surgery
• Articles on cranio-maxillofacial surgery, including cleft lip and palate surgery.
Extended issues are published occasionally, dealing with special topics such as microvascular surgery, craniofacial surgery, or burns. Supplements, usually doctoral theses, may also be published.
The journal is published for the Acta Chirurgica Scandinavica society and sponsored by the Key Foundation, Sweden.
The journal was previously published as Scandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery.