二次pH测量法在标准物质均匀性和稳定性评价中的应用

IF 0.8 4区 工程技术 Q4 CHEMISTRY, ANALYTICAL
Boryana Koleva, Lyudmila Dimitrova, Daniela Stoica, Paola Fisicaro
{"title":"二次pH测量法在标准物质均匀性和稳定性评价中的应用","authors":"Boryana Koleva,&nbsp;Lyudmila Dimitrova,&nbsp;Daniela Stoica,&nbsp;Paola Fisicaro","doi":"10.1007/s00769-021-01464-w","DOIUrl":null,"url":null,"abstract":"<p>In this work, the development and optimization of a secondary method for pH measurement using a differential potentiometric cell are described. The method was optimized and validated by measurement of three certified primary buffer solutions (CRMs) with nominal pH values of 4.005, 6.865 and 9.180 at 25?°C. The method was applied to assess homogeneity and stability of phosphate buffer solution with nominal pH of 7.000 at 25?°C which will be used as test item in proficiency testing schemes for pH measurement of testing laboratories. The experiments carried out and described in this article proved that this particular design of secondary differential potentiometric cell requires small volume of solutions, is fast, accurate and precise and is suitable for the characterization of secondary buffer solutions and assessment of homogeneity and stability of buffer solutions.</p>","PeriodicalId":454,"journal":{"name":"Accreditation and Quality Assurance","volume":"26 2","pages":"113 - 120"},"PeriodicalIF":0.8000,"publicationDate":"2021-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/s00769-021-01464-w","citationCount":"3","resultStr":"{\"title\":\"Application of secondary pH measurement method for homogeneity and stability assessment of reference materials\",\"authors\":\"Boryana Koleva,&nbsp;Lyudmila Dimitrova,&nbsp;Daniela Stoica,&nbsp;Paola Fisicaro\",\"doi\":\"10.1007/s00769-021-01464-w\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>In this work, the development and optimization of a secondary method for pH measurement using a differential potentiometric cell are described. The method was optimized and validated by measurement of three certified primary buffer solutions (CRMs) with nominal pH values of 4.005, 6.865 and 9.180 at 25?°C. The method was applied to assess homogeneity and stability of phosphate buffer solution with nominal pH of 7.000 at 25?°C which will be used as test item in proficiency testing schemes for pH measurement of testing laboratories. The experiments carried out and described in this article proved that this particular design of secondary differential potentiometric cell requires small volume of solutions, is fast, accurate and precise and is suitable for the characterization of secondary buffer solutions and assessment of homogeneity and stability of buffer solutions.</p>\",\"PeriodicalId\":454,\"journal\":{\"name\":\"Accreditation and Quality Assurance\",\"volume\":\"26 2\",\"pages\":\"113 - 120\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2021-04-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1007/s00769-021-01464-w\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accreditation and Quality Assurance\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s00769-021-01464-w\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accreditation and Quality Assurance","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s00769-021-01464-w","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 3

摘要

在这项工作中,开发和优化了一种二次方法,用于pH测量使用差动电位电池描述。通过在25°C下测量3种标称pH值分别为4.005、6.865和9.180的认证初级缓冲溶液(CRMs),对该方法进行了优化和验证。该方法用于评价标称pH为7.000的磷酸盐缓冲液在25?°C,将作为测试实验室pH测量能力测试方案的测试项目。本文所进行的实验证明,这种特殊设计的二次差动电位池需要的溶液体积小,快速、准确、精密,适用于二次缓冲溶液的表征和缓冲溶液的均匀性和稳定性评价。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Application of secondary pH measurement method for homogeneity and stability assessment of reference materials

Application of secondary pH measurement method for homogeneity and stability assessment of reference materials

In this work, the development and optimization of a secondary method for pH measurement using a differential potentiometric cell are described. The method was optimized and validated by measurement of three certified primary buffer solutions (CRMs) with nominal pH values of 4.005, 6.865 and 9.180 at 25?°C. The method was applied to assess homogeneity and stability of phosphate buffer solution with nominal pH of 7.000 at 25?°C which will be used as test item in proficiency testing schemes for pH measurement of testing laboratories. The experiments carried out and described in this article proved that this particular design of secondary differential potentiometric cell requires small volume of solutions, is fast, accurate and precise and is suitable for the characterization of secondary buffer solutions and assessment of homogeneity and stability of buffer solutions.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Accreditation and Quality Assurance
Accreditation and Quality Assurance 工程技术-分析化学
CiteScore
1.80
自引率
22.20%
发文量
39
审稿时长
6-12 weeks
期刊介绍: Accreditation and Quality Assurance has established itself as the leading information and discussion forum for all aspects relevant to quality, transparency and reliability of measurement results in chemical and biological sciences. The journal serves the information needs of researchers, practitioners and decision makers dealing with quality assurance and quality management, including the development and application of metrological principles and concepts such as traceability or measurement uncertainty in the following fields: environment, nutrition, consumer protection, geology, metallurgy, pharmacy, forensics, clinical chemistry and laboratory medicine, and microbiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信