[综合医院CT分管人员低剂量CT检测肺结节的能力分析]。

Akitoshi Saito, Atsushi Nambu, Tsutomu Araki
{"title":"[综合医院CT分管人员低剂量CT检测肺结节的能力分析]。","authors":"Akitoshi Saito,&nbsp;Atsushi Nambu,&nbsp;Tsutomu Araki","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To examine the ability of radiological technologists (RT) to detect pulmonary nodules with low-dose CT (LCT).</p><p><strong>Materials and methods: </strong>LCT (20 mAs) and normal-dose CT (NCT; 160 mAs) were performed in 60 patients. We used an RT to detect pulmonary nodules with LCT. The results were compared with those of a radiologist who detected nodules with NCT. The diameter and density of the nodules in NCT were compared between the group of nodules detected (DN) by the RT and the group of nodules not detected (NN).</p><p><strong>Results: </strong>60 nodules were detected with LCT out of 74 nodules detected with NCT (81.1%). Eleven patients had NN as well as DN. The mean diameter of NN was smaller than that of DN, and the density of NN was lower than that of DN.</p><p><strong>Conclusion: </strong>The detection of pulmonary nodules with LCT by radiological technologists was acceptable.</p>","PeriodicalId":19251,"journal":{"name":"Nihon Igaku Hoshasen Gakkai zasshi. Nippon acta radiologica","volume":"65 2","pages":"109-13"},"PeriodicalIF":0.0000,"publicationDate":"2005-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Ability of radiological technologists in charge of CT in a general hospital to detect pulmonary nodules with low-dose CT].\",\"authors\":\"Akitoshi Saito,&nbsp;Atsushi Nambu,&nbsp;Tsutomu Araki\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To examine the ability of radiological technologists (RT) to detect pulmonary nodules with low-dose CT (LCT).</p><p><strong>Materials and methods: </strong>LCT (20 mAs) and normal-dose CT (NCT; 160 mAs) were performed in 60 patients. We used an RT to detect pulmonary nodules with LCT. The results were compared with those of a radiologist who detected nodules with NCT. The diameter and density of the nodules in NCT were compared between the group of nodules detected (DN) by the RT and the group of nodules not detected (NN).</p><p><strong>Results: </strong>60 nodules were detected with LCT out of 74 nodules detected with NCT (81.1%). Eleven patients had NN as well as DN. The mean diameter of NN was smaller than that of DN, and the density of NN was lower than that of DN.</p><p><strong>Conclusion: </strong>The detection of pulmonary nodules with LCT by radiological technologists was acceptable.</p>\",\"PeriodicalId\":19251,\"journal\":{\"name\":\"Nihon Igaku Hoshasen Gakkai zasshi. Nippon acta radiologica\",\"volume\":\"65 2\",\"pages\":\"109-13\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nihon Igaku Hoshasen Gakkai zasshi. Nippon acta radiologica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nihon Igaku Hoshasen Gakkai zasshi. Nippon acta radiologica","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:探讨低剂量CT (LCT)检测肺结节的能力。材料和方法:LCT (20 ma)和正常剂量CT (NCT;60例患者行160例mAs检查。我们使用RT与LCT检测肺结节。将结果与用NCT检测结节的放射科医生的结果进行比较。比较RT检测到结节组(DN)和未检测到结节组(NN) NCT内结节的直径和密度。结果:NCT检出74个结节,LCT检出60个,占81.1%。11例患者合并NN和DN。NN的平均直径小于DN, NN的密度小于DN。结论:ct对肺结节的检测是可以接受的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Ability of radiological technologists in charge of CT in a general hospital to detect pulmonary nodules with low-dose CT].

Purpose: To examine the ability of radiological technologists (RT) to detect pulmonary nodules with low-dose CT (LCT).

Materials and methods: LCT (20 mAs) and normal-dose CT (NCT; 160 mAs) were performed in 60 patients. We used an RT to detect pulmonary nodules with LCT. The results were compared with those of a radiologist who detected nodules with NCT. The diameter and density of the nodules in NCT were compared between the group of nodules detected (DN) by the RT and the group of nodules not detected (NN).

Results: 60 nodules were detected with LCT out of 74 nodules detected with NCT (81.1%). Eleven patients had NN as well as DN. The mean diameter of NN was smaller than that of DN, and the density of NN was lower than that of DN.

Conclusion: The detection of pulmonary nodules with LCT by radiological technologists was acceptable.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信