采用即刻加载方案的双种植体下颌覆盖义齿的种植体位置与骨嵴骨质流失的相关性:前瞻性临床研究。

IF 4.3 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
{"title":"采用即刻加载方案的双种植体下颌覆盖义齿的种植体位置与骨嵴骨质流失的相关性:前瞻性临床研究。","authors":"","doi":"10.1016/j.prosdent.2022.09.007","DOIUrl":null,"url":null,"abstract":"<div><h3>Statement of problem</h3><div><span>The 2-implant mandibular overdenture (2IMO) is a popular treatment for patients with an </span>edentulous mandible, but information on the effect of the optimum implant position on the peri-implant crestal bone level with immediate loading protocols is lacking.</div></div><div><h3>Purpose</h3><div>The purpose of this prospective clinical study was to evaluate correlations between different implant positions and crestal bone loss and between interimplant distance and the crestal bone loss in patients with 2IMOs with immediate loading protocols at 1-year follow-up.</div></div><div><h3>Material and methods</h3><div>A total of 24 participants (13 men, 11 women, mean ±standard deviation age 63.25 ±10.76 years) were treated with 2IMOs (48 Ti-Zr implants) by a single operator between August 2015 and October 2020. The implant diameters (3.3 mm or 4.1 mm) and lengths (10 mm or 12 mm) were selected based on the crestal bone width, and the implants were placed, if possible, in the canine regions. Implant positions and interimplant distance (mm) were measured intraorally with dividers. Prefabricated mandibular dentures were immediately loaded with the LOCATOR-attachments by using a direct intraoral pickup procedure. Crestal bone-level changes were measured with a software program on the mesial and distal sides of each implant from periapical radiographs made with a paralleling technique (at baseline and 1-year follow-up). The measurement values were normalized. The Spearman rho correlation test and paired samples <em>t</em> tests were used for data analysis (α=.05).</div></div><div><h3>Results</h3><div>The mean ±standard deviation position of the implants from the midline was 8.78 ±2.25 mm (9.00 ±2.22 mm right side, 8.56 ±2.31 mm left side), and the mean interimplant distance was 16.94 ±4.03 mm. At 1-year follow-up, the mean ±standard deviation crestal bone loss was 0.50 ±0.47 mm (n=48) (0.57 ±0.65 mm mesial, 0.43 ±0.53 mm distal). The mean ±standard deviation crestal bone loss was 0.46 ±0.4 mm with Ø3.3-mm implants (n=42) and 0.9 ±0.8 mm with Ø4.1-mm implants (n=6) (<em>P</em>=.005). Implant positions were negatively correlated (rs=-0.37) with the crestal bone loss, and the correlation was significant (<em>P</em>=.009). Interimplant distances were also negatively correlated with crestal bone loss (rs=-0.60; <em>P</em>=.002). Bone loss on the mesial side was positively correlated with that on the distal side rs=0.20; however, the correlation was not significant (<em>P</em>=.16).</div></div><div><h3>Conclusions</h3><div>A weak and negative correlation was found between the implant position from the midline and the crestal bone loss and also between the interimplant distance and crestal bone loss in patients provided with 2IMOs with immediate loading protocols.</div></div>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Correlation of implant position and crestal bone loss in 2-implant mandibular overdentures with immediate loading protocols: A prospective clinical study\",\"authors\":\"\",\"doi\":\"10.1016/j.prosdent.2022.09.007\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Statement of problem</h3><div><span>The 2-implant mandibular overdenture (2IMO) is a popular treatment for patients with an </span>edentulous mandible, but information on the effect of the optimum implant position on the peri-implant crestal bone level with immediate loading protocols is lacking.</div></div><div><h3>Purpose</h3><div>The purpose of this prospective clinical study was to evaluate correlations between different implant positions and crestal bone loss and between interimplant distance and the crestal bone loss in patients with 2IMOs with immediate loading protocols at 1-year follow-up.</div></div><div><h3>Material and methods</h3><div>A total of 24 participants (13 men, 11 women, mean ±standard deviation age 63.25 ±10.76 years) were treated with 2IMOs (48 Ti-Zr implants) by a single operator between August 2015 and October 2020. The implant diameters (3.3 mm or 4.1 mm) and lengths (10 mm or 12 mm) were selected based on the crestal bone width, and the implants were placed, if possible, in the canine regions. Implant positions and interimplant distance (mm) were measured intraorally with dividers. Prefabricated mandibular dentures were immediately loaded with the LOCATOR-attachments by using a direct intraoral pickup procedure. Crestal bone-level changes were measured with a software program on the mesial and distal sides of each implant from periapical radiographs made with a paralleling technique (at baseline and 1-year follow-up). The measurement values were normalized. The Spearman rho correlation test and paired samples <em>t</em> tests were used for data analysis (α=.05).</div></div><div><h3>Results</h3><div>The mean ±standard deviation position of the implants from the midline was 8.78 ±2.25 mm (9.00 ±2.22 mm right side, 8.56 ±2.31 mm left side), and the mean interimplant distance was 16.94 ±4.03 mm. At 1-year follow-up, the mean ±standard deviation crestal bone loss was 0.50 ±0.47 mm (n=48) (0.57 ±0.65 mm mesial, 0.43 ±0.53 mm distal). The mean ±standard deviation crestal bone loss was 0.46 ±0.4 mm with Ø3.3-mm implants (n=42) and 0.9 ±0.8 mm with Ø4.1-mm implants (n=6) (<em>P</em>=.005). Implant positions were negatively correlated (rs=-0.37) with the crestal bone loss, and the correlation was significant (<em>P</em>=.009). Interimplant distances were also negatively correlated with crestal bone loss (rs=-0.60; <em>P</em>=.002). Bone loss on the mesial side was positively correlated with that on the distal side rs=0.20; however, the correlation was not significant (<em>P</em>=.16).</div></div><div><h3>Conclusions</h3><div>A weak and negative correlation was found between the implant position from the midline and the crestal bone loss and also between the interimplant distance and crestal bone loss in patients provided with 2IMOs with immediate loading protocols.</div></div>\",\"PeriodicalId\":16866,\"journal\":{\"name\":\"Journal of Prosthetic Dentistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Prosthetic Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0022391322006102\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0022391322006102","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

问题简介:双种植体下颌覆盖义齿(2IMO)是治疗下颌无牙颌患者的一种常用方法,但目前还缺乏有关即刻加载方案下最佳种植体位置对种植体周围骨嵴水平影响的信息。目的:本前瞻性临床研究旨在评估即刻加载方案下2IMO患者不同种植体位置与骨嵴骨质流失之间的相关性,以及1年随访时临时种植体间距与骨嵴骨质流失之间的相关性:在 2015 年 8 月至 2020 年 10 月期间,共有 24 名参与者(13 名男性,11 名女性,平均 ± 标准差年龄为 63.25 ±10.76 岁)接受了 2IMOs 治疗(48 个钛锌种植体)。种植体直径(3.3 毫米或 4.1 毫米)和长度(10 毫米或 12 毫米)根据牙槽骨宽度选择,种植体尽可能植入犬齿区域。种植体位置和临时种植体间距(毫米)用分隔器在口腔内测量。采用口内直接取戴法,将预制的下颌假牙与 LOCATOR-attachments 安装在一起。使用软件程序通过平行技术拍摄的根尖周X光片(基线和1年随访)测量每个种植体的中远端嵴骨水平变化。测量值已归一化。数据分析采用 Spearman rho 相关性检验和配对样本 t 检验(α=.05):种植体距离中线的平均±标准偏差位置为 8.78 ±2.25 mm(右侧为 9.00 ±2.22 mm,左侧为 8.56 ±2.31 mm),平均临时种植距离为 16.94 ±4.03 mm。随访1年时,平均±标准偏差骨嵴骨质流失为0.50±0.47毫米(48人)(中侧0.57±0.65毫米,远侧0.43±0.53毫米)。直径 3.3 毫米种植体的平均±标准偏差骨嵴损失为 0.46 ±0.4 毫米(42 人),直径 4.1 毫米种植体的平均±标准偏差骨嵴损失为 0.9 ±0.8 毫米(6 人)(P=0.005)。种植体位置与骨嵴骨质流失呈负相关(rs=-0.37),相关性显著(P=.009)。种植体间距也与骨嵴骨质流失呈负相关(rs=-0.60;P=.002)。中侧的骨质流失与远侧的骨质流失呈正相关,rs=0.20;但相关性不显著(P=.16):结论:在采用即刻加载方案的 2IMOs 患者中,种植体距中线的位置与骨嵴骨质流失之间以及临时种植体间距与骨嵴骨质流失之间存在微弱的负相关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Correlation of implant position and crestal bone loss in 2-implant mandibular overdentures with immediate loading protocols: A prospective clinical study

Statement of problem

The 2-implant mandibular overdenture (2IMO) is a popular treatment for patients with an edentulous mandible, but information on the effect of the optimum implant position on the peri-implant crestal bone level with immediate loading protocols is lacking.

Purpose

The purpose of this prospective clinical study was to evaluate correlations between different implant positions and crestal bone loss and between interimplant distance and the crestal bone loss in patients with 2IMOs with immediate loading protocols at 1-year follow-up.

Material and methods

A total of 24 participants (13 men, 11 women, mean ±standard deviation age 63.25 ±10.76 years) were treated with 2IMOs (48 Ti-Zr implants) by a single operator between August 2015 and October 2020. The implant diameters (3.3 mm or 4.1 mm) and lengths (10 mm or 12 mm) were selected based on the crestal bone width, and the implants were placed, if possible, in the canine regions. Implant positions and interimplant distance (mm) were measured intraorally with dividers. Prefabricated mandibular dentures were immediately loaded with the LOCATOR-attachments by using a direct intraoral pickup procedure. Crestal bone-level changes were measured with a software program on the mesial and distal sides of each implant from periapical radiographs made with a paralleling technique (at baseline and 1-year follow-up). The measurement values were normalized. The Spearman rho correlation test and paired samples t tests were used for data analysis (α=.05).

Results

The mean ±standard deviation position of the implants from the midline was 8.78 ±2.25 mm (9.00 ±2.22 mm right side, 8.56 ±2.31 mm left side), and the mean interimplant distance was 16.94 ±4.03 mm. At 1-year follow-up, the mean ±standard deviation crestal bone loss was 0.50 ±0.47 mm (n=48) (0.57 ±0.65 mm mesial, 0.43 ±0.53 mm distal). The mean ±standard deviation crestal bone loss was 0.46 ±0.4 mm with Ø3.3-mm implants (n=42) and 0.9 ±0.8 mm with Ø4.1-mm implants (n=6) (P=.005). Implant positions were negatively correlated (rs=-0.37) with the crestal bone loss, and the correlation was significant (P=.009). Interimplant distances were also negatively correlated with crestal bone loss (rs=-0.60; P=.002). Bone loss on the mesial side was positively correlated with that on the distal side rs=0.20; however, the correlation was not significant (P=.16).

Conclusions

A weak and negative correlation was found between the implant position from the midline and the crestal bone loss and also between the interimplant distance and crestal bone loss in patients provided with 2IMOs with immediate loading protocols.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Prosthetic Dentistry
Journal of Prosthetic Dentistry 医学-牙科与口腔外科
CiteScore
7.00
自引率
13.00%
发文量
599
审稿时长
69 days
期刊介绍: The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信