使用气相色谱-质谱法对临床相关生物体液中肠道衍生短链脂肪酸进行简单、高通量的测量

IF 3.1 4区 医学 Q2 MEDICAL LABORATORY TECHNOLOGY
Joshua T Bain , Maarten W Taal , Nicholas M Selby , James C Reynolds , Liam M Heaney
{"title":"使用气相色谱-质谱法对临床相关生物体液中肠道衍生短链脂肪酸进行简单、高通量的测量","authors":"Joshua T Bain ,&nbsp;Maarten W Taal ,&nbsp;Nicholas M Selby ,&nbsp;James C Reynolds ,&nbsp;Liam M Heaney","doi":"10.1016/j.jmsacl.2022.07.002","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>The quantitative measurement of circulating gut bacteria-derived metabolites has increased in recent years due to their associations with health and disease. While much of the previous attention has been placed on metabolites considered as deleterious to health, a shift to the investigation of short-chain fatty acids (SCFAs) as potential health promotors has been observed.</p></div><div><h3>Objectives</h3><p>To develop a simple, high-throughput and quantitative assay to measure gut-derived SCFAs in clinically relevant biofluids using gas chromatography-mass spectrometry (GC–MS).</p></div><div><h3>Methods</h3><p>A short (7.5 min) GC–MS assay was optimized for measurement of seven straight- and branched-chain SCFAs and their deuterated isotopes using a wax-based column for analysis without prior derivatization. The assay was validated using routine criteria to assess precision, accuracy, matrix effects, recovery, and extraction reproducibility. Assay applicability was tested in cohorts of healthy individuals and kidney disease patients.</p></div><div><h3>Results</h3><p>The assay was demonstrated to be precise, accurate and reproducible with acceptable levels of matrix effect and analyte recovery. Lower limits of detection and quantitation were in the low ng/mL range. An investigation into different blood collection tube chemistries demonstrated that lithium heparin plasma and serum clotting activator tubes are recommended for use in future cross-study comparisons. Kidney disease patient analyses demonstrated variable differences across SCFAs when comparing hemodialysis to earlier stages of chronic kidney disease, demonstrating the suitability of the assay for translation to clinical analyses.</p></div><div><h3>Conclusion</h3><p>The assay has been validated and identified as reliable for use in larger-scale studies for the analysis of SCFAs in human plasma and serum.</p></div>","PeriodicalId":52406,"journal":{"name":"Journal of Mass Spectrometry and Advances in the Clinical Lab","volume":"25 ","pages":"Pages 36-43"},"PeriodicalIF":3.1000,"publicationDate":"2022-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9304766/pdf/","citationCount":"0","resultStr":"{\"title\":\"Simple, high-throughput measurement of gut-derived short-chain fatty acids in clinically relevant biofluids using gas chromatography-mass spectrometry\",\"authors\":\"Joshua T Bain ,&nbsp;Maarten W Taal ,&nbsp;Nicholas M Selby ,&nbsp;James C Reynolds ,&nbsp;Liam M Heaney\",\"doi\":\"10.1016/j.jmsacl.2022.07.002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Introduction</h3><p>The quantitative measurement of circulating gut bacteria-derived metabolites has increased in recent years due to their associations with health and disease. While much of the previous attention has been placed on metabolites considered as deleterious to health, a shift to the investigation of short-chain fatty acids (SCFAs) as potential health promotors has been observed.</p></div><div><h3>Objectives</h3><p>To develop a simple, high-throughput and quantitative assay to measure gut-derived SCFAs in clinically relevant biofluids using gas chromatography-mass spectrometry (GC–MS).</p></div><div><h3>Methods</h3><p>A short (7.5 min) GC–MS assay was optimized for measurement of seven straight- and branched-chain SCFAs and their deuterated isotopes using a wax-based column for analysis without prior derivatization. The assay was validated using routine criteria to assess precision, accuracy, matrix effects, recovery, and extraction reproducibility. Assay applicability was tested in cohorts of healthy individuals and kidney disease patients.</p></div><div><h3>Results</h3><p>The assay was demonstrated to be precise, accurate and reproducible with acceptable levels of matrix effect and analyte recovery. Lower limits of detection and quantitation were in the low ng/mL range. An investigation into different blood collection tube chemistries demonstrated that lithium heparin plasma and serum clotting activator tubes are recommended for use in future cross-study comparisons. Kidney disease patient analyses demonstrated variable differences across SCFAs when comparing hemodialysis to earlier stages of chronic kidney disease, demonstrating the suitability of the assay for translation to clinical analyses.</p></div><div><h3>Conclusion</h3><p>The assay has been validated and identified as reliable for use in larger-scale studies for the analysis of SCFAs in human plasma and serum.</p></div>\",\"PeriodicalId\":52406,\"journal\":{\"name\":\"Journal of Mass Spectrometry and Advances in the Clinical Lab\",\"volume\":\"25 \",\"pages\":\"Pages 36-43\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2022-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9304766/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Mass Spectrometry and Advances in the Clinical Lab\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2667145X22000207\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Mass Spectrometry and Advances in the Clinical Lab","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2667145X22000207","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

近年来,由于循环肠道细菌衍生代谢物与健康和疾病的相关性,其定量测量有所增加。虽然以前的大部分注意力都放在被认为对健康有害的代谢物上,但已经观察到短链脂肪酸(SCFAs)作为潜在的健康促进剂的研究转变。目的建立一种简单、高通量、定量的气相色谱-质谱(GC-MS)检测临床相关生物体液中肠源性SCFAs的方法。方法采用蜡基色谱柱对7种直链和支链SCFAs及其氘化同位素进行短(7.5 min)气相色谱-质谱分析,无需事先衍生化。使用常规标准对该方法进行验证,以评估精密度、准确度、基质效应、回收率和提取重现性。在健康个体和肾脏疾病患者的队列中测试了该方法的适用性。结果该方法精密度高,准确度高,重现性好,基质效应良好,分析物回收率高。检测和定量下限均在低ng/mL范围内。一项对不同采血管化学成分的调查表明,锂肝素血浆和血清凝血激活剂管被推荐用于未来的交叉研究比较。肾脏疾病患者分析表明,当比较血液透析与早期慢性肾脏疾病时,scfa之间存在可变差异,证明了该检测方法转化为临床分析的适用性。结论:该方法已被验证并确定为可靠的,可用于分析人血浆和血清中SCFAs的大规模研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Simple, high-throughput measurement of gut-derived short-chain fatty acids in clinically relevant biofluids using gas chromatography-mass spectrometry

Simple, high-throughput measurement of gut-derived short-chain fatty acids in clinically relevant biofluids using gas chromatography-mass spectrometry

Simple, high-throughput measurement of gut-derived short-chain fatty acids in clinically relevant biofluids using gas chromatography-mass spectrometry

Simple, high-throughput measurement of gut-derived short-chain fatty acids in clinically relevant biofluids using gas chromatography-mass spectrometry

Introduction

The quantitative measurement of circulating gut bacteria-derived metabolites has increased in recent years due to their associations with health and disease. While much of the previous attention has been placed on metabolites considered as deleterious to health, a shift to the investigation of short-chain fatty acids (SCFAs) as potential health promotors has been observed.

Objectives

To develop a simple, high-throughput and quantitative assay to measure gut-derived SCFAs in clinically relevant biofluids using gas chromatography-mass spectrometry (GC–MS).

Methods

A short (7.5 min) GC–MS assay was optimized for measurement of seven straight- and branched-chain SCFAs and their deuterated isotopes using a wax-based column for analysis without prior derivatization. The assay was validated using routine criteria to assess precision, accuracy, matrix effects, recovery, and extraction reproducibility. Assay applicability was tested in cohorts of healthy individuals and kidney disease patients.

Results

The assay was demonstrated to be precise, accurate and reproducible with acceptable levels of matrix effect and analyte recovery. Lower limits of detection and quantitation were in the low ng/mL range. An investigation into different blood collection tube chemistries demonstrated that lithium heparin plasma and serum clotting activator tubes are recommended for use in future cross-study comparisons. Kidney disease patient analyses demonstrated variable differences across SCFAs when comparing hemodialysis to earlier stages of chronic kidney disease, demonstrating the suitability of the assay for translation to clinical analyses.

Conclusion

The assay has been validated and identified as reliable for use in larger-scale studies for the analysis of SCFAs in human plasma and serum.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Mass Spectrometry and Advances in the Clinical Lab
Journal of Mass Spectrometry and Advances in the Clinical Lab Health Professions-Medical Laboratory Technology
CiteScore
4.30
自引率
18.20%
发文量
41
审稿时长
81 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信