结合3种传统触诊技术的C7棘突触诊方案的准确性和可靠性

IF 1.2 4区 医学 Q4 HEALTH CARE SCIENCES & SERVICES
Priscila M.N.M. Albuquerque MSc , Ericka P.C. Da Silva , Thania M. de S. Melo MSc , Eduardo J.N. Montenegro PT , Daniella A. de Oliveira PT , Marcelo R. Guerino PT , Gisela R. De Siqueira PhD
{"title":"结合3种传统触诊技术的C7棘突触诊方案的准确性和可靠性","authors":"Priscila M.N.M. Albuquerque MSc ,&nbsp;Ericka P.C. Da Silva ,&nbsp;Thania M. de S. Melo MSc ,&nbsp;Eduardo J.N. Montenegro PT ,&nbsp;Daniella A. de Oliveira PT ,&nbsp;Marcelo R. Guerino PT ,&nbsp;Gisela R. De Siqueira PhD","doi":"10.1016/j.jmpt.2022.06.001","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><p><span>The purpose of this study was to determine the accuracy and intrarater reliability of a palpatory protocol based on a combination of 3 palpatory methods to identify both the C7 </span>spinous process (C7 SP) and the factors that affect the errors and inaccuracy of palpation.</p></div><div><h3>Methods</h3><p><span>Twenty-five women between the ages of 18 and 60 years were submitted to a palpation protocol of the C7 SP, and a radiopaque marker was fixed on the skin at the possible location of the vertebrae<span>. A radiograph and a photograph<span><span> of the cervical spine were obtained in the same posture by a first rater. A second rater performed the same palpation protocol and took a second photograph. The accuracy and measurement error of the palpation protocol of C7 SP were assessed through radiographic images. The inter-rater reliability was estimated by the interclass </span>correlation coefficient and assessed using photographs of each rater. The Pearson's correlation coefficients (</span></span></span><em>r</em><span>), the Fisher exact test, and the χ</span><sup>2</sup> test were used to identify the factors associated with the error and inaccuracy of palpation.</p></div><div><h3>Results</h3><p>Accuracy of the C7 palpation was 76% with excellent reliability (interclass correlation coefficient = 0.99). There was a moderate correlation between weight and the measurement of palpation error (<em>r</em> = –0.6; <em>P</em> = .003). One hundred percent of inaccuracy palpation was related to the increased soft-tissue thickness (<em>P =</em> .005) in the cervical region.</p></div><div><h3>Conclusion</h3><p>The palpation protocol described in this study was accurate and presented excellent reliability in identifying the C7 SP. Increased weight and dorsocervical fat pad were associated to error and palpation inaccuracy, respectively.</p></div>","PeriodicalId":16132,"journal":{"name":"Journal of Manipulative and Physiological Therapeutics","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2022-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Inter-rater Accuracy and Reliability of a Palpation Protocol of the C7 Spinous Process Comprising a Combination of 3 Traditional Palpation Techniques\",\"authors\":\"Priscila M.N.M. Albuquerque MSc ,&nbsp;Ericka P.C. Da Silva ,&nbsp;Thania M. de S. Melo MSc ,&nbsp;Eduardo J.N. Montenegro PT ,&nbsp;Daniella A. de Oliveira PT ,&nbsp;Marcelo R. Guerino PT ,&nbsp;Gisela R. De Siqueira PhD\",\"doi\":\"10.1016/j.jmpt.2022.06.001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objective</h3><p><span>The purpose of this study was to determine the accuracy and intrarater reliability of a palpatory protocol based on a combination of 3 palpatory methods to identify both the C7 </span>spinous process (C7 SP) and the factors that affect the errors and inaccuracy of palpation.</p></div><div><h3>Methods</h3><p><span>Twenty-five women between the ages of 18 and 60 years were submitted to a palpation protocol of the C7 SP, and a radiopaque marker was fixed on the skin at the possible location of the vertebrae<span>. A radiograph and a photograph<span><span> of the cervical spine were obtained in the same posture by a first rater. A second rater performed the same palpation protocol and took a second photograph. The accuracy and measurement error of the palpation protocol of C7 SP were assessed through radiographic images. The inter-rater reliability was estimated by the interclass </span>correlation coefficient and assessed using photographs of each rater. The Pearson's correlation coefficients (</span></span></span><em>r</em><span>), the Fisher exact test, and the χ</span><sup>2</sup> test were used to identify the factors associated with the error and inaccuracy of palpation.</p></div><div><h3>Results</h3><p>Accuracy of the C7 palpation was 76% with excellent reliability (interclass correlation coefficient = 0.99). There was a moderate correlation between weight and the measurement of palpation error (<em>r</em> = –0.6; <em>P</em> = .003). One hundred percent of inaccuracy palpation was related to the increased soft-tissue thickness (<em>P =</em> .005) in the cervical region.</p></div><div><h3>Conclusion</h3><p>The palpation protocol described in this study was accurate and presented excellent reliability in identifying the C7 SP. Increased weight and dorsocervical fat pad were associated to error and palpation inaccuracy, respectively.</p></div>\",\"PeriodicalId\":16132,\"journal\":{\"name\":\"Journal of Manipulative and Physiological Therapeutics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2022-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Manipulative and Physiological Therapeutics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0161475422000446\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"HEALTH CARE SCIENCES & SERVICES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Manipulative and Physiological Therapeutics","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0161475422000446","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
引用次数: 0

摘要

目的本研究的目的是确定基于3种触诊方法组合的触诊方案的准确性和内部可靠性,以识别C7棘突(C7 SP)以及影响触诊错误和不准确的因素。方法选取25例年龄在18 ~ 60岁的女性进行C7 SP触诊,并在椎骨可能位置的皮肤上固定不透射线标记物。颈椎的x线片和照片是由第一人称以相同的姿势获得的。另一名志愿者执行了同样的触诊程序,并拍了第二张照片。通过x线影像评估C7 SP触诊方案的准确性和测量误差。用类间相关系数估计类间信度,并利用每个评价者的照片进行评价。采用Pearson相关系数(r)、Fisher精确检验和χ2检验确定与触诊误差和不准确相关的因素。结果C7触诊准确率为76%,信度极佳(类间相关系数= 0.99)。体重与触诊误差测量之间存在中度相关性(r = -0.6;p = .003)。触诊不准确的100%与颈部软组织厚度增加有关(P = 0.005)。结论本研究中描述的触诊方案是准确的,并且在识别C7 SP方面具有出色的可靠性。体重增加和颈背脂肪垫分别与触诊错误和不准确相关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Inter-rater Accuracy and Reliability of a Palpation Protocol of the C7 Spinous Process Comprising a Combination of 3 Traditional Palpation Techniques

Objective

The purpose of this study was to determine the accuracy and intrarater reliability of a palpatory protocol based on a combination of 3 palpatory methods to identify both the C7 spinous process (C7 SP) and the factors that affect the errors and inaccuracy of palpation.

Methods

Twenty-five women between the ages of 18 and 60 years were submitted to a palpation protocol of the C7 SP, and a radiopaque marker was fixed on the skin at the possible location of the vertebrae. A radiograph and a photograph of the cervical spine were obtained in the same posture by a first rater. A second rater performed the same palpation protocol and took a second photograph. The accuracy and measurement error of the palpation protocol of C7 SP were assessed through radiographic images. The inter-rater reliability was estimated by the interclass correlation coefficient and assessed using photographs of each rater. The Pearson's correlation coefficients (r), the Fisher exact test, and the χ2 test were used to identify the factors associated with the error and inaccuracy of palpation.

Results

Accuracy of the C7 palpation was 76% with excellent reliability (interclass correlation coefficient = 0.99). There was a moderate correlation between weight and the measurement of palpation error (r = –0.6; P = .003). One hundred percent of inaccuracy palpation was related to the increased soft-tissue thickness (P = .005) in the cervical region.

Conclusion

The palpation protocol described in this study was accurate and presented excellent reliability in identifying the C7 SP. Increased weight and dorsocervical fat pad were associated to error and palpation inaccuracy, respectively.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.00
自引率
7.70%
发文量
63
审稿时长
29 weeks
期刊介绍: The Journal of Manipulative and Physiological Therapeutics (JMPT) is an international and interdisciplinary journal dedicated to the advancement of conservative health care principles and practices. The JMPT is the premier biomedical publication in the chiropractic profession and publishes peer reviewed, research articles and the Journal''s editorial board includes leading researchers from around the world. The Journal publishes original primary research and review articles of the highest quality in relevant topic areas. The JMPT addresses practitioners and researchers needs by adding to their clinical and basic science knowledge and by informing them about relevant issues that influence health care practices.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信