Priscila M.N.M. Albuquerque MSc , Ericka P.C. Da Silva , Thania M. de S. Melo MSc , Eduardo J.N. Montenegro PT , Daniella A. de Oliveira PT , Marcelo R. Guerino PT , Gisela R. De Siqueira PhD
{"title":"结合3种传统触诊技术的C7棘突触诊方案的准确性和可靠性","authors":"Priscila M.N.M. Albuquerque MSc , Ericka P.C. Da Silva , Thania M. de S. Melo MSc , Eduardo J.N. Montenegro PT , Daniella A. de Oliveira PT , Marcelo R. Guerino PT , Gisela R. De Siqueira PhD","doi":"10.1016/j.jmpt.2022.06.001","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><p><span>The purpose of this study was to determine the accuracy and intrarater reliability of a palpatory protocol based on a combination of 3 palpatory methods to identify both the C7 </span>spinous process (C7 SP) and the factors that affect the errors and inaccuracy of palpation.</p></div><div><h3>Methods</h3><p><span>Twenty-five women between the ages of 18 and 60 years were submitted to a palpation protocol of the C7 SP, and a radiopaque marker was fixed on the skin at the possible location of the vertebrae<span>. A radiograph and a photograph<span><span> of the cervical spine were obtained in the same posture by a first rater. A second rater performed the same palpation protocol and took a second photograph. The accuracy and measurement error of the palpation protocol of C7 SP were assessed through radiographic images. The inter-rater reliability was estimated by the interclass </span>correlation coefficient and assessed using photographs of each rater. The Pearson's correlation coefficients (</span></span></span><em>r</em><span>), the Fisher exact test, and the χ</span><sup>2</sup> test were used to identify the factors associated with the error and inaccuracy of palpation.</p></div><div><h3>Results</h3><p>Accuracy of the C7 palpation was 76% with excellent reliability (interclass correlation coefficient = 0.99). There was a moderate correlation between weight and the measurement of palpation error (<em>r</em> = –0.6; <em>P</em> = .003). One hundred percent of inaccuracy palpation was related to the increased soft-tissue thickness (<em>P =</em> .005) in the cervical region.</p></div><div><h3>Conclusion</h3><p>The palpation protocol described in this study was accurate and presented excellent reliability in identifying the C7 SP. Increased weight and dorsocervical fat pad were associated to error and palpation inaccuracy, respectively.</p></div>","PeriodicalId":16132,"journal":{"name":"Journal of Manipulative and Physiological Therapeutics","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2022-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Inter-rater Accuracy and Reliability of a Palpation Protocol of the C7 Spinous Process Comprising a Combination of 3 Traditional Palpation Techniques\",\"authors\":\"Priscila M.N.M. Albuquerque MSc , Ericka P.C. Da Silva , Thania M. de S. Melo MSc , Eduardo J.N. Montenegro PT , Daniella A. de Oliveira PT , Marcelo R. Guerino PT , Gisela R. De Siqueira PhD\",\"doi\":\"10.1016/j.jmpt.2022.06.001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objective</h3><p><span>The purpose of this study was to determine the accuracy and intrarater reliability of a palpatory protocol based on a combination of 3 palpatory methods to identify both the C7 </span>spinous process (C7 SP) and the factors that affect the errors and inaccuracy of palpation.</p></div><div><h3>Methods</h3><p><span>Twenty-five women between the ages of 18 and 60 years were submitted to a palpation protocol of the C7 SP, and a radiopaque marker was fixed on the skin at the possible location of the vertebrae<span>. A radiograph and a photograph<span><span> of the cervical spine were obtained in the same posture by a first rater. A second rater performed the same palpation protocol and took a second photograph. The accuracy and measurement error of the palpation protocol of C7 SP were assessed through radiographic images. The inter-rater reliability was estimated by the interclass </span>correlation coefficient and assessed using photographs of each rater. The Pearson's correlation coefficients (</span></span></span><em>r</em><span>), the Fisher exact test, and the χ</span><sup>2</sup> test were used to identify the factors associated with the error and inaccuracy of palpation.</p></div><div><h3>Results</h3><p>Accuracy of the C7 palpation was 76% with excellent reliability (interclass correlation coefficient = 0.99). There was a moderate correlation between weight and the measurement of palpation error (<em>r</em> = –0.6; <em>P</em> = .003). One hundred percent of inaccuracy palpation was related to the increased soft-tissue thickness (<em>P =</em> .005) in the cervical region.</p></div><div><h3>Conclusion</h3><p>The palpation protocol described in this study was accurate and presented excellent reliability in identifying the C7 SP. Increased weight and dorsocervical fat pad were associated to error and palpation inaccuracy, respectively.</p></div>\",\"PeriodicalId\":16132,\"journal\":{\"name\":\"Journal of Manipulative and Physiological Therapeutics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2022-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Manipulative and Physiological Therapeutics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0161475422000446\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"HEALTH CARE SCIENCES & SERVICES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Manipulative and Physiological Therapeutics","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0161475422000446","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
Inter-rater Accuracy and Reliability of a Palpation Protocol of the C7 Spinous Process Comprising a Combination of 3 Traditional Palpation Techniques
Objective
The purpose of this study was to determine the accuracy and intrarater reliability of a palpatory protocol based on a combination of 3 palpatory methods to identify both the C7 spinous process (C7 SP) and the factors that affect the errors and inaccuracy of palpation.
Methods
Twenty-five women between the ages of 18 and 60 years were submitted to a palpation protocol of the C7 SP, and a radiopaque marker was fixed on the skin at the possible location of the vertebrae. A radiograph and a photograph of the cervical spine were obtained in the same posture by a first rater. A second rater performed the same palpation protocol and took a second photograph. The accuracy and measurement error of the palpation protocol of C7 SP were assessed through radiographic images. The inter-rater reliability was estimated by the interclass correlation coefficient and assessed using photographs of each rater. The Pearson's correlation coefficients (r), the Fisher exact test, and the χ2 test were used to identify the factors associated with the error and inaccuracy of palpation.
Results
Accuracy of the C7 palpation was 76% with excellent reliability (interclass correlation coefficient = 0.99). There was a moderate correlation between weight and the measurement of palpation error (r = –0.6; P = .003). One hundred percent of inaccuracy palpation was related to the increased soft-tissue thickness (P = .005) in the cervical region.
Conclusion
The palpation protocol described in this study was accurate and presented excellent reliability in identifying the C7 SP. Increased weight and dorsocervical fat pad were associated to error and palpation inaccuracy, respectively.
期刊介绍:
The Journal of Manipulative and Physiological Therapeutics (JMPT) is an international and interdisciplinary journal dedicated to the advancement of conservative health care principles and practices. The JMPT is the premier biomedical publication in the chiropractic profession and publishes peer reviewed, research articles and the Journal''s editorial board includes leading researchers from around the world.
The Journal publishes original primary research and review articles of the highest quality in relevant topic areas. The JMPT addresses practitioners and researchers needs by adding to their clinical and basic science knowledge and by informing them about relevant issues that influence health care practices.