使用双注射器无菌系统的MSK吸入/注射过程消除医源性感染的风险。

IF 2.8 3区 医学 Q1 Pharmacology, Toxicology and Pharmaceutics
Therapeutics and Clinical Risk Management Pub Date : 2022-10-29 eCollection Date: 2022-01-01 DOI:10.2147/TCRM.S372676
Adrian Emil Lazarescu, Bogdan Gheorghe Hogea, Bogdan Corneliu Andor, Alina Totorean, Dan Grigore Cojocaru, Marius Negru, Laura A Bolintineanu, Jenel Marian Patrascu Jnr, Liviu C Misca, Mihai A Sandesc, Jenel Marian Patrascu Snr
{"title":"使用双注射器无菌系统的MSK吸入/注射过程消除医源性感染的风险。","authors":"Adrian Emil Lazarescu,&nbsp;Bogdan Gheorghe Hogea,&nbsp;Bogdan Corneliu Andor,&nbsp;Alina Totorean,&nbsp;Dan Grigore Cojocaru,&nbsp;Marius Negru,&nbsp;Laura A Bolintineanu,&nbsp;Jenel Marian Patrascu Jnr,&nbsp;Liviu C Misca,&nbsp;Mihai A Sandesc,&nbsp;Jenel Marian Patrascu Snr","doi":"10.2147/TCRM.S372676","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Diverse musculo-skeletal pathology can be treated conservatively by different types of injections and in most cases, results are significantly better if the existing inflammatory fluid is aspirated prior to injection of medication solutions. The present study analyses an original technique which uses infusion therapy accessories to create two types of closed sterile double syringe systems, and compares the benefits of using such a system in aspiration/injection procedures to classic aspiration injection technique that implies changing and connecting multiple syringes to the same needle, thus increasing the risk for septic complications. The aim of the present study is to minimize therapeutic risk of iatrogenic septic complications during aspiration/injection procedures.</p><p><strong>Methods: </strong>1024 patients underwent aspiration/injection procedures in our clinic using the double syringe system between 2015 and 2020. During the early stages of the study, the second type of assembly was rendered impractical so the study continued with analyzing a single type of double syringe system using a three way infusion therapy device which is readily available, and allows the assembly of a closed sterile system with a single, two-step procedure technique. Iatrogenic local septic complications were followed by means of a six week clinical follow-up evaluation with additional investigations only if necessary.</p><p><strong>Results: </strong>In 1024 procedures we report 0% incidence of iatrogenic septic complications, or other types of complications and recommend this technique in a vast array of rheumatic, orthopedic or traumatic conditions that require aspiration/injection procedures.</p><p><strong>Discussion: </strong>The double syringe system is practical, easy to use, it completely eliminates the risk of iatrogenic infection due to manipulation errors, and significantly simplifies the technique for sonography guided aspiration/injection procedures for musculo-skeletal pathology.</p>","PeriodicalId":22977,"journal":{"name":"Therapeutics and Clinical Risk Management","volume":null,"pages":null},"PeriodicalIF":2.8000,"publicationDate":"2022-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/87/75/tcrm-18-1029.PMC9628697.pdf","citationCount":"1","resultStr":"{\"title\":\"Using a Double Syringe Sterile System for MSK Aspiration/Injection Procedures Eliminates Risk of Iatrogenic Infection.\",\"authors\":\"Adrian Emil Lazarescu,&nbsp;Bogdan Gheorghe Hogea,&nbsp;Bogdan Corneliu Andor,&nbsp;Alina Totorean,&nbsp;Dan Grigore Cojocaru,&nbsp;Marius Negru,&nbsp;Laura A Bolintineanu,&nbsp;Jenel Marian Patrascu Jnr,&nbsp;Liviu C Misca,&nbsp;Mihai A Sandesc,&nbsp;Jenel Marian Patrascu Snr\",\"doi\":\"10.2147/TCRM.S372676\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Diverse musculo-skeletal pathology can be treated conservatively by different types of injections and in most cases, results are significantly better if the existing inflammatory fluid is aspirated prior to injection of medication solutions. The present study analyses an original technique which uses infusion therapy accessories to create two types of closed sterile double syringe systems, and compares the benefits of using such a system in aspiration/injection procedures to classic aspiration injection technique that implies changing and connecting multiple syringes to the same needle, thus increasing the risk for septic complications. The aim of the present study is to minimize therapeutic risk of iatrogenic septic complications during aspiration/injection procedures.</p><p><strong>Methods: </strong>1024 patients underwent aspiration/injection procedures in our clinic using the double syringe system between 2015 and 2020. During the early stages of the study, the second type of assembly was rendered impractical so the study continued with analyzing a single type of double syringe system using a three way infusion therapy device which is readily available, and allows the assembly of a closed sterile system with a single, two-step procedure technique. Iatrogenic local septic complications were followed by means of a six week clinical follow-up evaluation with additional investigations only if necessary.</p><p><strong>Results: </strong>In 1024 procedures we report 0% incidence of iatrogenic septic complications, or other types of complications and recommend this technique in a vast array of rheumatic, orthopedic or traumatic conditions that require aspiration/injection procedures.</p><p><strong>Discussion: </strong>The double syringe system is practical, easy to use, it completely eliminates the risk of iatrogenic infection due to manipulation errors, and significantly simplifies the technique for sonography guided aspiration/injection procedures for musculo-skeletal pathology.</p>\",\"PeriodicalId\":22977,\"journal\":{\"name\":\"Therapeutics and Clinical Risk Management\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2022-10-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/87/75/tcrm-18-1029.PMC9628697.pdf\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Therapeutics and Clinical Risk Management\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2147/TCRM.S372676\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q1\",\"JCRName\":\"Pharmacology, Toxicology and Pharmaceutics\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Therapeutics and Clinical Risk Management","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2147/TCRM.S372676","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"Pharmacology, Toxicology and Pharmaceutics","Score":null,"Total":0}
引用次数: 1

摘要

简介:不同类型的注射可以保守治疗不同的肌肉骨骼病理,在大多数情况下,如果在注射药物溶液之前先抽吸现有的炎症液,结果会明显更好。本研究分析了一种原始技术,该技术使用输液治疗附件创建两种类型的封闭无菌双注射器系统,并比较了在抽吸/注射过程中使用这种系统与传统的抽吸注射技术的好处,传统的抽吸注射技术意味着将多个注射器更换和连接到同一根针头上,从而增加了脓毒性并发症的风险。本研究的目的是尽量减少吸入/注射过程中医源性脓毒症并发症的治疗风险。方法:2015年至2020年,我院1024例患者采用双注射器系统进行吸注手术。在研究的早期阶段,第二种类型的组装是不切实际的,所以研究继续分析单一类型的双注射器系统,使用三路输注治疗装置,这是现成的,并允许组装一个封闭的无菌系统与一个单一的,两步程序技术。医源性局部脓毒性并发症通过六周的临床随访评估,必要时才进行额外的调查。结果:在1024例手术中,我们报告医源性脓毒症并发症或其他类型并发症的发生率为0%,并在大量需要吸注/注射手术的风湿病、骨科或创伤性疾病中推荐使用该技术。讨论:双注射器系统实用,易于使用,完全消除了由于操作错误导致的医源性感染的风险,并大大简化了超声引导下肌肉骨骼病理吸注操作的技术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Using a Double Syringe Sterile System for MSK Aspiration/Injection Procedures Eliminates Risk of Iatrogenic Infection.

Using a Double Syringe Sterile System for MSK Aspiration/Injection Procedures Eliminates Risk of Iatrogenic Infection.

Using a Double Syringe Sterile System for MSK Aspiration/Injection Procedures Eliminates Risk of Iatrogenic Infection.

Using a Double Syringe Sterile System for MSK Aspiration/Injection Procedures Eliminates Risk of Iatrogenic Infection.

Introduction: Diverse musculo-skeletal pathology can be treated conservatively by different types of injections and in most cases, results are significantly better if the existing inflammatory fluid is aspirated prior to injection of medication solutions. The present study analyses an original technique which uses infusion therapy accessories to create two types of closed sterile double syringe systems, and compares the benefits of using such a system in aspiration/injection procedures to classic aspiration injection technique that implies changing and connecting multiple syringes to the same needle, thus increasing the risk for septic complications. The aim of the present study is to minimize therapeutic risk of iatrogenic septic complications during aspiration/injection procedures.

Methods: 1024 patients underwent aspiration/injection procedures in our clinic using the double syringe system between 2015 and 2020. During the early stages of the study, the second type of assembly was rendered impractical so the study continued with analyzing a single type of double syringe system using a three way infusion therapy device which is readily available, and allows the assembly of a closed sterile system with a single, two-step procedure technique. Iatrogenic local septic complications were followed by means of a six week clinical follow-up evaluation with additional investigations only if necessary.

Results: In 1024 procedures we report 0% incidence of iatrogenic septic complications, or other types of complications and recommend this technique in a vast array of rheumatic, orthopedic or traumatic conditions that require aspiration/injection procedures.

Discussion: The double syringe system is practical, easy to use, it completely eliminates the risk of iatrogenic infection due to manipulation errors, and significantly simplifies the technique for sonography guided aspiration/injection procedures for musculo-skeletal pathology.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Therapeutics and Clinical Risk Management
Therapeutics and Clinical Risk Management HEALTH CARE SCIENCES & SERVICES-
CiteScore
5.30
自引率
3.60%
发文量
139
审稿时长
16 weeks
期刊介绍: Therapeutics and Clinical Risk Management is an international, peer-reviewed journal of clinical therapeutics and risk management, focusing on concise rapid reporting of clinical studies in all therapeutic areas, outcomes, safety, and programs for the effective, safe, and sustained use of medicines, therapeutic and surgical interventions in all clinical areas. The journal welcomes submissions covering original research, clinical and epidemiological studies, reviews, guidelines, expert opinion and commentary. The journal will consider case reports but only if they make a valuable and original contribution to the literature. As of 18th March 2019, Therapeutics and Clinical Risk Management will no longer consider meta-analyses for publication. The journal does not accept study protocols, animal-based or cell line-based studies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信