一例使用 Evolut PRO 进行经导管主动脉瓣置换术后因人工瓣膜心内膜炎导致升主动脉巨大假性动脉瘤和主动脉瓣置换术的患者。

IF 1.1 4区 医学 Q4 CARDIAC & CARDIOVASCULAR SYSTEMS
Satoru Tomita, Koichi Maeda, Kazuo Shimamura, Kizuku Yamashita, Ai Kawamura, Daisuke Yoshioka, Shigeru Miyagawa
{"title":"一例使用 Evolut PRO 进行经导管主动脉瓣置换术后因人工瓣膜心内膜炎导致升主动脉巨大假性动脉瘤和主动脉瓣置换术的患者。","authors":"Satoru Tomita, Koichi Maeda, Kazuo Shimamura, Kizuku Yamashita, Ai Kawamura, Daisuke Yoshioka, Shigeru Miyagawa","doi":"10.5761/atcs.cr.22-00089","DOIUrl":null,"url":null,"abstract":"<p><p>An 82-year-old man who underwent transcatheter aortic valve replacement (TAVR) using a 34-mm Evolut PRO (Medtronic, Minneapolis, MN, USA) for severe aortic stenosis 21 months previously presented with fever. Transesophageal echocardiography showed thickening of the valve leaflets of the transcatheter heart valve and movable structures such as verrucae on the upper edge of the Evolut PRO stent. Contrast-enhanced cardiac computed tomography showed a 72-mm saccular pseudoaneurysm on the dorsal aspect of the ascending aorta at the superior border of the Evolut PRO stent. Because of a suspected infected aortic aneurysm caused by prosthetic valve endocarditis (PVE), we performed aortic valve replacement using 23 mm Avalus (Medtronic, Minneapolis, MN, USA) and ascending aortic replacement using 26 mm Gelweave (Vascutek Terumo Inc, Scotland, UK). The postoperative course was uneventful. This report highlights that patients with PVE after TAVR may develop pseudoaneurysms of the ascending aorta.</p>","PeriodicalId":8037,"journal":{"name":"Annals of Thoracic and Cardiovascular Surgery","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2024-01-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10902662/pdf/","citationCount":"0","resultStr":"{\"title\":\"A Case of Ascending Aortic Replacement and Aortic Valve Replacement in a Patient with Giant Pseudoaneurysm of the Ascending Aorta due to Prosthetic Valve Endocarditis after Transcatheter Aortic Valve Replacement Using Evolut PRO.\",\"authors\":\"Satoru Tomita, Koichi Maeda, Kazuo Shimamura, Kizuku Yamashita, Ai Kawamura, Daisuke Yoshioka, Shigeru Miyagawa\",\"doi\":\"10.5761/atcs.cr.22-00089\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>An 82-year-old man who underwent transcatheter aortic valve replacement (TAVR) using a 34-mm Evolut PRO (Medtronic, Minneapolis, MN, USA) for severe aortic stenosis 21 months previously presented with fever. Transesophageal echocardiography showed thickening of the valve leaflets of the transcatheter heart valve and movable structures such as verrucae on the upper edge of the Evolut PRO stent. Contrast-enhanced cardiac computed tomography showed a 72-mm saccular pseudoaneurysm on the dorsal aspect of the ascending aorta at the superior border of the Evolut PRO stent. Because of a suspected infected aortic aneurysm caused by prosthetic valve endocarditis (PVE), we performed aortic valve replacement using 23 mm Avalus (Medtronic, Minneapolis, MN, USA) and ascending aortic replacement using 26 mm Gelweave (Vascutek Terumo Inc, Scotland, UK). The postoperative course was uneventful. This report highlights that patients with PVE after TAVR may develop pseudoaneurysms of the ascending aorta.</p>\",\"PeriodicalId\":8037,\"journal\":{\"name\":\"Annals of Thoracic and Cardiovascular Surgery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-01-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10902662/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of Thoracic and Cardiovascular Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5761/atcs.cr.22-00089\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/8/24 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Thoracic and Cardiovascular Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5761/atcs.cr.22-00089","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/8/24 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

一名82岁的男性在21个月前因主动脉瓣严重狭窄接受了经导管主动脉瓣置换术(TAVR),使用的是34毫米的Evolut PRO支架(美敦力公司,美国明尼阿波利斯)。经食管超声心动图显示,经导管心脏瓣膜的瓣叶增厚,Evolut PRO支架上缘出现疣等可移动结构。对比增强心脏计算机断层扫描显示,在Evolut PRO支架上缘的升主动脉背侧有一个72毫米的囊状假动脉瘤。由于怀疑是由人工瓣膜心内膜炎(PVE)引起的主动脉瘤感染,我们使用 23 毫米 Avalus(美敦力,美国明尼阿波利斯)进行了主动脉瓣置换术,并使用 26 毫米 Gelweave(Vascutek Terumo Inc,英国苏格兰)进行了升主动脉置换术。术后恢复顺利。本报告强调了 TAVR 术后 PVE 患者可能会出现升主动脉假性动脉瘤。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Case of Ascending Aortic Replacement and Aortic Valve Replacement in a Patient with Giant Pseudoaneurysm of the Ascending Aorta due to Prosthetic Valve Endocarditis after Transcatheter Aortic Valve Replacement Using Evolut PRO.

An 82-year-old man who underwent transcatheter aortic valve replacement (TAVR) using a 34-mm Evolut PRO (Medtronic, Minneapolis, MN, USA) for severe aortic stenosis 21 months previously presented with fever. Transesophageal echocardiography showed thickening of the valve leaflets of the transcatheter heart valve and movable structures such as verrucae on the upper edge of the Evolut PRO stent. Contrast-enhanced cardiac computed tomography showed a 72-mm saccular pseudoaneurysm on the dorsal aspect of the ascending aorta at the superior border of the Evolut PRO stent. Because of a suspected infected aortic aneurysm caused by prosthetic valve endocarditis (PVE), we performed aortic valve replacement using 23 mm Avalus (Medtronic, Minneapolis, MN, USA) and ascending aortic replacement using 26 mm Gelweave (Vascutek Terumo Inc, Scotland, UK). The postoperative course was uneventful. This report highlights that patients with PVE after TAVR may develop pseudoaneurysms of the ascending aorta.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Annals of Thoracic and Cardiovascular Surgery
Annals of Thoracic and Cardiovascular Surgery CARDIAC & CARDIOVASCULAR SYSTEMS-SURGERY
CiteScore
2.80
自引率
0.00%
发文量
56
审稿时长
4-8 weeks
期刊介绍: Information not localized
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信