Deyar Jallal Hadi Mahmood, Ewa H Linderoth, Per Vult Von Steyern, Ann Wennerberg
{"title":"不同接头设计和生产历史的全陶瓷(Y-TZP)三单元和四单元固定义齿的断裂强度。","authors":"Deyar Jallal Hadi Mahmood, Ewa H Linderoth, Per Vult Von Steyern, Ann Wennerberg","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>To investigate how different default settings for connector design of two different CAD/CAM systems, i.e. to compare how different radii of curvature in the embrasure area of the connector affect the fracture strength and the fracture mode of 3-unit and 4-unit all-ceramic FDPs made from Y-TZP and to investigate how the number of pontics affect the fracture strength of Y-TZP.</p><p><strong>Material and methods: </strong>32 all-ceramic three (3Z) and four (4Z)-unit, Y-TZP, FDP cores were made and divided in 4 groups, with 8 FDP in each group. The groups 3Z:1 and 4Z:1 were generated with a mechanical scanner, Procera Forte and the FDPs in group 3Z:2 and 4Z:2 were generated with an optical scanner, NobelProcera Scanner. The connector dimensions were set to 3 mm x 3 mm and core was set to 0.7 mm. The design of radius of the gingival and occlusal embrasures in the connector areas was set according to default settings and the manufacturer's recommendations. All the FDP cores were subjected to heat treatment, thermocycled for 5,000 cycles, preloaded for 10,000 cycles to simulate ageing and finally loaded to fracture.</p><p><strong>Results: </strong>Regarding connector design a significant difference was found between group 3Z:1 and 3Z:2 (P<0.05), and group 4Z:1 (50% of the FDPs fractured during preloading 30-300N) and 4Z:2 (P<0.05). An extra pontic decreased the fracture strength up to 45%.</p><p><strong>Conclusions: </strong>The default settings of the two different CAD/CAM systems had a great impact on the fracture strength. It is important that a CAD/CAM system is equipped with possibilities to design a connector that fulfils the clinical demands of mechanical function and longevity. The most crucial factor for the load-bearing capacity isthe design of the radius of the gingival embrasures. Increasing the number of pontics from three to four decreases the load-bearing capacity nearly twice.</p>","PeriodicalId":22114,"journal":{"name":"Swedish dental journal","volume":"37 4","pages":"179-87"},"PeriodicalIF":0.0000,"publicationDate":"2013-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fracture strength of all-ceramic (Y-TZP) three- and four-unit fixed dental prostheses with different connector design and production history.\",\"authors\":\"Deyar Jallal Hadi Mahmood, Ewa H Linderoth, Per Vult Von Steyern, Ann Wennerberg\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aims: </strong>To investigate how different default settings for connector design of two different CAD/CAM systems, i.e. to compare how different radii of curvature in the embrasure area of the connector affect the fracture strength and the fracture mode of 3-unit and 4-unit all-ceramic FDPs made from Y-TZP and to investigate how the number of pontics affect the fracture strength of Y-TZP.</p><p><strong>Material and methods: </strong>32 all-ceramic three (3Z) and four (4Z)-unit, Y-TZP, FDP cores were made and divided in 4 groups, with 8 FDP in each group. The groups 3Z:1 and 4Z:1 were generated with a mechanical scanner, Procera Forte and the FDPs in group 3Z:2 and 4Z:2 were generated with an optical scanner, NobelProcera Scanner. The connector dimensions were set to 3 mm x 3 mm and core was set to 0.7 mm. The design of radius of the gingival and occlusal embrasures in the connector areas was set according to default settings and the manufacturer's recommendations. All the FDP cores were subjected to heat treatment, thermocycled for 5,000 cycles, preloaded for 10,000 cycles to simulate ageing and finally loaded to fracture.</p><p><strong>Results: </strong>Regarding connector design a significant difference was found between group 3Z:1 and 3Z:2 (P<0.05), and group 4Z:1 (50% of the FDPs fractured during preloading 30-300N) and 4Z:2 (P<0.05). An extra pontic decreased the fracture strength up to 45%.</p><p><strong>Conclusions: </strong>The default settings of the two different CAD/CAM systems had a great impact on the fracture strength. It is important that a CAD/CAM system is equipped with possibilities to design a connector that fulfils the clinical demands of mechanical function and longevity. The most crucial factor for the load-bearing capacity isthe design of the radius of the gingival embrasures. Increasing the number of pontics from three to four decreases the load-bearing capacity nearly twice.</p>\",\"PeriodicalId\":22114,\"journal\":{\"name\":\"Swedish dental journal\",\"volume\":\"37 4\",\"pages\":\"179-87\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Swedish dental journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Swedish dental journal","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0
摘要
目的:研究两种不同CAD/CAM系统对连接器设计的不同默认设置,即比较由Y-TZP制成的3-unit和4-unit全陶瓷fdp的不同曲率半径对连接器断裂强度和断裂模式的影响,以及研究柱数对Y-TZP断裂强度的影响。材料与方法:制作全陶瓷三(3Z)和四(4Z)-单元,Y-TZP, FDP芯32个,分为4组,每组8个FDP。3Z:1和4Z:1组用机械扫描仪生成Procera Forte, 3Z:2和4Z:2组用光学扫描仪NobelProcera scanner生成fdp。连接器尺寸设置为3mm x 3mm,芯设置为0.7 mm。根据默认设置和制造商的建议设置连接区域的牙龈半径和咬合膜的设计。所有FDP芯都经过热处理,热循环5000次,预加载10000次以模拟老化,最后加载至断裂。结果:3Z:1组与3Z:2组在连接器设计上存在显著差异(p)。结论:两种不同CAD/CAM系统的默认设置对断裂强度有很大影响。重要的是,CAD/CAM系统配备了设计连接器的可能性,以满足临床对机械功能和寿命的要求。龈膜半径的设计是影响龈膜承载能力的关键因素。将桥架的数量从3个增加到4个,其承载能力降低了近两倍。
Fracture strength of all-ceramic (Y-TZP) three- and four-unit fixed dental prostheses with different connector design and production history.
Aims: To investigate how different default settings for connector design of two different CAD/CAM systems, i.e. to compare how different radii of curvature in the embrasure area of the connector affect the fracture strength and the fracture mode of 3-unit and 4-unit all-ceramic FDPs made from Y-TZP and to investigate how the number of pontics affect the fracture strength of Y-TZP.
Material and methods: 32 all-ceramic three (3Z) and four (4Z)-unit, Y-TZP, FDP cores were made and divided in 4 groups, with 8 FDP in each group. The groups 3Z:1 and 4Z:1 were generated with a mechanical scanner, Procera Forte and the FDPs in group 3Z:2 and 4Z:2 were generated with an optical scanner, NobelProcera Scanner. The connector dimensions were set to 3 mm x 3 mm and core was set to 0.7 mm. The design of radius of the gingival and occlusal embrasures in the connector areas was set according to default settings and the manufacturer's recommendations. All the FDP cores were subjected to heat treatment, thermocycled for 5,000 cycles, preloaded for 10,000 cycles to simulate ageing and finally loaded to fracture.
Results: Regarding connector design a significant difference was found between group 3Z:1 and 3Z:2 (P<0.05), and group 4Z:1 (50% of the FDPs fractured during preloading 30-300N) and 4Z:2 (P<0.05). An extra pontic decreased the fracture strength up to 45%.
Conclusions: The default settings of the two different CAD/CAM systems had a great impact on the fracture strength. It is important that a CAD/CAM system is equipped with possibilities to design a connector that fulfils the clinical demands of mechanical function and longevity. The most crucial factor for the load-bearing capacity isthe design of the radius of the gingival embrasures. Increasing the number of pontics from three to four decreases the load-bearing capacity nearly twice.
期刊介绍:
Swedish Dental Journal is the scientific journal of the Swedish Dental Association and the Swedish Dental Society. It is published 4 times a year to promote practice, education and research within odontology. Manuscripts containing original research are accepted for consideraion if neither the article nor any part of its essential substance has been or will be published elsewhere. Reviews, Case Reports and Short Communications will also be considered for publication.