自拟合助听器的阈值测量:可行性和挑战。

Trends in Amplification Pub Date : 2011-12-01 Epub Date: 2012-03-07 DOI:10.1177/1084713812438700
Gitte Keidser, Harvey Dillon, Dan Zhou, Lyndal Carter
{"title":"自拟合助听器的阈值测量:可行性和挑战。","authors":"Gitte Keidser,&nbsp;Harvey Dillon,&nbsp;Dan Zhou,&nbsp;Lyndal Carter","doi":"10.1177/1084713812438700","DOIUrl":null,"url":null,"abstract":"<p><p>A self-fitting, self-contained hearing aid is a device that can be managed entirely by the user, without assistance from a hearing health care professional or the need for special equipment. A key component of such a device is an automated audiometer that will enable the user to self-administer measurements of in situ thresholds, which the hearing aid will use to prescribe a baseline setting for the wearer. The success of the device therefore depends on the validity and reliability of in situ threshold measurements and automatically measured thresholds. To produce a complete and self-contained device, the self-fitting hearing aid will also enable identification of audiograms that are contraindicative of hearing aid usage. The feasibility and challenges of achieving these characteristics are explored and discussed. While the overall concept seems feasible, several challenges were identified that need thorough investigation and/or development. These include the use of instructions to self-manage hearing aid insertion and in situ threshold measurements, selection of an appropriate transducer and instant-fit tip that will allow measurements of a wide range of threshold levels, control of ambient noise during threshold measurements, and self-manageable procedures that enable identification of such audiogram characteristics as asymmetry and conductive hearing loss.</p>","PeriodicalId":48972,"journal":{"name":"Trends in Amplification","volume":" ","pages":"167-74"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/1084713812438700","citationCount":"14","resultStr":"{\"title\":\"Threshold measurements by self-fitting hearing aids: feasibility and challenges.\",\"authors\":\"Gitte Keidser,&nbsp;Harvey Dillon,&nbsp;Dan Zhou,&nbsp;Lyndal Carter\",\"doi\":\"10.1177/1084713812438700\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A self-fitting, self-contained hearing aid is a device that can be managed entirely by the user, without assistance from a hearing health care professional or the need for special equipment. A key component of such a device is an automated audiometer that will enable the user to self-administer measurements of in situ thresholds, which the hearing aid will use to prescribe a baseline setting for the wearer. The success of the device therefore depends on the validity and reliability of in situ threshold measurements and automatically measured thresholds. To produce a complete and self-contained device, the self-fitting hearing aid will also enable identification of audiograms that are contraindicative of hearing aid usage. The feasibility and challenges of achieving these characteristics are explored and discussed. While the overall concept seems feasible, several challenges were identified that need thorough investigation and/or development. These include the use of instructions to self-manage hearing aid insertion and in situ threshold measurements, selection of an appropriate transducer and instant-fit tip that will allow measurements of a wide range of threshold levels, control of ambient noise during threshold measurements, and self-manageable procedures that enable identification of such audiogram characteristics as asymmetry and conductive hearing loss.</p>\",\"PeriodicalId\":48972,\"journal\":{\"name\":\"Trends in Amplification\",\"volume\":\" \",\"pages\":\"167-74\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1177/1084713812438700\",\"citationCount\":\"14\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Trends in Amplification\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/1084713812438700\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2012/3/7 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Trends in Amplification","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/1084713812438700","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2012/3/7 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

摘要

自装式、自成一体的助听器是一种可以完全由使用者管理的设备,不需要听力保健专业人员的帮助,也不需要特殊设备。这种设备的一个关键部件是一个自动听力计,它将使用户能够自行管理原位阈值的测量,助听器将使用它为佩戴者规定一个基线设置。因此,该装置的成功取决于原位阈值测量和自动测量阈值的有效性和可靠性。为了生产一个完整和独立的设备,自配助听器还可以识别使用助听器的禁忌听力图。探讨了实现这些特性的可行性和挑战。虽然整体概念似乎可行,但仍存在一些需要深入调查和/或开发的挑战。这些包括使用指令来自我管理助听器插入和原位阈值测量,选择合适的换能器和即时安装的尖端,允许测量大范围的阈值水平,在阈值测量期间控制环境噪声,以及能够识别诸如不对称和传导性听力损失等听力图特征的自我管理程序。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Threshold measurements by self-fitting hearing aids: feasibility and challenges.

A self-fitting, self-contained hearing aid is a device that can be managed entirely by the user, without assistance from a hearing health care professional or the need for special equipment. A key component of such a device is an automated audiometer that will enable the user to self-administer measurements of in situ thresholds, which the hearing aid will use to prescribe a baseline setting for the wearer. The success of the device therefore depends on the validity and reliability of in situ threshold measurements and automatically measured thresholds. To produce a complete and self-contained device, the self-fitting hearing aid will also enable identification of audiograms that are contraindicative of hearing aid usage. The feasibility and challenges of achieving these characteristics are explored and discussed. While the overall concept seems feasible, several challenges were identified that need thorough investigation and/or development. These include the use of instructions to self-manage hearing aid insertion and in situ threshold measurements, selection of an appropriate transducer and instant-fit tip that will allow measurements of a wide range of threshold levels, control of ambient noise during threshold measurements, and self-manageable procedures that enable identification of such audiogram characteristics as asymmetry and conductive hearing loss.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Trends in Amplification
Trends in Amplification AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY-OTORHINOLARYNGOLOGY
自引率
0.00%
发文量
0
审稿时长
>12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信