基于FBG传感器的柔性针机器人自动标定系统的研究。

Kefan Song, Dimitri A Lezcano, Ge Sun, Jin Seob Kim, Iulian I Iordachita
{"title":"基于FBG传感器的柔性针机器人自动标定系统的研究。","authors":"Kefan Song,&nbsp;Dimitri A Lezcano,&nbsp;Ge Sun,&nbsp;Jin Seob Kim,&nbsp;Iulian I Iordachita","doi":"10.1109/ismr48346.2021.9661542","DOIUrl":null,"url":null,"abstract":"<p><p>There has been much research exploring the use of fiber Bragg grating (FBG)-sensorized needles in the prostate biopsy procedure, but all FBG needles used in the research need to be calibrated, which is time consuming and prone to human errors. In this work, a semi-automatic robotic system was developed to perform FBG needle calibration. Compared to manual calibration results, the robotic system is able to calibrate FBG needles with the similar level of accuracy as achieved by an experienced manual operator, thus reducing the time cost during the needle calibration process.</p>","PeriodicalId":72029,"journal":{"name":"... International Symposium on Medical Robotics. International Symposium on Medical Robotics","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8855976/pdf/nihms-1777037.pdf","citationCount":"4","resultStr":"{\"title\":\"Towards Automatic Robotic Calibration System for Flexible Needles with FBG Sensors.\",\"authors\":\"Kefan Song,&nbsp;Dimitri A Lezcano,&nbsp;Ge Sun,&nbsp;Jin Seob Kim,&nbsp;Iulian I Iordachita\",\"doi\":\"10.1109/ismr48346.2021.9661542\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>There has been much research exploring the use of fiber Bragg grating (FBG)-sensorized needles in the prostate biopsy procedure, but all FBG needles used in the research need to be calibrated, which is time consuming and prone to human errors. In this work, a semi-automatic robotic system was developed to perform FBG needle calibration. Compared to manual calibration results, the robotic system is able to calibrate FBG needles with the similar level of accuracy as achieved by an experienced manual operator, thus reducing the time cost during the needle calibration process.</p>\",\"PeriodicalId\":72029,\"journal\":{\"name\":\"... International Symposium on Medical Robotics. International Symposium on Medical Robotics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8855976/pdf/nihms-1777037.pdf\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"... International Symposium on Medical Robotics. International Symposium on Medical Robotics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ismr48346.2021.9661542\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"... International Symposium on Medical Robotics. International Symposium on Medical Robotics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ismr48346.2021.9661542","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

在前列腺活检过程中使用光纤布拉格光栅(FBG)传感针已经有了很多研究,但研究中使用的所有光纤光栅针都需要校准,这既耗时又容易出现人为错误。在这项工作中,开发了一个半自动机器人系统来执行光纤光栅针校准。与手动校准结果相比,机器人系统能够以与经验丰富的手动操作员相似的精度校准FBG针,从而减少针校准过程中的时间成本。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Towards Automatic Robotic Calibration System for Flexible Needles with FBG Sensors.

Towards Automatic Robotic Calibration System for Flexible Needles with FBG Sensors.

There has been much research exploring the use of fiber Bragg grating (FBG)-sensorized needles in the prostate biopsy procedure, but all FBG needles used in the research need to be calibrated, which is time consuming and prone to human errors. In this work, a semi-automatic robotic system was developed to perform FBG needle calibration. Compared to manual calibration results, the robotic system is able to calibrate FBG needles with the similar level of accuracy as achieved by an experienced manual operator, thus reducing the time cost during the needle calibration process.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信