Bao Lin Fan, Xin Ya Li, Jian Xia Wang, Shu Bin Wu, Chuan Bin Guo, Jie Fei Shen, Jin Ning Zhang, Ji Qing Yang, Xin Chen Zhao, Jian Hua Lin
{"title":"椅子旁用电动聚合活化剂的质量控制指南。","authors":"Bao Lin Fan, Xin Ya Li, Jian Xia Wang, Shu Bin Wu, Chuan Bin Guo, Jie Fei Shen, Jin Ning Zhang, Ji Qing Yang, Xin Chen Zhao, Jian Hua Lin","doi":"10.3290/j.cjdr.b2440803","DOIUrl":null,"url":null,"abstract":"<p><p>The irradiance of powered polymerisation activators for chairside use affects composite resin adhesive curing during the restorative process, whereas radiant accumulated temperature rise relates to clinical safety. Irradiance reduction and high radiant accumulated temperature will compromise the treatment results as there is a lack of curing output efficacy and safety awareness for powered polymerisation activators. Insufficient attention has been paid to the activator's quality control, irradiance attenuation and radiant accumulated temperature excessive temperature rise during its lifetime. The present manuscript has been drafted by the Society of Dental Equipment, Chinese Stomatological Association to fill the quality control gap and guide the quality control process, following tested steps, using a metered radiometer and a thermometer to record the irradiance and radiant accumulated temperature separately. The testing result may indicate the equipment's situation in service and provide information about the irradiance values and performance of the powered polymerisation activator for its usage and maintenance.</p>","PeriodicalId":74983,"journal":{"name":"The Chinese journal of dental research : the official journal of the Scientific Section of the Chinese Stomatological Association (CSA)","volume":"24 4","pages":"231-234"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Guideline for Quality Control of Powered Polymerisation Activators for Chairside Use.\",\"authors\":\"Bao Lin Fan, Xin Ya Li, Jian Xia Wang, Shu Bin Wu, Chuan Bin Guo, Jie Fei Shen, Jin Ning Zhang, Ji Qing Yang, Xin Chen Zhao, Jian Hua Lin\",\"doi\":\"10.3290/j.cjdr.b2440803\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The irradiance of powered polymerisation activators for chairside use affects composite resin adhesive curing during the restorative process, whereas radiant accumulated temperature rise relates to clinical safety. Irradiance reduction and high radiant accumulated temperature will compromise the treatment results as there is a lack of curing output efficacy and safety awareness for powered polymerisation activators. Insufficient attention has been paid to the activator's quality control, irradiance attenuation and radiant accumulated temperature excessive temperature rise during its lifetime. The present manuscript has been drafted by the Society of Dental Equipment, Chinese Stomatological Association to fill the quality control gap and guide the quality control process, following tested steps, using a metered radiometer and a thermometer to record the irradiance and radiant accumulated temperature separately. The testing result may indicate the equipment's situation in service and provide information about the irradiance values and performance of the powered polymerisation activator for its usage and maintenance.</p>\",\"PeriodicalId\":74983,\"journal\":{\"name\":\"The Chinese journal of dental research : the official journal of the Scientific Section of the Chinese Stomatological Association (CSA)\",\"volume\":\"24 4\",\"pages\":\"231-234\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Chinese journal of dental research : the official journal of the Scientific Section of the Chinese Stomatological Association (CSA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3290/j.cjdr.b2440803\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Chinese journal of dental research : the official journal of the Scientific Section of the Chinese Stomatological Association (CSA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3290/j.cjdr.b2440803","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Guideline for Quality Control of Powered Polymerisation Activators for Chairside Use.
The irradiance of powered polymerisation activators for chairside use affects composite resin adhesive curing during the restorative process, whereas radiant accumulated temperature rise relates to clinical safety. Irradiance reduction and high radiant accumulated temperature will compromise the treatment results as there is a lack of curing output efficacy and safety awareness for powered polymerisation activators. Insufficient attention has been paid to the activator's quality control, irradiance attenuation and radiant accumulated temperature excessive temperature rise during its lifetime. The present manuscript has been drafted by the Society of Dental Equipment, Chinese Stomatological Association to fill the quality control gap and guide the quality control process, following tested steps, using a metered radiometer and a thermometer to record the irradiance and radiant accumulated temperature separately. The testing result may indicate the equipment's situation in service and provide information about the irradiance values and performance of the powered polymerisation activator for its usage and maintenance.