椅子旁用电动聚合活化剂的质量控制指南。

Bao Lin Fan, Xin Ya Li, Jian Xia Wang, Shu Bin Wu, Chuan Bin Guo, Jie Fei Shen, Jin Ning Zhang, Ji Qing Yang, Xin Chen Zhao, Jian Hua Lin
{"title":"椅子旁用电动聚合活化剂的质量控制指南。","authors":"Bao Lin Fan,&nbsp;Xin Ya Li,&nbsp;Jian Xia Wang,&nbsp;Shu Bin Wu,&nbsp;Chuan Bin Guo,&nbsp;Jie Fei Shen,&nbsp;Jin Ning Zhang,&nbsp;Ji Qing Yang,&nbsp;Xin Chen Zhao,&nbsp;Jian Hua Lin","doi":"10.3290/j.cjdr.b2440803","DOIUrl":null,"url":null,"abstract":"<p><p>The irradiance of powered polymerisation activators for chairside use affects composite resin adhesive curing during the restorative process, whereas radiant accumulated temperature rise relates to clinical safety. Irradiance reduction and high radiant accumulated temperature will compromise the treatment results as there is a lack of curing output efficacy and safety awareness for powered polymerisation activators. Insufficient attention has been paid to the activator's quality control, irradiance attenuation and radiant accumulated temperature excessive temperature rise during its lifetime. The present manuscript has been drafted by the Society of Dental Equipment, Chinese Stomatological Association to fill the quality control gap and guide the quality control process, following tested steps, using a metered radiometer and a thermometer to record the irradiance and radiant accumulated temperature separately. The testing result may indicate the equipment's situation in service and provide information about the irradiance values and performance of the powered polymerisation activator for its usage and maintenance.</p>","PeriodicalId":74983,"journal":{"name":"The Chinese journal of dental research : the official journal of the Scientific Section of the Chinese Stomatological Association (CSA)","volume":"24 4","pages":"231-234"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Guideline for Quality Control of Powered Polymerisation Activators for Chairside Use.\",\"authors\":\"Bao Lin Fan,&nbsp;Xin Ya Li,&nbsp;Jian Xia Wang,&nbsp;Shu Bin Wu,&nbsp;Chuan Bin Guo,&nbsp;Jie Fei Shen,&nbsp;Jin Ning Zhang,&nbsp;Ji Qing Yang,&nbsp;Xin Chen Zhao,&nbsp;Jian Hua Lin\",\"doi\":\"10.3290/j.cjdr.b2440803\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The irradiance of powered polymerisation activators for chairside use affects composite resin adhesive curing during the restorative process, whereas radiant accumulated temperature rise relates to clinical safety. Irradiance reduction and high radiant accumulated temperature will compromise the treatment results as there is a lack of curing output efficacy and safety awareness for powered polymerisation activators. Insufficient attention has been paid to the activator's quality control, irradiance attenuation and radiant accumulated temperature excessive temperature rise during its lifetime. The present manuscript has been drafted by the Society of Dental Equipment, Chinese Stomatological Association to fill the quality control gap and guide the quality control process, following tested steps, using a metered radiometer and a thermometer to record the irradiance and radiant accumulated temperature separately. The testing result may indicate the equipment's situation in service and provide information about the irradiance values and performance of the powered polymerisation activator for its usage and maintenance.</p>\",\"PeriodicalId\":74983,\"journal\":{\"name\":\"The Chinese journal of dental research : the official journal of the Scientific Section of the Chinese Stomatological Association (CSA)\",\"volume\":\"24 4\",\"pages\":\"231-234\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Chinese journal of dental research : the official journal of the Scientific Section of the Chinese Stomatological Association (CSA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3290/j.cjdr.b2440803\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Chinese journal of dental research : the official journal of the Scientific Section of the Chinese Stomatological Association (CSA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3290/j.cjdr.b2440803","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

椅子旁使用的动力聚合活化剂的辐照度影响复合树脂胶粘剂在修复过程中的固化,而辐射累积温升关系到临床安全性。辐照度降低和高辐射积温将影响处理结果,因为缺乏of固化输出效率和对动力聚合活化剂的安全意识。活化剂在使用寿命期间的质量控制、辐照衰减和辐射积温过高温升等问题没有得到足够的重视。为了填补质量控制空白,指导质量控制过程,本文由中国口腔学会口腔器械专业Society起草,采用计量辐射计和温度计分别记录辐照度和辐射积温。测试结果可以指示设备的使用情况,并为其使用和维护提供有关动力聚合活化剂的辐照度值和性能的信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Guideline for Quality Control of Powered Polymerisation Activators for Chairside Use.

The irradiance of powered polymerisation activators for chairside use affects composite resin adhesive curing during the restorative process, whereas radiant accumulated temperature rise relates to clinical safety. Irradiance reduction and high radiant accumulated temperature will compromise the treatment results as there is a lack of curing output efficacy and safety awareness for powered polymerisation activators. Insufficient attention has been paid to the activator's quality control, irradiance attenuation and radiant accumulated temperature excessive temperature rise during its lifetime. The present manuscript has been drafted by the Society of Dental Equipment, Chinese Stomatological Association to fill the quality control gap and guide the quality control process, following tested steps, using a metered radiometer and a thermometer to record the irradiance and radiant accumulated temperature separately. The testing result may indicate the equipment's situation in service and provide information about the irradiance values and performance of the powered polymerisation activator for its usage and maintenance.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信