激光照明喉部高速视频内窥镜:初步报告。

IF 1 Q3 OTORHINOLARYNGOLOGY
Jakub Malinowski, Ewa Niebudek-Bogusz, Marcin Just, Joanna Morawska, Anna Racino, Joanna Hoffman, Magda Barańska, Magdalena Marianna Kowalczyk, Wioletta Pietruszewska
{"title":"激光照明喉部高速视频内窥镜:初步报告。","authors":"Jakub Malinowski,&nbsp;Ewa Niebudek-Bogusz,&nbsp;Marcin Just,&nbsp;Joanna Morawska,&nbsp;Anna Racino,&nbsp;Joanna Hoffman,&nbsp;Magda Barańska,&nbsp;Magdalena Marianna Kowalczyk,&nbsp;Wioletta Pietruszewska","doi":"10.5604/01.3001.0015.2575","DOIUrl":null,"url":null,"abstract":"<p><p>&lt;br&gt;&lt;b&gt;Introduction:&lt;/b&gt; Advances in computer image analysis have enabled the use of new functional imaging methods in the diagnosis of laryngeal diseases. Particularly interesting techniques of dynamic laryngeal imaging involve High Speed Videoendoscopy (HSV). This still-developed technique allows to overcome the limitations of laryngovideostroboscopy (LVS) and a more detailed analysis of the glottal function based on the image of the actual vibrations of the vocal folds. It also enables the determination of objective coefficients parameterizing phonatory vibrations of the vocal folds.&lt;/br&gt; &lt;br&gt;&lt;b&gt;Aim:&lt;/b&gt; The aim of this pilot study was to evaluate the use of a high-speed videoendoscopy set with laser illumination for the diagnosis of glottic pathology in ENT practice.&lt;/br&gt; &lt;br&gt;&lt;b&gt;Material and methods:&lt;/b&gt; The study included 40 patients who underwent LVS followed by HSV. The modern HSV examination kit - Advanced Larynx Imager System (ALIS), used for the first time in a clinical setting in Poland, is characterized by significantly improved, compared to the previously used high-speed cameras, operational parameters - a light head, the possibility of continuous lighting operation without excessive heating of the head tip, registration of the image in full color scale. Thanks to such modernization, the safety and course of the examination do not differ from laryngoscopy conducted with commonly used recorders. The device owes some of these improvements to a laser illuminator which was used for the first time as the main light source in a high-speed camera. In the study, two cases were selected to present the results of HSV and the analysis of the generated kymograms - a woman with no glottic pathology and a man with a polyp of the right vocal fold. In the first case, the HSV examination compared with the LVS revealed a discrete glottis functional disorder in the form of a tendency to hyperphonation. The patient with an organic lesion had a clearly visible irregularity of vocal fold vibrations, which also allowed to trace mucosal wave disturbances related to its reflection from the pathological structure of the glottis and the formation of a return wave, both on the fold affected by the lesion and, to a lesser extent, contralaterally. The glottic dysfunctions observed in the studied patients were confirmed in the generated kymograms and the graphs of the glottal width waveform (GWW), as well as in the parameters calculated on their basis, assessing the frequency and amplitude of phonatory vibrations.&lt;/br&gt; &lt;br&gt;&lt;b&gt;Conclusions:&lt;/b&gt; The use of high-speed videoendoscopy allows for a much more accurate assessment of the phonatory function of the glottis than in laryngovideostroboscopy. The presented HSV system allows for obtaining high quality kinematic images of the larynx, color fidelity, and contrast. The use of this technology in laryngological practice enables precise structural and functional assessment of the glottis and detection of discrete phonation disorders that elude the techniques used so far.&lt;/br&gt.</p>","PeriodicalId":42608,"journal":{"name":"Polish Journal of Otolaryngology","volume":"75 6","pages":"1-10"},"PeriodicalIF":1.0000,"publicationDate":"2021-09-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Laryngeal High-Speed Videoendoscopy with Laser Illumination: A Preliminary Report.\",\"authors\":\"Jakub Malinowski,&nbsp;Ewa Niebudek-Bogusz,&nbsp;Marcin Just,&nbsp;Joanna Morawska,&nbsp;Anna Racino,&nbsp;Joanna Hoffman,&nbsp;Magda Barańska,&nbsp;Magdalena Marianna Kowalczyk,&nbsp;Wioletta Pietruszewska\",\"doi\":\"10.5604/01.3001.0015.2575\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>&lt;br&gt;&lt;b&gt;Introduction:&lt;/b&gt; Advances in computer image analysis have enabled the use of new functional imaging methods in the diagnosis of laryngeal diseases. Particularly interesting techniques of dynamic laryngeal imaging involve High Speed Videoendoscopy (HSV). This still-developed technique allows to overcome the limitations of laryngovideostroboscopy (LVS) and a more detailed analysis of the glottal function based on the image of the actual vibrations of the vocal folds. It also enables the determination of objective coefficients parameterizing phonatory vibrations of the vocal folds.&lt;/br&gt; &lt;br&gt;&lt;b&gt;Aim:&lt;/b&gt; The aim of this pilot study was to evaluate the use of a high-speed videoendoscopy set with laser illumination for the diagnosis of glottic pathology in ENT practice.&lt;/br&gt; &lt;br&gt;&lt;b&gt;Material and methods:&lt;/b&gt; The study included 40 patients who underwent LVS followed by HSV. The modern HSV examination kit - Advanced Larynx Imager System (ALIS), used for the first time in a clinical setting in Poland, is characterized by significantly improved, compared to the previously used high-speed cameras, operational parameters - a light head, the possibility of continuous lighting operation without excessive heating of the head tip, registration of the image in full color scale. Thanks to such modernization, the safety and course of the examination do not differ from laryngoscopy conducted with commonly used recorders. The device owes some of these improvements to a laser illuminator which was used for the first time as the main light source in a high-speed camera. In the study, two cases were selected to present the results of HSV and the analysis of the generated kymograms - a woman with no glottic pathology and a man with a polyp of the right vocal fold. In the first case, the HSV examination compared with the LVS revealed a discrete glottis functional disorder in the form of a tendency to hyperphonation. The patient with an organic lesion had a clearly visible irregularity of vocal fold vibrations, which also allowed to trace mucosal wave disturbances related to its reflection from the pathological structure of the glottis and the formation of a return wave, both on the fold affected by the lesion and, to a lesser extent, contralaterally. The glottic dysfunctions observed in the studied patients were confirmed in the generated kymograms and the graphs of the glottal width waveform (GWW), as well as in the parameters calculated on their basis, assessing the frequency and amplitude of phonatory vibrations.&lt;/br&gt; &lt;br&gt;&lt;b&gt;Conclusions:&lt;/b&gt; The use of high-speed videoendoscopy allows for a much more accurate assessment of the phonatory function of the glottis than in laryngovideostroboscopy. The presented HSV system allows for obtaining high quality kinematic images of the larynx, color fidelity, and contrast. The use of this technology in laryngological practice enables precise structural and functional assessment of the glottis and detection of discrete phonation disorders that elude the techniques used so far.&lt;/br&gt.</p>\",\"PeriodicalId\":42608,\"journal\":{\"name\":\"Polish Journal of Otolaryngology\",\"volume\":\"75 6\",\"pages\":\"1-10\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2021-09-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Polish Journal of Otolaryngology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5604/01.3001.0015.2575\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"OTORHINOLARYNGOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Polish Journal of Otolaryngology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5604/01.3001.0015.2575","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 5

摘要

& lt; br> & lt; b>简介:& lt; / b>计算机图像分析的进步使得在喉部疾病的诊断中使用新的功能成像方法成为可能。特别有趣的动态喉部成像技术包括高速视频内窥镜(HSV)。这项仍在发展中的技术可以克服喉视频频闪检查(LVS)的局限性,并根据声带实际振动的图像对声门功能进行更详细的分析。它还可以确定客观系数,参数化声带的发声振动。</br>& lt; br> & lt; b>目的:& lt; / b>本初步研究的目的是评估激光照明高速视频内窥镜在耳鼻喉科实践中诊断声门病理的应用。<br>< & b>该研究包括40名接受LVS和HSV的患者。现代HSV检查套件-先进喉成像仪系统(ALIS),首次在波兰的临床环境中使用,与以前使用的高速相机相比,其特点是显着改进,操作参数-一个灯头,连续照明操作的可能性,而不会过度加热头部尖端,全彩色图像配位。由于这种现代化,检查的安全性和过程与使用常用记录仪进行的喉镜检查没有什么不同。该设备的一些改进要归功于激光照明器,它首次被用作高速相机的主要光源。在这项研究中,选择了两个病例来展示HSV的结果和生成的心电图分析-一个没有声门病理的女性和一个右声带息肉的男性。在第一个病例中,与LVS相比,HSV检查显示了以过度发音倾向的形式出现的离散声门功能障碍。器质性病变的患者声带振动明显不规则,这也可以追踪粘膜波的干扰,这些干扰与声门病理结构的反射有关,并且在受病变影响的褶皱上形成回波,在较小程度上,对侧也是如此。通过生成的声门图和声门宽度波形(GWW)图,以及在此基础上计算的参数,评估发声振动的频率和幅度,证实了所研究患者所观察到的声门功能障碍。& lt; br> & lt; b>结论:& lt; / b>使用高速视频内窥镜可以比喉频闪视频内窥镜更准确地评估声门的发音功能。提出的HSV系统允许获得高质量的喉运动图像,色彩保真度和对比度。在喉科实践中使用该技术可以对声门进行精确的结构和功能评估,并检测到目前为止使用的技术无法实现的离散发音障碍。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Laryngeal High-Speed Videoendoscopy with Laser Illumination: A Preliminary Report.

<br><b>Introduction:</b> Advances in computer image analysis have enabled the use of new functional imaging methods in the diagnosis of laryngeal diseases. Particularly interesting techniques of dynamic laryngeal imaging involve High Speed Videoendoscopy (HSV). This still-developed technique allows to overcome the limitations of laryngovideostroboscopy (LVS) and a more detailed analysis of the glottal function based on the image of the actual vibrations of the vocal folds. It also enables the determination of objective coefficients parameterizing phonatory vibrations of the vocal folds.</br> <br><b>Aim:</b> The aim of this pilot study was to evaluate the use of a high-speed videoendoscopy set with laser illumination for the diagnosis of glottic pathology in ENT practice.</br> <br><b>Material and methods:</b> The study included 40 patients who underwent LVS followed by HSV. The modern HSV examination kit - Advanced Larynx Imager System (ALIS), used for the first time in a clinical setting in Poland, is characterized by significantly improved, compared to the previously used high-speed cameras, operational parameters - a light head, the possibility of continuous lighting operation without excessive heating of the head tip, registration of the image in full color scale. Thanks to such modernization, the safety and course of the examination do not differ from laryngoscopy conducted with commonly used recorders. The device owes some of these improvements to a laser illuminator which was used for the first time as the main light source in a high-speed camera. In the study, two cases were selected to present the results of HSV and the analysis of the generated kymograms - a woman with no glottic pathology and a man with a polyp of the right vocal fold. In the first case, the HSV examination compared with the LVS revealed a discrete glottis functional disorder in the form of a tendency to hyperphonation. The patient with an organic lesion had a clearly visible irregularity of vocal fold vibrations, which also allowed to trace mucosal wave disturbances related to its reflection from the pathological structure of the glottis and the formation of a return wave, both on the fold affected by the lesion and, to a lesser extent, contralaterally. The glottic dysfunctions observed in the studied patients were confirmed in the generated kymograms and the graphs of the glottal width waveform (GWW), as well as in the parameters calculated on their basis, assessing the frequency and amplitude of phonatory vibrations.</br> <br><b>Conclusions:</b> The use of high-speed videoendoscopy allows for a much more accurate assessment of the phonatory function of the glottis than in laryngovideostroboscopy. The presented HSV system allows for obtaining high quality kinematic images of the larynx, color fidelity, and contrast. The use of this technology in laryngological practice enables precise structural and functional assessment of the glottis and detection of discrete phonation disorders that elude the techniques used so far.</br>.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Polish Journal of Otolaryngology
Polish Journal of Otolaryngology OTORHINOLARYNGOLOGY-
CiteScore
1.30
自引率
16.70%
发文量
15
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信