新型自动血栓造影术测量达比加群、利伐沙班和阿哌沙班治疗患者的抗凝作用。

TH Open: Companion Journal to Thrombosis and Haemostasis Pub Date : 2021-11-09 eCollection Date: 2021-10-01 DOI:10.1055/a-1692-1415
Ramin Artang, Joao D Dias, Mark Walsh, Kevin Bliden, Jorn D Nielsen, Maren Anderson, Brian C Thurston, Udaya S Tantry, Jan Hartmann, Paul A Gurbel
{"title":"新型自动血栓造影术测量达比加群、利伐沙班和阿哌沙班治疗患者的抗凝作用。","authors":"Ramin Artang,&nbsp;Joao D Dias,&nbsp;Mark Walsh,&nbsp;Kevin Bliden,&nbsp;Jorn D Nielsen,&nbsp;Maren Anderson,&nbsp;Brian C Thurston,&nbsp;Udaya S Tantry,&nbsp;Jan Hartmann,&nbsp;Paul A Gurbel","doi":"10.1055/a-1692-1415","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background</b>  Direct-acting oral anticoagulants (DOACs) do not require monitoring. Measurement of DOAC effect would be useful in the event of bleeding, trauma, and thromboembolism while on anticoagulation. We evaluated the effectiveness of the investigational DOAC assays on the TEG®6s Hemostasis Analyzer to assess the anticoagulant effect of DOACs in patients treated for atrial fibrillation or deep vein thrombosis (DVT). <b>Methods</b>  Patients on treatment for a minimum of 7 days with standard doses of dabigatran, rivaroxaban, and apixaban were included. DOAC plasma concentrations and TEG®6s Reaction (R)-time were measured and correlated. The sensitivity, specificity, and negative predictive value (NPV) of R-time to detect DOAC concentrations of ≥30, ≥50, and ≥100 ng/mL were calculated. <b>Results</b>  A total of 189 patients were included, ( <i>n</i>  = 50) on apixaban, ( <i>n</i>  = 62) on rivaroxaban, ( <i>n</i>  = 53) on dabigatran, and ( <i>n</i>  = 24) on no DOAC were studied. Using the direct thrombin inhibitor (DTI) channel, R-time demonstrated strong linear correlation with dabigatran levels (r = 0.93, <i>p</i>  < 0.0001). Using the antifactor Xa (AFXa) channel, R-time demonstrated strong nonlinear correlation with rivaroxaban and apixaban levels ( <i>r</i> <sub>s</sub>  = 0.92 and 0.84, respectively, <i>p</i>  < 0.0001 for both). R-time revealed strong sensitivity and NPV in detecting low DOAC levels for the predefined concentrations. <b>Conclusion</b>  R-time measured by TEG®6s DOAC-specific cartridge has a strong correlation with concentrations of the most commonly used DOACs with high sensitivity and NPV for detecting lower drug levels that are considered clinically relevant for patients in need of antidote, or prior to urgent surgery. Further studies to determine the relation of R-time to clinical outcomes are warranted.</p>","PeriodicalId":22238,"journal":{"name":"TH Open: Companion Journal to Thrombosis and Haemostasis","volume":"5 4","pages":"e570-e576"},"PeriodicalIF":0.0000,"publicationDate":"2021-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8718262/pdf/","citationCount":"5","resultStr":"{\"title\":\"Measurement of Anticoagulation in Patients on Dabigatran, Rivaroxaban, and Apixaban Therapy by Novel Automated Thrombelastography.\",\"authors\":\"Ramin Artang,&nbsp;Joao D Dias,&nbsp;Mark Walsh,&nbsp;Kevin Bliden,&nbsp;Jorn D Nielsen,&nbsp;Maren Anderson,&nbsp;Brian C Thurston,&nbsp;Udaya S Tantry,&nbsp;Jan Hartmann,&nbsp;Paul A Gurbel\",\"doi\":\"10.1055/a-1692-1415\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Background</b>  Direct-acting oral anticoagulants (DOACs) do not require monitoring. Measurement of DOAC effect would be useful in the event of bleeding, trauma, and thromboembolism while on anticoagulation. We evaluated the effectiveness of the investigational DOAC assays on the TEG®6s Hemostasis Analyzer to assess the anticoagulant effect of DOACs in patients treated for atrial fibrillation or deep vein thrombosis (DVT). <b>Methods</b>  Patients on treatment for a minimum of 7 days with standard doses of dabigatran, rivaroxaban, and apixaban were included. DOAC plasma concentrations and TEG®6s Reaction (R)-time were measured and correlated. The sensitivity, specificity, and negative predictive value (NPV) of R-time to detect DOAC concentrations of ≥30, ≥50, and ≥100 ng/mL were calculated. <b>Results</b>  A total of 189 patients were included, ( <i>n</i>  = 50) on apixaban, ( <i>n</i>  = 62) on rivaroxaban, ( <i>n</i>  = 53) on dabigatran, and ( <i>n</i>  = 24) on no DOAC were studied. Using the direct thrombin inhibitor (DTI) channel, R-time demonstrated strong linear correlation with dabigatran levels (r = 0.93, <i>p</i>  < 0.0001). Using the antifactor Xa (AFXa) channel, R-time demonstrated strong nonlinear correlation with rivaroxaban and apixaban levels ( <i>r</i> <sub>s</sub>  = 0.92 and 0.84, respectively, <i>p</i>  < 0.0001 for both). R-time revealed strong sensitivity and NPV in detecting low DOAC levels for the predefined concentrations. <b>Conclusion</b>  R-time measured by TEG®6s DOAC-specific cartridge has a strong correlation with concentrations of the most commonly used DOACs with high sensitivity and NPV for detecting lower drug levels that are considered clinically relevant for patients in need of antidote, or prior to urgent surgery. Further studies to determine the relation of R-time to clinical outcomes are warranted.</p>\",\"PeriodicalId\":22238,\"journal\":{\"name\":\"TH Open: Companion Journal to Thrombosis and Haemostasis\",\"volume\":\"5 4\",\"pages\":\"e570-e576\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-11-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8718262/pdf/\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"TH Open: Companion Journal to Thrombosis and Haemostasis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1055/a-1692-1415\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2021/10/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"TH Open: Companion Journal to Thrombosis and Haemostasis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/a-1692-1415","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/10/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

直接作用口服抗凝剂(DOACs)不需要监测。在抗凝治疗中发生出血、创伤和血栓栓塞的情况下,测量DOAC效应是有用的。我们在TEG®6s止血分析仪上评估DOAC的有效性,以评估DOAC在房颤或深静脉血栓(DVT)患者中的抗凝作用。方法采用标准剂量达比加群、利伐沙班和阿哌沙班治疗至少7天的患者。测定DOAC血浆浓度与TEG®6s反应(R)时间的相关性。计算R-time检测DOAC浓度≥30、≥50和≥100 ng/mL的敏感性、特异性和阴性预测值(NPV)。结果共纳入189例患者,阿哌沙班组(n = 50),利伐沙班组(n = 62),达比加群组(n = 53),无DOAC组(n = 24)。使用直接凝血酶抑制剂(DTI)通道,r -time与达比加群水平呈较强的线性相关(r = 0.93, p = 0.92, p = 0.84)。结论TEG®6s doac特异性药盒测量的r -time与最常用的DOACs浓度有很强的相关性,具有高灵敏度和NPV,可用于检测需要解毒剂或紧急手术前患者的较低药物水平。进一步研究确定R-time与临床结果的关系是必要的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Measurement of Anticoagulation in Patients on Dabigatran, Rivaroxaban, and Apixaban Therapy by Novel Automated Thrombelastography.

Measurement of Anticoagulation in Patients on Dabigatran, Rivaroxaban, and Apixaban Therapy by Novel Automated Thrombelastography.

Background  Direct-acting oral anticoagulants (DOACs) do not require monitoring. Measurement of DOAC effect would be useful in the event of bleeding, trauma, and thromboembolism while on anticoagulation. We evaluated the effectiveness of the investigational DOAC assays on the TEG®6s Hemostasis Analyzer to assess the anticoagulant effect of DOACs in patients treated for atrial fibrillation or deep vein thrombosis (DVT). Methods  Patients on treatment for a minimum of 7 days with standard doses of dabigatran, rivaroxaban, and apixaban were included. DOAC plasma concentrations and TEG®6s Reaction (R)-time were measured and correlated. The sensitivity, specificity, and negative predictive value (NPV) of R-time to detect DOAC concentrations of ≥30, ≥50, and ≥100 ng/mL were calculated. Results  A total of 189 patients were included, ( n  = 50) on apixaban, ( n  = 62) on rivaroxaban, ( n  = 53) on dabigatran, and ( n  = 24) on no DOAC were studied. Using the direct thrombin inhibitor (DTI) channel, R-time demonstrated strong linear correlation with dabigatran levels (r = 0.93, p  < 0.0001). Using the antifactor Xa (AFXa) channel, R-time demonstrated strong nonlinear correlation with rivaroxaban and apixaban levels ( r s  = 0.92 and 0.84, respectively, p  < 0.0001 for both). R-time revealed strong sensitivity and NPV in detecting low DOAC levels for the predefined concentrations. Conclusion  R-time measured by TEG®6s DOAC-specific cartridge has a strong correlation with concentrations of the most commonly used DOACs with high sensitivity and NPV for detecting lower drug levels that are considered clinically relevant for patients in need of antidote, or prior to urgent surgery. Further studies to determine the relation of R-time to clinical outcomes are warranted.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信