Alexander J Volkmar, Robert Elrod, Justin W Vickery, Charlie C Yang, Gregory G Polkowski, J Ryan Martin
{"title":"初级全膝关节置换术中的关键替代植入物。","authors":"Alexander J Volkmar, Robert Elrod, Justin W Vickery, Charlie C Yang, Gregory G Polkowski, J Ryan Martin","doi":"10.1155/2022/2676715","DOIUrl":null,"url":null,"abstract":"<p><p>The use of cruciate substituting (CS) total knee replacement has been increasing in popularity. There are numerous factors that have likely contributed to this expansion. The CS philosophy incorporates the ease of use commonly cited by advocates of the posterior stabilized (PS) total knee design with the bone preservation associated with a cruciate retaining (CR) design. The ultra-congruent highly cross-linked polyethylene liner increases stability without an appreciable change in wear. Furthermore, balancing the flexion and extension gaps does not require \"titrating\" the posterior cruciate ligament, improving the user-friendliness. This paper reviews the nuances of this implant design compared to PS and CR designs as well as provides surgical technique recommendations/considerations.</p>","PeriodicalId":7358,"journal":{"name":"Advances in Orthopedics","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2022-01-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8803465/pdf/","citationCount":"2","resultStr":"{\"title\":\"Cruciate Substituting Implants in Primary Total Knee Arthroplasty.\",\"authors\":\"Alexander J Volkmar, Robert Elrod, Justin W Vickery, Charlie C Yang, Gregory G Polkowski, J Ryan Martin\",\"doi\":\"10.1155/2022/2676715\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The use of cruciate substituting (CS) total knee replacement has been increasing in popularity. There are numerous factors that have likely contributed to this expansion. The CS philosophy incorporates the ease of use commonly cited by advocates of the posterior stabilized (PS) total knee design with the bone preservation associated with a cruciate retaining (CR) design. The ultra-congruent highly cross-linked polyethylene liner increases stability without an appreciable change in wear. Furthermore, balancing the flexion and extension gaps does not require \\\"titrating\\\" the posterior cruciate ligament, improving the user-friendliness. This paper reviews the nuances of this implant design compared to PS and CR designs as well as provides surgical technique recommendations/considerations.</p>\",\"PeriodicalId\":7358,\"journal\":{\"name\":\"Advances in Orthopedics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2022-01-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8803465/pdf/\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advances in Orthopedics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2022/2676715\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Orthopedics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2022/2676715","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Cruciate Substituting Implants in Primary Total Knee Arthroplasty.
The use of cruciate substituting (CS) total knee replacement has been increasing in popularity. There are numerous factors that have likely contributed to this expansion. The CS philosophy incorporates the ease of use commonly cited by advocates of the posterior stabilized (PS) total knee design with the bone preservation associated with a cruciate retaining (CR) design. The ultra-congruent highly cross-linked polyethylene liner increases stability without an appreciable change in wear. Furthermore, balancing the flexion and extension gaps does not require "titrating" the posterior cruciate ligament, improving the user-friendliness. This paper reviews the nuances of this implant design compared to PS and CR designs as well as provides surgical technique recommendations/considerations.
期刊介绍:
Advances in Orthopedics is a peer-reviewed, Open Access journal that provides a forum for orthopaedics working on improving the quality of orthopedic health care. The journal publishes original research articles, review articles, and clinical studies related to arthroplasty, hand surgery, limb reconstruction, pediatric orthopaedics, sports medicine, trauma, spinal deformities, and orthopaedic oncology.