Steven M Falowski, Sebastian F Koga, Trent Northcutt, Laszlo Garamszegi, Jeremi Leasure, Jon E Block
{"title":"改善骨质疏松患者脊柱融合术的管理:需要骨密度匹配的椎间笼。","authors":"Steven M Falowski, Sebastian F Koga, Trent Northcutt, Laszlo Garamszegi, Jeremi Leasure, Jon E Block","doi":"10.2147/ORR.S339222","DOIUrl":null,"url":null,"abstract":"<p><p>With an increasingly aging population globally, a confluence has emerged between the rising prevalence of degenerative spinal disease and osteoporosis. Fusion of the anterior spinal column remains the mainstay surgical intervention for many spinal degenerative disorders. However, decreased vertebral bone mineral density (BMD), quantitatively measured by dual x-ray absorptiometry (DXA), complicates treatment with surgical interbody fusion as weak underlying bone stock increases the risk of post-operative implant-related adverse events, including cage subsidence. There is a necessity for developing cages with advanced structural designs that incorporate bioengineering and architectural principles to tailor the interbody fusion device directly to the patient's BMD status. Specifically, lattice-designed cages that mimic the web-like structure of native cancellous bone have demonstrated excellent resistance to post-operative subsidence. This article provides an introductory profile of a spinal interbody implant designed intentionally to simulate the lattice structure of human cancellous bone, with a similar modulus of elasticity, and specialized to match a patient's bone status across the BMD continuum. The implant incorporates an open pore design where the degree of pore compactness directly corresponds to the patient's DXA-defined BMD status, including patients with osteoporosis.</p>","PeriodicalId":19608,"journal":{"name":"Orthopedic Research and Reviews","volume":"13 ","pages":"281-288"},"PeriodicalIF":1.7000,"publicationDate":"2021-12-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/7d/f1/orr-13-281.PMC8684416.pdf","citationCount":"1","resultStr":"{\"title\":\"Improving the Management of Patients with Osteoporosis Undergoing Spinal Fusion: The Need for a Bone Mineral Density-Matched Interbody Cage.\",\"authors\":\"Steven M Falowski, Sebastian F Koga, Trent Northcutt, Laszlo Garamszegi, Jeremi Leasure, Jon E Block\",\"doi\":\"10.2147/ORR.S339222\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>With an increasingly aging population globally, a confluence has emerged between the rising prevalence of degenerative spinal disease and osteoporosis. Fusion of the anterior spinal column remains the mainstay surgical intervention for many spinal degenerative disorders. However, decreased vertebral bone mineral density (BMD), quantitatively measured by dual x-ray absorptiometry (DXA), complicates treatment with surgical interbody fusion as weak underlying bone stock increases the risk of post-operative implant-related adverse events, including cage subsidence. There is a necessity for developing cages with advanced structural designs that incorporate bioengineering and architectural principles to tailor the interbody fusion device directly to the patient's BMD status. Specifically, lattice-designed cages that mimic the web-like structure of native cancellous bone have demonstrated excellent resistance to post-operative subsidence. This article provides an introductory profile of a spinal interbody implant designed intentionally to simulate the lattice structure of human cancellous bone, with a similar modulus of elasticity, and specialized to match a patient's bone status across the BMD continuum. The implant incorporates an open pore design where the degree of pore compactness directly corresponds to the patient's DXA-defined BMD status, including patients with osteoporosis.</p>\",\"PeriodicalId\":19608,\"journal\":{\"name\":\"Orthopedic Research and Reviews\",\"volume\":\"13 \",\"pages\":\"281-288\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2021-12-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/7d/f1/orr-13-281.PMC8684416.pdf\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Orthopedic Research and Reviews\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2147/ORR.S339222\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2021/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Orthopedic Research and Reviews","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/ORR.S339222","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Improving the Management of Patients with Osteoporosis Undergoing Spinal Fusion: The Need for a Bone Mineral Density-Matched Interbody Cage.
With an increasingly aging population globally, a confluence has emerged between the rising prevalence of degenerative spinal disease and osteoporosis. Fusion of the anterior spinal column remains the mainstay surgical intervention for many spinal degenerative disorders. However, decreased vertebral bone mineral density (BMD), quantitatively measured by dual x-ray absorptiometry (DXA), complicates treatment with surgical interbody fusion as weak underlying bone stock increases the risk of post-operative implant-related adverse events, including cage subsidence. There is a necessity for developing cages with advanced structural designs that incorporate bioengineering and architectural principles to tailor the interbody fusion device directly to the patient's BMD status. Specifically, lattice-designed cages that mimic the web-like structure of native cancellous bone have demonstrated excellent resistance to post-operative subsidence. This article provides an introductory profile of a spinal interbody implant designed intentionally to simulate the lattice structure of human cancellous bone, with a similar modulus of elasticity, and specialized to match a patient's bone status across the BMD continuum. The implant incorporates an open pore design where the degree of pore compactness directly corresponds to the patient's DXA-defined BMD status, including patients with osteoporosis.
期刊介绍:
Orthopedic Research and Reviews is an international, peer-reviewed, open-access journal focusing on the patho-physiology of the musculoskeletal system, trauma, surgery and other corrective interventions to restore mobility and function. Advances in new technologies, materials, techniques and pharmacological agents will be particularly welcome. Specific topics covered in the journal include: Patho-physiology and bioengineering, Technologies and materials science, Surgical techniques, including robotics, Trauma management and care, Treatment including pharmacological and non-pharmacological, Rehabilitation and Multidisciplinarian care approaches, Patient quality of life, satisfaction and preference, Health economic evaluations. The journal welcomes submitted papers covering original research, basic science and technology, clinical studies, reviews and evaluations, guidelines, expert opinion and commentary, case reports and extended reports.