{"title":"游泳设施浴缸中漂浮橡皮鸭的微生物污染及清洗方法评价。","authors":"Akiko Edagawa, Norihiro Matsuda, Toru Ogura, Kenichi Uezono, Shinji Izumiyama, Akira Fujii","doi":"10.4265/bio.26.187","DOIUrl":null,"url":null,"abstract":"<p><p>Microbiological contamination inside rubber ducks floating in the bathtub at a \"duck bath\" of a bathing facility was analyzed by examining bacterial and amoebic counts. The results of microbial tests, such as standard plate count, heterotrophic plate count and Legionella-LAMP (Loopmediated isothermal amplification) , showed that microbial contamination increased in the rubber ducks over time. When the ducks were washed with sodium hypochlorite, those microbial contaminations were not detected; but when the ducks were washed with an electrolyzed water, the standard plate counts and the heterotrophic plate counts were detected in the amount of 10<sup>3</sup> per duck in the wipe samples. Without proper washing of rubber ducks, bacteria and free-living amoeba can grow and colonize biofilms, and can thereby cause infection in humans. Also, microbial contamination inside ducks may reduce chlorination of the entire bathtub and cause bacterial infection such as Legionellosis from the bathtub water.</p>","PeriodicalId":8777,"journal":{"name":"Biocontrol science","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Microbial Contamination of Rubber Ducks Floating in Bathtubs of Bathing Facilities, and an Evaluation of Their Washing Methods.\",\"authors\":\"Akiko Edagawa, Norihiro Matsuda, Toru Ogura, Kenichi Uezono, Shinji Izumiyama, Akira Fujii\",\"doi\":\"10.4265/bio.26.187\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Microbiological contamination inside rubber ducks floating in the bathtub at a \\\"duck bath\\\" of a bathing facility was analyzed by examining bacterial and amoebic counts. The results of microbial tests, such as standard plate count, heterotrophic plate count and Legionella-LAMP (Loopmediated isothermal amplification) , showed that microbial contamination increased in the rubber ducks over time. When the ducks were washed with sodium hypochlorite, those microbial contaminations were not detected; but when the ducks were washed with an electrolyzed water, the standard plate counts and the heterotrophic plate counts were detected in the amount of 10<sup>3</sup> per duck in the wipe samples. Without proper washing of rubber ducks, bacteria and free-living amoeba can grow and colonize biofilms, and can thereby cause infection in humans. Also, microbial contamination inside ducks may reduce chlorination of the entire bathtub and cause bacterial infection such as Legionellosis from the bathtub water.</p>\",\"PeriodicalId\":8777,\"journal\":{\"name\":\"Biocontrol science\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biocontrol science\",\"FirstCategoryId\":\"99\",\"ListUrlMain\":\"https://doi.org/10.4265/bio.26.187\",\"RegionNum\":4,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOTECHNOLOGY & APPLIED MICROBIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biocontrol science","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.4265/bio.26.187","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOTECHNOLOGY & APPLIED MICROBIOLOGY","Score":null,"Total":0}
Microbial Contamination of Rubber Ducks Floating in Bathtubs of Bathing Facilities, and an Evaluation of Their Washing Methods.
Microbiological contamination inside rubber ducks floating in the bathtub at a "duck bath" of a bathing facility was analyzed by examining bacterial and amoebic counts. The results of microbial tests, such as standard plate count, heterotrophic plate count and Legionella-LAMP (Loopmediated isothermal amplification) , showed that microbial contamination increased in the rubber ducks over time. When the ducks were washed with sodium hypochlorite, those microbial contaminations were not detected; but when the ducks were washed with an electrolyzed water, the standard plate counts and the heterotrophic plate counts were detected in the amount of 103 per duck in the wipe samples. Without proper washing of rubber ducks, bacteria and free-living amoeba can grow and colonize biofilms, and can thereby cause infection in humans. Also, microbial contamination inside ducks may reduce chlorination of the entire bathtub and cause bacterial infection such as Legionellosis from the bathtub water.
期刊介绍:
The Biocontrol Science provides a medium for the publication of original articles, concise notes, and review articles on all aspects of science and technology of biocontrol.