Suheyb Bilge, Umut Demetoğlu, Senol Aslan, Hasan Onur Simsek
{"title":"使用动态导航的先导-钻导种植手术与完全导引种植手术的准确性比较。体外模型研究。","authors":"Suheyb Bilge, Umut Demetoğlu, Senol Aslan, Hasan Onur Simsek","doi":"10.1563/aaid-joi-D-20-00383","DOIUrl":null,"url":null,"abstract":"<p><p>The aims of the present study are to measure and compare dental implant deviations with fully guided and pilot drill-guided protocols using dynamic navigation systems in polyurethane models. The pilot drill-guided group was determined to be the study group and included 12 implant applications. In this group, the pilot hole was drilled with navigation guidance, and the procedure was completed freehandedly. In the control group, all drilling and implant placement steps were performed using the navigation system, and a total of 12 implants were placed. The pre- and postoperative images were compared to calculate the magnitude of implant deviation. The quantitative data of the 2 groups were compared using the independent-samples t test and Mann-Whitney U test. The analyses revealed that the length of the procedure differed significantly between the 2 groups (P < .001). The procedure duration was significantly shorter in the study group. The entry deviation values of the 2 groups were not significantly different (P = .079). The analysis revealed the apex deviation to be higher in the study group than in the control group (P = .003). However, the 2-dimensional vertical apex deviation values of the implants were not significantly different between groups (P = .068). Angular deviation was determined to be significantly higher in the study group (P < .001). In the present study, all implants were successfully placed in the models using a dynamic navigation system. The results of this study may be useful for future clinical studies.</p>","PeriodicalId":50101,"journal":{"name":"Journal of Oral Implantology","volume":" ","pages":"105-110"},"PeriodicalIF":1.5000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of the Accuracy of Pilot Drill-Guided and Fully Guided Implant Surgery With Dynamic Navigation: In Vitro Model Study.\",\"authors\":\"Suheyb Bilge, Umut Demetoğlu, Senol Aslan, Hasan Onur Simsek\",\"doi\":\"10.1563/aaid-joi-D-20-00383\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The aims of the present study are to measure and compare dental implant deviations with fully guided and pilot drill-guided protocols using dynamic navigation systems in polyurethane models. The pilot drill-guided group was determined to be the study group and included 12 implant applications. In this group, the pilot hole was drilled with navigation guidance, and the procedure was completed freehandedly. In the control group, all drilling and implant placement steps were performed using the navigation system, and a total of 12 implants were placed. The pre- and postoperative images were compared to calculate the magnitude of implant deviation. The quantitative data of the 2 groups were compared using the independent-samples t test and Mann-Whitney U test. The analyses revealed that the length of the procedure differed significantly between the 2 groups (P < .001). The procedure duration was significantly shorter in the study group. The entry deviation values of the 2 groups were not significantly different (P = .079). The analysis revealed the apex deviation to be higher in the study group than in the control group (P = .003). However, the 2-dimensional vertical apex deviation values of the implants were not significantly different between groups (P = .068). Angular deviation was determined to be significantly higher in the study group (P < .001). In the present study, all implants were successfully placed in the models using a dynamic navigation system. The results of this study may be useful for future clinical studies.</p>\",\"PeriodicalId\":50101,\"journal\":{\"name\":\"Journal of Oral Implantology\",\"volume\":\" \",\"pages\":\"105-110\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2025-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Oral Implantology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1563/aaid-joi-D-20-00383\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Oral Implantology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1563/aaid-joi-D-20-00383","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
摘要
本研究的目的是在聚氨酯模型中使用动态导航系统,测量并比较完全引导和先导-钻引导方案下的牙科种植体偏差。先导-钻导组被确定为研究组,包括 12 个种植体应用。在该组中,先导孔是在导航引导下钻出的,手术过程是徒手完成的。在对照组中,所有的钻孔和种植体植入步骤都是通过导航系统完成的,共植入了 12 个种植体。对比术前和术后图像,计算种植体偏差的大小。采用独立样本 t 检验和 Mann-Whitney U 检验比较两组的定量数据。分析结果显示,两组患者的手术持续时间存在显著差异(P < 0.001)。研究组的手术时间明显更短。两组的入口偏差值无明显差异(p = 0.079)。分析显示,研究组的顶点偏差高于对照组(p = 0.003)。然而,两组种植体的二维垂直顶偏差值没有明显差异(p = 0.068)。研究组的角度偏差明显更高(p < 0.001)。在本研究中,所有种植体都使用动态导航系统成功植入模型。本研究的结果可能对今后的临床研究有所帮助。
Comparison of the Accuracy of Pilot Drill-Guided and Fully Guided Implant Surgery With Dynamic Navigation: In Vitro Model Study.
The aims of the present study are to measure and compare dental implant deviations with fully guided and pilot drill-guided protocols using dynamic navigation systems in polyurethane models. The pilot drill-guided group was determined to be the study group and included 12 implant applications. In this group, the pilot hole was drilled with navigation guidance, and the procedure was completed freehandedly. In the control group, all drilling and implant placement steps were performed using the navigation system, and a total of 12 implants were placed. The pre- and postoperative images were compared to calculate the magnitude of implant deviation. The quantitative data of the 2 groups were compared using the independent-samples t test and Mann-Whitney U test. The analyses revealed that the length of the procedure differed significantly between the 2 groups (P < .001). The procedure duration was significantly shorter in the study group. The entry deviation values of the 2 groups were not significantly different (P = .079). The analysis revealed the apex deviation to be higher in the study group than in the control group (P = .003). However, the 2-dimensional vertical apex deviation values of the implants were not significantly different between groups (P = .068). Angular deviation was determined to be significantly higher in the study group (P < .001). In the present study, all implants were successfully placed in the models using a dynamic navigation system. The results of this study may be useful for future clinical studies.
期刊介绍:
The official publication of the American Academy of Implant Dentistry and of the American Academy of Implant Prosthodontics, is dedicated to providing valuable information to general dentists, oral surgeons, prosthodontists, periodontists, scientists, clinicians, laboratory owners and technicians, manufacturers, and educators. Implant basics, prosthetics, pharmaceuticals, the latest research in implantology, implant surgery, and advanced implant procedures are just some of the topics covered.