在射血分数正常的情况下,组织多普勒超声心动图a′速度与有创平均左房压相关。

IF 1.2 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Scandinavian Cardiovascular Journal Pub Date : 2022-12-01 Epub Date: 2022-02-09 DOI:10.1080/14017431.2022.2032317
Benny Johansson, Espen Fengsrud, Fredrik Lundin, Leif Bojö, Dritan Poci
{"title":"在射血分数正常的情况下,组织多普勒超声心动图a′速度与有创平均左房压相关。","authors":"Benny Johansson,&nbsp;Espen Fengsrud,&nbsp;Fredrik Lundin,&nbsp;Leif Bojö,&nbsp;Dritan Poci","doi":"10.1080/14017431.2022.2032317","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To evaluate the correlation of a' velocity by tissue-Doppler measurements with invasively measured mean left atrial pressure in patients with normal ejection fraction.</p><p><strong>Design: </strong>In this retrospective study, we evaluated the septal a', lateral a' and average a' velocity by tissue-Doppler echocardiography, in 125 in-hospital patients, 1-12 h before an elective pulmonary vein isolation due to intermittent atrial fibrillation, and compared to invasively measured mean left atrial pressure (LAP) during the invasive procedure. The patients, aged 35-81 years, had to be in sinus rhythm at both examinations, no atrial fibrillation during two procedures, no or mild valve disease and normal ejection fraction (>50%).</p><p><strong>Results: </strong>Invasively measured mean LAP correlated well to septal a' (<i>r</i> = -0.435), lateral a' (<i>r</i> = -0.473) and average a' velocity (<i>r</i> = -0.491). Normal mean LAP (≤12 mmHg) was found in 95 patients and elevated mean LAP (>12 mmHg) in 30 patients. The patients with elevated mean LAP had a lower septal a' velocity (6.5 ± 2.7 vs 8.6 ± 2.3 cm/s; <i>p</i> < .01), lateral a' velocity (5.9 ± 2.3 vs 8.6 ± 2.1 cm/s; <i>p</i> < .01) and average a' velocity (6.2 ± 2.4 vs 8.8 ± 2.1 cm/s; <i>p</i> < .01) compared to patients with normal mean LAP. Septal a', lateral a' and average a' velocity were good predictors of elevated mean LAP with AUC of 0.78, 0.83 and 0.82. Average a' velocity with cut-off < 7.25 cm/s had a sensitivity of 83% and a specificity of 77% to predict elevated mean LAP.</p><p><strong>Conclusion: </strong>The a' velocity is a good indicator of mean LAP and might be considered in the evaluation of left ventricle filling pressure in patients with normal ejection fraction.</p>","PeriodicalId":21383,"journal":{"name":"Scandinavian Cardiovascular Journal","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"The a' velocity by tissue-Doppler echocardiography correlates to invasive mean left atrial pressure in patients with normal ejection fraction.\",\"authors\":\"Benny Johansson,&nbsp;Espen Fengsrud,&nbsp;Fredrik Lundin,&nbsp;Leif Bojö,&nbsp;Dritan Poci\",\"doi\":\"10.1080/14017431.2022.2032317\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>To evaluate the correlation of a' velocity by tissue-Doppler measurements with invasively measured mean left atrial pressure in patients with normal ejection fraction.</p><p><strong>Design: </strong>In this retrospective study, we evaluated the septal a', lateral a' and average a' velocity by tissue-Doppler echocardiography, in 125 in-hospital patients, 1-12 h before an elective pulmonary vein isolation due to intermittent atrial fibrillation, and compared to invasively measured mean left atrial pressure (LAP) during the invasive procedure. The patients, aged 35-81 years, had to be in sinus rhythm at both examinations, no atrial fibrillation during two procedures, no or mild valve disease and normal ejection fraction (>50%).</p><p><strong>Results: </strong>Invasively measured mean LAP correlated well to septal a' (<i>r</i> = -0.435), lateral a' (<i>r</i> = -0.473) and average a' velocity (<i>r</i> = -0.491). Normal mean LAP (≤12 mmHg) was found in 95 patients and elevated mean LAP (>12 mmHg) in 30 patients. The patients with elevated mean LAP had a lower septal a' velocity (6.5 ± 2.7 vs 8.6 ± 2.3 cm/s; <i>p</i> < .01), lateral a' velocity (5.9 ± 2.3 vs 8.6 ± 2.1 cm/s; <i>p</i> < .01) and average a' velocity (6.2 ± 2.4 vs 8.8 ± 2.1 cm/s; <i>p</i> < .01) compared to patients with normal mean LAP. Septal a', lateral a' and average a' velocity were good predictors of elevated mean LAP with AUC of 0.78, 0.83 and 0.82. Average a' velocity with cut-off < 7.25 cm/s had a sensitivity of 83% and a specificity of 77% to predict elevated mean LAP.</p><p><strong>Conclusion: </strong>The a' velocity is a good indicator of mean LAP and might be considered in the evaluation of left ventricle filling pressure in patients with normal ejection fraction.</p>\",\"PeriodicalId\":21383,\"journal\":{\"name\":\"Scandinavian Cardiovascular Journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2022-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Scandinavian Cardiovascular Journal\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/14017431.2022.2032317\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/2/9 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scandinavian Cardiovascular Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/14017431.2022.2032317","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/2/9 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 1

摘要

目的:探讨在射血分数正常的情况下,组织多普勒血流速度与有创左房压的相关性。设计:在这项回顾性研究中,我们通过组织多普勒超声心动图评估了125例因间歇性房颤而进行选择性肺静脉隔离前1-12小时住院患者的室间隔a′、侧a′和平均a′速度,并与有创手术期间测量的平均左房压(LAP)进行了比较。患者年龄35-81岁,两次检查均处于窦性心律,两次手术均无房颤,无或轻度瓣膜疾病,射血分数正常(>50%)。结果:有创测量的平均LAP与中隔a′(r = -0.435)、侧位a′(r = -0.473)和平均a′速度(r = -0.491)相关良好。95例患者平均LAP正常(≤12 mmHg), 30例患者平均LAP升高(>12 mmHg)。平均LAP升高的患者中隔流速较低(6.5±2.7 vs 8.6±2.3 cm/s);p < . 01),横向速度(5.9±2.3 vs 8.6±2.1厘米/秒;P < 0.01),平均流速(6.2±2.4 vs 8.8±2.1 cm/s);p < 0.01)。间隔a′、侧a′和平均a′速度是平均LAP升高的良好预测因子,AUC分别为0.78、0.83和0.82。截止值< 7.25 cm/s的平均流速预测平均LAP升高的敏感性为83%,特异性为77%。结论:a′流速是衡量平均LAP的良好指标,可作为评价射血分数正常患者左室充盈压力的参考指标。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The a' velocity by tissue-Doppler echocardiography correlates to invasive mean left atrial pressure in patients with normal ejection fraction.

Objectives: To evaluate the correlation of a' velocity by tissue-Doppler measurements with invasively measured mean left atrial pressure in patients with normal ejection fraction.

Design: In this retrospective study, we evaluated the septal a', lateral a' and average a' velocity by tissue-Doppler echocardiography, in 125 in-hospital patients, 1-12 h before an elective pulmonary vein isolation due to intermittent atrial fibrillation, and compared to invasively measured mean left atrial pressure (LAP) during the invasive procedure. The patients, aged 35-81 years, had to be in sinus rhythm at both examinations, no atrial fibrillation during two procedures, no or mild valve disease and normal ejection fraction (>50%).

Results: Invasively measured mean LAP correlated well to septal a' (r = -0.435), lateral a' (r = -0.473) and average a' velocity (r = -0.491). Normal mean LAP (≤12 mmHg) was found in 95 patients and elevated mean LAP (>12 mmHg) in 30 patients. The patients with elevated mean LAP had a lower septal a' velocity (6.5 ± 2.7 vs 8.6 ± 2.3 cm/s; p < .01), lateral a' velocity (5.9 ± 2.3 vs 8.6 ± 2.1 cm/s; p < .01) and average a' velocity (6.2 ± 2.4 vs 8.8 ± 2.1 cm/s; p < .01) compared to patients with normal mean LAP. Septal a', lateral a' and average a' velocity were good predictors of elevated mean LAP with AUC of 0.78, 0.83 and 0.82. Average a' velocity with cut-off < 7.25 cm/s had a sensitivity of 83% and a specificity of 77% to predict elevated mean LAP.

Conclusion: The a' velocity is a good indicator of mean LAP and might be considered in the evaluation of left ventricle filling pressure in patients with normal ejection fraction.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Scandinavian Cardiovascular Journal
Scandinavian Cardiovascular Journal 医学-心血管系统
CiteScore
3.40
自引率
0.00%
发文量
56
审稿时长
6-12 weeks
期刊介绍: The principal aim of Scandinavian Cardiovascular Journal is to promote cardiovascular research that crosses the borders between disciplines. The journal is a forum for the entire field of cardiovascular research, basic and clinical including: • Cardiology - Interventional and non-invasive • Cardiovascular epidemiology • Cardiovascular anaesthesia and intensive care • Cardiovascular surgery • Cardiovascular radiology • Clinical physiology • Transplantation of thoracic organs
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信