{"title":"畜产品中阿苯达唑代谢物的LC-MS/MS测定","authors":"Ryo Okabe, Akiko Kubota, Satoru Nemoto, Mitsutoshi Aoyagi","doi":"10.3358/shokueishi.62.113","DOIUrl":null,"url":null,"abstract":"A method for determining albendazole metabolite (metabolite I) in livestock products using LC-MS/MS was proposed. Livestock samples were hydrolyzed with 6 mol/L HCl at 110℃ for an hour and defatted with ethyl acetate and n-hexane (1 : 1, v/v) mixture. Metabolite I was extracted with acetonitrile from the sample, and the extracts were salted out under basic conditions, allowing the acetonitrile layer to separate. The acetonitrile solution was cleaned up using a cartridge column packed with divinylbenzene-N-vinylpyrolidone copolymer bearing sulfo groups. The HPLC separation was conducted on an Inertsil ODS-4 column with a gradient formed from water containing 0.05% (v/v) formic acid and acetonitrile containing 0.05% (v/v) formic acid. To detect metabolite I, tandem mass spectrometry with positive ion electrospray ionization was used. Truenesses (n=5) of metabolite I from cattle meat, fat, liver, and milk spiked at the maximum residue limits or the 0.01 mg/kg were in the range from 83.6 to 97.9%, and the relative standard deviations were from 1.6 to 6.1%.","PeriodicalId":54373,"journal":{"name":"Food Hygiene and Safety Science","volume":"62 4","pages":"113-118"},"PeriodicalIF":0.2000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Determination of Albendazole Metabolite in Livestock Products Using LC-MS/MS].\",\"authors\":\"Ryo Okabe, Akiko Kubota, Satoru Nemoto, Mitsutoshi Aoyagi\",\"doi\":\"10.3358/shokueishi.62.113\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A method for determining albendazole metabolite (metabolite I) in livestock products using LC-MS/MS was proposed. Livestock samples were hydrolyzed with 6 mol/L HCl at 110℃ for an hour and defatted with ethyl acetate and n-hexane (1 : 1, v/v) mixture. Metabolite I was extracted with acetonitrile from the sample, and the extracts were salted out under basic conditions, allowing the acetonitrile layer to separate. The acetonitrile solution was cleaned up using a cartridge column packed with divinylbenzene-N-vinylpyrolidone copolymer bearing sulfo groups. The HPLC separation was conducted on an Inertsil ODS-4 column with a gradient formed from water containing 0.05% (v/v) formic acid and acetonitrile containing 0.05% (v/v) formic acid. To detect metabolite I, tandem mass spectrometry with positive ion electrospray ionization was used. Truenesses (n=5) of metabolite I from cattle meat, fat, liver, and milk spiked at the maximum residue limits or the 0.01 mg/kg were in the range from 83.6 to 97.9%, and the relative standard deviations were from 1.6 to 6.1%.\",\"PeriodicalId\":54373,\"journal\":{\"name\":\"Food Hygiene and Safety Science\",\"volume\":\"62 4\",\"pages\":\"113-118\"},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Food Hygiene and Safety Science\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.3358/shokueishi.62.113\",\"RegionNum\":4,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"FOOD SCIENCE & TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Food Hygiene and Safety Science","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.3358/shokueishi.62.113","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"FOOD SCIENCE & TECHNOLOGY","Score":null,"Total":0}
[Determination of Albendazole Metabolite in Livestock Products Using LC-MS/MS].
A method for determining albendazole metabolite (metabolite I) in livestock products using LC-MS/MS was proposed. Livestock samples were hydrolyzed with 6 mol/L HCl at 110℃ for an hour and defatted with ethyl acetate and n-hexane (1 : 1, v/v) mixture. Metabolite I was extracted with acetonitrile from the sample, and the extracts were salted out under basic conditions, allowing the acetonitrile layer to separate. The acetonitrile solution was cleaned up using a cartridge column packed with divinylbenzene-N-vinylpyrolidone copolymer bearing sulfo groups. The HPLC separation was conducted on an Inertsil ODS-4 column with a gradient formed from water containing 0.05% (v/v) formic acid and acetonitrile containing 0.05% (v/v) formic acid. To detect metabolite I, tandem mass spectrometry with positive ion electrospray ionization was used. Truenesses (n=5) of metabolite I from cattle meat, fat, liver, and milk spiked at the maximum residue limits or the 0.01 mg/kg were in the range from 83.6 to 97.9%, and the relative standard deviations were from 1.6 to 6.1%.