射线照相和电子工作长度比较。三种电子顶点定位器的体内研究。

IF 0.8 4区 医学 Q4 ENDOCRINOLOGY & METABOLISM
V Di Taranto, A Libonati, E Montemurro, G Gallusi
{"title":"射线照相和电子工作长度比较。三种电子顶点定位器的体内研究。","authors":"V Di Taranto,&nbsp;A Libonati,&nbsp;E Montemurro,&nbsp;G Gallusi","doi":"10.23812/21-3supp1-10","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this study is to compare the working length measured with Root ZX (EAL1), Propex II (EAL2) and Endo Analyzer Model 8005 (EAL3) with radiographic measurements during endodontic treatment. Fifty single canal teeth scheduled for endodontic treatment were selected for the study. After endodontic access preparation, pulp chamber was irrigated with 5mL of 5% sodium hypochlorite (NaOCl). The canal was scouted with a size 10 K-file introduced slightly over the apex to verify the canal patency. The working length (WL) was measured using all three EAL devices and radiographically. All measured working lengths were recorded and compared using ANOVA for repeated measures considering the multiple comparison of paired data Least Significant Difference (LSD). The WL mean values for EAL1 were 19.1 ± 1.7 mm; for EAL2 were 19.4 ± 1.7; for EAL3 were 19.4 ± 1.6 and for RG were 19.2 ± 1.7. The Pearson correlation coefficients indicated that the following correlation between electronic devices and radiographic WL: EAL1- 0.986, EAL2- 0.953 and EAL3- 0.931. Considering the mean values compared to radiographic measures, Root ZX gave better results than the other tested EAL devices. Endo Analyzer Model 8005 showed the worst performance.</p>","PeriodicalId":15084,"journal":{"name":"Journal of biological regulators and homeostatic agents","volume":"35 3 Suppl. 1","pages":"77-85"},"PeriodicalIF":0.8000,"publicationDate":"2021-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Radiographic and electronic working length comparison. An <i>in vivo</i> study of three Electronic Apex Locator devices.\",\"authors\":\"V Di Taranto,&nbsp;A Libonati,&nbsp;E Montemurro,&nbsp;G Gallusi\",\"doi\":\"10.23812/21-3supp1-10\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The aim of this study is to compare the working length measured with Root ZX (EAL1), Propex II (EAL2) and Endo Analyzer Model 8005 (EAL3) with radiographic measurements during endodontic treatment. Fifty single canal teeth scheduled for endodontic treatment were selected for the study. After endodontic access preparation, pulp chamber was irrigated with 5mL of 5% sodium hypochlorite (NaOCl). The canal was scouted with a size 10 K-file introduced slightly over the apex to verify the canal patency. The working length (WL) was measured using all three EAL devices and radiographically. All measured working lengths were recorded and compared using ANOVA for repeated measures considering the multiple comparison of paired data Least Significant Difference (LSD). The WL mean values for EAL1 were 19.1 ± 1.7 mm; for EAL2 were 19.4 ± 1.7; for EAL3 were 19.4 ± 1.6 and for RG were 19.2 ± 1.7. The Pearson correlation coefficients indicated that the following correlation between electronic devices and radiographic WL: EAL1- 0.986, EAL2- 0.953 and EAL3- 0.931. Considering the mean values compared to radiographic measures, Root ZX gave better results than the other tested EAL devices. Endo Analyzer Model 8005 showed the worst performance.</p>\",\"PeriodicalId\":15084,\"journal\":{\"name\":\"Journal of biological regulators and homeostatic agents\",\"volume\":\"35 3 Suppl. 1\",\"pages\":\"77-85\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2021-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of biological regulators and homeostatic agents\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.23812/21-3supp1-10\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENDOCRINOLOGY & METABOLISM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of biological regulators and homeostatic agents","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.23812/21-3supp1-10","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0

摘要

本研究的目的是比较根管治疗期间用Root ZX (EAL1)、Propex II (EAL2)和Endo Analyzer Model 8005 (EAL3)测量的工作长度与x线测量的工作长度。选择50颗单管牙进行牙髓治疗。根管通路准备完成后,用5mL 5%次氯酸钠(NaOCl)冲洗牙髓腔。用10k大小的锉刀在根管顶端稍上方检查根管是否通畅。工作长度(WL)测量使用所有三个EAL装置和放射照相。所有测量的工作长度都被记录下来,并考虑成对数据的多重比较,使用方差分析对重复测量进行比较,最小显著差异(LSD)。EAL1的WL平均值为19.1±1.7 mm;EAL2为19.4±1.7;EAL3为19.4±1.6,RG为19.2±1.7。Pearson相关系数显示,电子设备与x线影像WL的相关系数分别为EAL1- 0.986、EAL2- 0.953、EAL3- 0.931。考虑到与放射测量相比较的平均值,Root ZX给出了比其他测试EAL设备更好的结果。远藤分析仪8005型表现最差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Radiographic and electronic working length comparison. An in vivo study of three Electronic Apex Locator devices.

The aim of this study is to compare the working length measured with Root ZX (EAL1), Propex II (EAL2) and Endo Analyzer Model 8005 (EAL3) with radiographic measurements during endodontic treatment. Fifty single canal teeth scheduled for endodontic treatment were selected for the study. After endodontic access preparation, pulp chamber was irrigated with 5mL of 5% sodium hypochlorite (NaOCl). The canal was scouted with a size 10 K-file introduced slightly over the apex to verify the canal patency. The working length (WL) was measured using all three EAL devices and radiographically. All measured working lengths were recorded and compared using ANOVA for repeated measures considering the multiple comparison of paired data Least Significant Difference (LSD). The WL mean values for EAL1 were 19.1 ± 1.7 mm; for EAL2 were 19.4 ± 1.7; for EAL3 were 19.4 ± 1.6 and for RG were 19.2 ± 1.7. The Pearson correlation coefficients indicated that the following correlation between electronic devices and radiographic WL: EAL1- 0.986, EAL2- 0.953 and EAL3- 0.931. Considering the mean values compared to radiographic measures, Root ZX gave better results than the other tested EAL devices. Endo Analyzer Model 8005 showed the worst performance.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.20
自引率
15.60%
发文量
0
审稿时长
6 months
期刊介绍: Journal of Biological Regulators & Homeostatic Agents (IF 1.397) is a peer-reviewed journal published every 2 months. The journal publishes original papers describing research in the fields of experimental and clinical medicine, molecular biology, biochemistry, regulatory molecules, cellular immunology and pharmacology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信