多牙种植体直接印模技术中乙烯基聚醚和聚乙烯基硅氧烷印模材料的尺寸精度。

IF 0.9 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
Rohini Rajendran, N Gopi Chander, Kuttae Vishwanathan Anitha, Balasubramanian Muthukumar
{"title":"多牙种植体直接印模技术中乙烯基聚醚和聚乙烯基硅氧烷印模材料的尺寸精度。","authors":"Rohini Rajendran,&nbsp;N Gopi Chander,&nbsp;Kuttae Vishwanathan Anitha,&nbsp;Balasubramanian Muthukumar","doi":"10.26650/eor.20210110","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The present study compared the dimensional accuracy of vinyl polyether silicone (VPES) and polyvinyl siloxane (PVS) impression materials used for non-splinted (NS) and splinted (S) direct open-tray impression techniques for multiple implants inserted in simulated edentulous mandibles.</p><p><strong>Materials and methods: </strong>A mandibular stainless steel model with eight internal connections for implant analogs was fabricated to simulate a clinical scenario. The acrylic resin splinted and non-splinted direct impressions were obtained for both VPES and PVS materials. Seventy-two cast samples were divided into four groups based on the impression techniques and materials used. The dimensional accuracies of the casts were measured in three different axes using a computerized coordinate measuring machine (CMM), and were statistically compared.</p><p><strong>Results: </strong>The differences in the distortion values between the VPES and PVS impression materials were not statistically significant. Similarly, the differences between the splinted and non-splinted groups among the VPES and PVS materials were not statistically significant.</p><p><strong>Conclusion: </strong>The casts fabricated from VPS or PVS impression materials provide similar dimensional accuracy regardless of the implant splinting method.</p>","PeriodicalId":41993,"journal":{"name":"European Oral Research","volume":"55 2","pages":"54-59"},"PeriodicalIF":0.9000,"publicationDate":"2021-05-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/ba/ae/eor-055-054.PMC8244944.pdf","citationCount":"5","resultStr":"{\"title\":\"Dimensional accuracy of vinyl polyether and polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants.\",\"authors\":\"Rohini Rajendran,&nbsp;N Gopi Chander,&nbsp;Kuttae Vishwanathan Anitha,&nbsp;Balasubramanian Muthukumar\",\"doi\":\"10.26650/eor.20210110\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The present study compared the dimensional accuracy of vinyl polyether silicone (VPES) and polyvinyl siloxane (PVS) impression materials used for non-splinted (NS) and splinted (S) direct open-tray impression techniques for multiple implants inserted in simulated edentulous mandibles.</p><p><strong>Materials and methods: </strong>A mandibular stainless steel model with eight internal connections for implant analogs was fabricated to simulate a clinical scenario. The acrylic resin splinted and non-splinted direct impressions were obtained for both VPES and PVS materials. Seventy-two cast samples were divided into four groups based on the impression techniques and materials used. The dimensional accuracies of the casts were measured in three different axes using a computerized coordinate measuring machine (CMM), and were statistically compared.</p><p><strong>Results: </strong>The differences in the distortion values between the VPES and PVS impression materials were not statistically significant. Similarly, the differences between the splinted and non-splinted groups among the VPES and PVS materials were not statistically significant.</p><p><strong>Conclusion: </strong>The casts fabricated from VPS or PVS impression materials provide similar dimensional accuracy regardless of the implant splinting method.</p>\",\"PeriodicalId\":41993,\"journal\":{\"name\":\"European Oral Research\",\"volume\":\"55 2\",\"pages\":\"54-59\"},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2021-05-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/ba/ae/eor-055-054.PMC8244944.pdf\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Oral Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.26650/eor.20210110\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Oral Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26650/eor.20210110","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 5

摘要

目的:比较乙烯基聚醚硅氧烷(VPES)和聚氯乙烯硅氧烷(PVS)印模材料用于无夹板(NS)和夹板(S)直接开盘印模技术用于模拟无牙下颌骨多种植体植入的尺寸精度。材料和方法:制作具有8个内连接的下颌不锈钢模型来模拟临床场景。分别对VPES和PVS材料进行了丙烯酸树脂夹板和非夹板直接印模。72个铸造样品根据压模技术和所用材料分为四组。利用计算机坐标测量机(CMM)在三个不同的轴上测量铸件的尺寸精度,并进行统计比较。结果:VPES与PVS印模材料的畸变值差异无统计学意义。同样,在VPES和PVS材料中,夹板组和非夹板组之间的差异无统计学意义。结论:使用VPS或PVS印模材料制作的模体无论采用何种夹板方法均可提供相似的尺寸精度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Dimensional accuracy of vinyl polyether and polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants.

Dimensional accuracy of vinyl polyether and polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants.

Dimensional accuracy of vinyl polyether and polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants.

Dimensional accuracy of vinyl polyether and polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants.

Purpose: The present study compared the dimensional accuracy of vinyl polyether silicone (VPES) and polyvinyl siloxane (PVS) impression materials used for non-splinted (NS) and splinted (S) direct open-tray impression techniques for multiple implants inserted in simulated edentulous mandibles.

Materials and methods: A mandibular stainless steel model with eight internal connections for implant analogs was fabricated to simulate a clinical scenario. The acrylic resin splinted and non-splinted direct impressions were obtained for both VPES and PVS materials. Seventy-two cast samples were divided into four groups based on the impression techniques and materials used. The dimensional accuracies of the casts were measured in three different axes using a computerized coordinate measuring machine (CMM), and were statistically compared.

Results: The differences in the distortion values between the VPES and PVS impression materials were not statistically significant. Similarly, the differences between the splinted and non-splinted groups among the VPES and PVS materials were not statistically significant.

Conclusion: The casts fabricated from VPS or PVS impression materials provide similar dimensional accuracy regardless of the implant splinting method.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
European Oral Research
European Oral Research DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
1.60
自引率
0.00%
发文量
23
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信