反复使用植入机头对输出扭矩的影响:一项体外研究。

IF 2.7 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Journal of Advanced Prosthodontics Pub Date : 2021-06-01 Epub Date: 2021-06-25 DOI:10.4047/jap.2021.13.3.136
KeunBaDa Son, Young-Tak Son, Ji-Young Kim, Jae-Mok Lee, Won-Jae Yu, Jin-Wook Kim, Kyu-Bok Lee
{"title":"反复使用植入机头对输出扭矩的影响:一项体外研究。","authors":"KeunBaDa Son,&nbsp;Young-Tak Son,&nbsp;Ji-Young Kim,&nbsp;Jae-Mok Lee,&nbsp;Won-Jae Yu,&nbsp;Jin-Wook Kim,&nbsp;Kyu-Bok Lee","doi":"10.4047/jap.2021.13.3.136","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to evaluate the effect of repeated use of an implant handpiece under an implant placement torque (35 Ncm) and overloading torque condition (50 Ncm) on an output torque.</p><p><strong>Materials and methods: </strong>Two types of implant handpiece systems (Surgicpro/X-DSG20L [NSK, Kanuma, Japan] and SIP20/CRB46LN [SAESHIN, Daegu, South Korea]) were used. The output torque was measured using a digital torque gauge. The height and angle (x, y, and z axes) of the digital torque gauge and implant handpiece were adjusted through a jig for passive connection. The experiment was conducted under the setting torque value of 35 Ncm (implant placement torque) and 50 Ncm (overloading torque condition) and 30 times per set; a total of 5 sets were performed (N = 150). For statistical analysis, the difference between the groups was analyzed using the Mann-Whitney U test and the Friedman test was used to confirm the change in output torque (α=.05).</p><p><strong>Results: </strong>NSK and SAESHIN implant handpieces showed significant differences in output torque results at the setting torques of 35 Ncm and 50 Ncm (<i>P</i><.001). The type of implant handpiece and repeated use influenced the output torque (<i>P</i><.001).</p><p><strong>Conclusion: </strong>There may be a difference between the setting torque and actual output torque due to repeated use, and the implant handpiece should be managed and repaired during long-term use. In addition, for successful implant results in dental clinics, the output torque of the implant handpiece system should be checked before implant placement.</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2021-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/8b/55/jap-13-136.PMC8250193.pdf","citationCount":"0","resultStr":"{\"title\":\"Effect of repeated use of an implant handpiece on an output torque: An <i>in-vitro</i> study.\",\"authors\":\"KeunBaDa Son,&nbsp;Young-Tak Son,&nbsp;Ji-Young Kim,&nbsp;Jae-Mok Lee,&nbsp;Won-Jae Yu,&nbsp;Jin-Wook Kim,&nbsp;Kyu-Bok Lee\",\"doi\":\"10.4047/jap.2021.13.3.136\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This study aimed to evaluate the effect of repeated use of an implant handpiece under an implant placement torque (35 Ncm) and overloading torque condition (50 Ncm) on an output torque.</p><p><strong>Materials and methods: </strong>Two types of implant handpiece systems (Surgicpro/X-DSG20L [NSK, Kanuma, Japan] and SIP20/CRB46LN [SAESHIN, Daegu, South Korea]) were used. The output torque was measured using a digital torque gauge. The height and angle (x, y, and z axes) of the digital torque gauge and implant handpiece were adjusted through a jig for passive connection. The experiment was conducted under the setting torque value of 35 Ncm (implant placement torque) and 50 Ncm (overloading torque condition) and 30 times per set; a total of 5 sets were performed (N = 150). For statistical analysis, the difference between the groups was analyzed using the Mann-Whitney U test and the Friedman test was used to confirm the change in output torque (α=.05).</p><p><strong>Results: </strong>NSK and SAESHIN implant handpieces showed significant differences in output torque results at the setting torques of 35 Ncm and 50 Ncm (<i>P</i><.001). The type of implant handpiece and repeated use influenced the output torque (<i>P</i><.001).</p><p><strong>Conclusion: </strong>There may be a difference between the setting torque and actual output torque due to repeated use, and the implant handpiece should be managed and repaired during long-term use. In addition, for successful implant results in dental clinics, the output torque of the implant handpiece system should be checked before implant placement.</p>\",\"PeriodicalId\":51291,\"journal\":{\"name\":\"Journal of Advanced Prosthodontics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2021-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/8b/55/jap-13-136.PMC8250193.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Advanced Prosthodontics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4047/jap.2021.13.3.136\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2021/6/25 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Advanced Prosthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4047/jap.2021.13.3.136","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/6/25 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究旨在评估在种植体放置扭矩(35 Ncm)和过载扭矩(50 Ncm)条件下重复使用种植体机头对输出扭矩的影响。材料和方法:使用两种种植体手机系统(Surgicpro/X-DSG20L [NSK, Kanuma,日本]和SIP20/CRB46LN [SAESHIN,大邱,韩国])。输出扭矩采用数字扭矩计测量。数字式扭矩计和植入机头的高度和角度(x、y、z轴)通过夹具进行被动连接。实验在35 Ncm(植入扭矩)和50 Ncm(过载扭矩)设置扭矩值下进行,每组30次;共进行5组(N = 150)。统计学上,采用Mann-Whitney U检验分析组间差异,采用Friedman检验确认输出扭矩变化(α= 0.05)。结果:NSK和SAESHIN种植机头在设置力矩为35 Ncm和50 Ncm时的输出力矩结果有显著差异(ppp)。结论:由于反复使用,设置力矩与实际输出力矩可能存在差异,长期使用应对种植机头进行管理和修复。此外,为了在牙科诊所种植成功,在种植体放置前应检查种植机头系统的输出扭矩。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Effect of repeated use of an implant handpiece on an output torque: An <i>in-vitro</i> study.

Effect of repeated use of an implant handpiece on an output torque: An <i>in-vitro</i> study.

Effect of repeated use of an implant handpiece on an output torque: An <i>in-vitro</i> study.

Effect of repeated use of an implant handpiece on an output torque: An in-vitro study.

Purpose: This study aimed to evaluate the effect of repeated use of an implant handpiece under an implant placement torque (35 Ncm) and overloading torque condition (50 Ncm) on an output torque.

Materials and methods: Two types of implant handpiece systems (Surgicpro/X-DSG20L [NSK, Kanuma, Japan] and SIP20/CRB46LN [SAESHIN, Daegu, South Korea]) were used. The output torque was measured using a digital torque gauge. The height and angle (x, y, and z axes) of the digital torque gauge and implant handpiece were adjusted through a jig for passive connection. The experiment was conducted under the setting torque value of 35 Ncm (implant placement torque) and 50 Ncm (overloading torque condition) and 30 times per set; a total of 5 sets were performed (N = 150). For statistical analysis, the difference between the groups was analyzed using the Mann-Whitney U test and the Friedman test was used to confirm the change in output torque (α=.05).

Results: NSK and SAESHIN implant handpieces showed significant differences in output torque results at the setting torques of 35 Ncm and 50 Ncm (P<.001). The type of implant handpiece and repeated use influenced the output torque (P<.001).

Conclusion: There may be a difference between the setting torque and actual output torque due to repeated use, and the implant handpiece should be managed and repaired during long-term use. In addition, for successful implant results in dental clinics, the output torque of the implant handpiece system should be checked before implant placement.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Advanced Prosthodontics
Journal of Advanced Prosthodontics DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
4.70
自引率
3.80%
发文量
25
期刊介绍: This journal aims to convey scientific and clinical progress in the field of prosthodontics and its related areas to many dental communities concerned with esthetic and functional restorations, occlusion, implants, prostheses, and biomaterials related to prosthodontics. This journal publishes • Original research data of high scientific merit in the field of diagnosis, function, esthetics and stomatognathic physiology related to prosthodontic rehabilitation, physiology and mechanics of occlusion, mechanical and biologic aspects of prosthodontic materials including dental implants. • Review articles by experts on controversies and new developments in prosthodontics. • Case reports if they provide or document new fundamental knowledge.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信