Ahmed A-H Abood, Juozas Petruskevicius, Björn Vogt, Adrien Frommer, Robert Rödl, Jan Duedal Rölfing
{"title":"术中评估下肢冠状位对齐的关节角度工具。","authors":"Ahmed A-H Abood, Juozas Petruskevicius, Björn Vogt, Adrien Frommer, Robert Rödl, Jan Duedal Rölfing","doi":"10.5005/jp-journals-10080-1511","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>Presentation of the joint angle tool (JAT), a low-cost goniometer for intraoperative assessment of the lower limb alignment.</p><p><strong>Background: </strong>Intraoperative assessment of coronal alignment is important when performing corrective osteotomies around the knee and ankle, limb lengthening, and trauma surgery. JAT provides surgeons with information about the anatomic and mechanical axes intraoperatively based on true anteroposterior radiographs.</p><p><strong>Technique: </strong>JAT consists of pre-printed joint orientation angles of the anatomic and mechanical axis including normal variations on a plastic sheet. It is placed on the screen of the image intensifier after obtaining a true anteroposterior image. The pre-printed joint orientation angles can assist the surgeons intraoperatively in achieving the pre-planned axis correction. Here, its feasibility is demonstrated in four cases.</p><p><strong>Conclusion and clinical significance: </strong>JAT is a modified goniometer that allows intraoperative assessment of the mechanical and anatomic axis. JAT is applicable throughout the entire surgical procedure irrespective of the method of internal fixation and may provide additional reassurance of correct alignment. JAT consists of a plastic sheet with printed joint orientation angles and their normal variation. JAT is freely available from profeedback.dk/JAT/JAT.pdf for use and modification according to the Creative Commons license (CC BY-SA 4.0) if this paper is attributed.</p><p><strong>How to cite this article: </strong>Abood AA-H, Petruskevicius J, Vogt B, <i>et al.</i> The Joint Angle Tool for Intraoperative Assessment of Coronal Alignment of the Lower Limb. Strategies Trauma Limb Reconstr 2020;15(3):169-173.</p>","PeriodicalId":21979,"journal":{"name":"Strategies in Trauma and Limb Reconstruction","volume":"15 3","pages":"169-173"},"PeriodicalIF":1.0000,"publicationDate":"2020-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/35/5f/stlr-15-169.PMC8121113.pdf","citationCount":"2","resultStr":"{\"title\":\"The Joint Angle Tool for Intraoperative Assessment of Coronal Alignment of the Lower Limb.\",\"authors\":\"Ahmed A-H Abood, Juozas Petruskevicius, Björn Vogt, Adrien Frommer, Robert Rödl, Jan Duedal Rölfing\",\"doi\":\"10.5005/jp-journals-10080-1511\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aim: </strong>Presentation of the joint angle tool (JAT), a low-cost goniometer for intraoperative assessment of the lower limb alignment.</p><p><strong>Background: </strong>Intraoperative assessment of coronal alignment is important when performing corrective osteotomies around the knee and ankle, limb lengthening, and trauma surgery. JAT provides surgeons with information about the anatomic and mechanical axes intraoperatively based on true anteroposterior radiographs.</p><p><strong>Technique: </strong>JAT consists of pre-printed joint orientation angles of the anatomic and mechanical axis including normal variations on a plastic sheet. It is placed on the screen of the image intensifier after obtaining a true anteroposterior image. The pre-printed joint orientation angles can assist the surgeons intraoperatively in achieving the pre-planned axis correction. Here, its feasibility is demonstrated in four cases.</p><p><strong>Conclusion and clinical significance: </strong>JAT is a modified goniometer that allows intraoperative assessment of the mechanical and anatomic axis. JAT is applicable throughout the entire surgical procedure irrespective of the method of internal fixation and may provide additional reassurance of correct alignment. JAT consists of a plastic sheet with printed joint orientation angles and their normal variation. JAT is freely available from profeedback.dk/JAT/JAT.pdf for use and modification according to the Creative Commons license (CC BY-SA 4.0) if this paper is attributed.</p><p><strong>How to cite this article: </strong>Abood AA-H, Petruskevicius J, Vogt B, <i>et al.</i> The Joint Angle Tool for Intraoperative Assessment of Coronal Alignment of the Lower Limb. Strategies Trauma Limb Reconstr 2020;15(3):169-173.</p>\",\"PeriodicalId\":21979,\"journal\":{\"name\":\"Strategies in Trauma and Limb Reconstruction\",\"volume\":\"15 3\",\"pages\":\"169-173\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2020-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/35/5f/stlr-15-169.PMC8121113.pdf\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Strategies in Trauma and Limb Reconstruction\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5005/jp-journals-10080-1511\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Strategies in Trauma and Limb Reconstruction","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5005/jp-journals-10080-1511","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
The Joint Angle Tool for Intraoperative Assessment of Coronal Alignment of the Lower Limb.
Aim: Presentation of the joint angle tool (JAT), a low-cost goniometer for intraoperative assessment of the lower limb alignment.
Background: Intraoperative assessment of coronal alignment is important when performing corrective osteotomies around the knee and ankle, limb lengthening, and trauma surgery. JAT provides surgeons with information about the anatomic and mechanical axes intraoperatively based on true anteroposterior radiographs.
Technique: JAT consists of pre-printed joint orientation angles of the anatomic and mechanical axis including normal variations on a plastic sheet. It is placed on the screen of the image intensifier after obtaining a true anteroposterior image. The pre-printed joint orientation angles can assist the surgeons intraoperatively in achieving the pre-planned axis correction. Here, its feasibility is demonstrated in four cases.
Conclusion and clinical significance: JAT is a modified goniometer that allows intraoperative assessment of the mechanical and anatomic axis. JAT is applicable throughout the entire surgical procedure irrespective of the method of internal fixation and may provide additional reassurance of correct alignment. JAT consists of a plastic sheet with printed joint orientation angles and their normal variation. JAT is freely available from profeedback.dk/JAT/JAT.pdf for use and modification according to the Creative Commons license (CC BY-SA 4.0) if this paper is attributed.
How to cite this article: Abood AA-H, Petruskevicius J, Vogt B, et al. The Joint Angle Tool for Intraoperative Assessment of Coronal Alignment of the Lower Limb. Strategies Trauma Limb Reconstr 2020;15(3):169-173.
期刊介绍:
Strategies in Trauma and Limb Reconstruction is dedicated to surgeons, allied medical professionals and researchers in the field of orthopaedics and trauma. The scope of the journal is to discuss the fields of skeletal injury, and the complications thereof, congenital and acquired limb deformities and deficiencies, and orthopaedic-related infection, together with their surgical and non-surgical treatments. The journal publishes original articles, reviews, case reports, descriptions of new or recognised treatment techniques, forum discussions of clinical scenarios and relevant correspondence. It aims to provide a widely accessible source of useful information to practitioners in the field through the problem- or technique-based approach of published articles.