{"title":"伴有或不伴有融合性发育不良性眼震的弱视患者的单眼和双眼视觉功能障碍。","authors":"Jordan Murray, Kiran Garg, Fatema Ghasia","doi":"10.2147/EB.S300454","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of the study is to examine the association between amblyopia type and the presence of nystagmus on binocular and monocular functions of the fellow (FE) and amblyopic eye (AE).</p><p><strong>Methods: </strong>We recruited 19 controls and 44 amblyopes (anisometropes=13, strabismic=10, mixed=21). We measured visual, grating, and vernier acuities and high/low spatial frequency (SF) contrast sensitivities in each eye using a staircase method. Stereoacuity was measured with the Titmus fly test. We recorded fixation eye movements (FEM) using high-resolution video-oculography. Subjects were classified as having either no nystagmus (n=18), fusion maldevelopment nystagmus syndrome (FMNS) (n=12), or nystagmus without any structural anomalies that does not meet the criteria for FMNS or infantile nystagmus (n=14).</p><p><strong>Results: </strong>Analysis of visual function by clinical amblyopia type showed that patients with strabismus/mixed amblyopia (F (2,54)=9.5, p<0.001) were more likely to have poor stereopsis while controlling for AE grating acuity deficit. The FE of patients with anisometropia had greater contrast sensitivity deficits at low (F (2,43)=4.4, p=0.018) and high SF (F (2,42)=10.1, p<0.001). Analysis of visual function by FEM characteristics (low SF: (F (3,43)=4.3, p=0.010) and high SF: (F (3,42)=7.1, p=0.001) showed that the FE of patients with FMNS had worse low and high SF contrast sensitivities, whereas those without FMNS had greater contrast sensitivity deficits only at high SF compared to controls. Patients with FMNS (F (3,54) = 12.9, p<0.001) were more likely to have poor stereopsis while controlling for AE grating acuity deficit compared to patients without FMNS. All amblyopic patients had worse high SF contrast sensitivity of the AE irrespective of type or FEM characteristics (Type = F (2,43)=8.8, p=0.001; FEM characteristics= F (3,43)=5.1, p=0.004).</p><p><strong>Conclusion: </strong>The presence of FMNS in patients with strabismic/mixed amblyopia is associated with poor/absent stereopsis. FE deficits vary across amblyopia type. Like FEM abnormalities, visual function deficits are seen in the FE of patients with and without nystagmus.</p>","PeriodicalId":51844,"journal":{"name":"Eye and Brain","volume":"13 ","pages":"99-109"},"PeriodicalIF":3.1000,"publicationDate":"2021-04-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/49/81/eb-13-99.PMC8089081.pdf","citationCount":"0","resultStr":"{\"title\":\"Monocular and Binocular Visual Function Deficits in Amblyopic Patients with and without Fusion Maldevelopment Nystagmus.\",\"authors\":\"Jordan Murray, Kiran Garg, Fatema Ghasia\",\"doi\":\"10.2147/EB.S300454\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The aim of the study is to examine the association between amblyopia type and the presence of nystagmus on binocular and monocular functions of the fellow (FE) and amblyopic eye (AE).</p><p><strong>Methods: </strong>We recruited 19 controls and 44 amblyopes (anisometropes=13, strabismic=10, mixed=21). We measured visual, grating, and vernier acuities and high/low spatial frequency (SF) contrast sensitivities in each eye using a staircase method. Stereoacuity was measured with the Titmus fly test. We recorded fixation eye movements (FEM) using high-resolution video-oculography. Subjects were classified as having either no nystagmus (n=18), fusion maldevelopment nystagmus syndrome (FMNS) (n=12), or nystagmus without any structural anomalies that does not meet the criteria for FMNS or infantile nystagmus (n=14).</p><p><strong>Results: </strong>Analysis of visual function by clinical amblyopia type showed that patients with strabismus/mixed amblyopia (F (2,54)=9.5, p<0.001) were more likely to have poor stereopsis while controlling for AE grating acuity deficit. The FE of patients with anisometropia had greater contrast sensitivity deficits at low (F (2,43)=4.4, p=0.018) and high SF (F (2,42)=10.1, p<0.001). Analysis of visual function by FEM characteristics (low SF: (F (3,43)=4.3, p=0.010) and high SF: (F (3,42)=7.1, p=0.001) showed that the FE of patients with FMNS had worse low and high SF contrast sensitivities, whereas those without FMNS had greater contrast sensitivity deficits only at high SF compared to controls. Patients with FMNS (F (3,54) = 12.9, p<0.001) were more likely to have poor stereopsis while controlling for AE grating acuity deficit compared to patients without FMNS. All amblyopic patients had worse high SF contrast sensitivity of the AE irrespective of type or FEM characteristics (Type = F (2,43)=8.8, p=0.001; FEM characteristics= F (3,43)=5.1, p=0.004).</p><p><strong>Conclusion: </strong>The presence of FMNS in patients with strabismic/mixed amblyopia is associated with poor/absent stereopsis. FE deficits vary across amblyopia type. Like FEM abnormalities, visual function deficits are seen in the FE of patients with and without nystagmus.</p>\",\"PeriodicalId\":51844,\"journal\":{\"name\":\"Eye and Brain\",\"volume\":\"13 \",\"pages\":\"99-109\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2021-04-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/49/81/eb-13-99.PMC8089081.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Eye and Brain\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2147/EB.S300454\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2021/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eye and Brain","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/EB.S300454","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/1/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
Monocular and Binocular Visual Function Deficits in Amblyopic Patients with and without Fusion Maldevelopment Nystagmus.
Purpose: The aim of the study is to examine the association between amblyopia type and the presence of nystagmus on binocular and monocular functions of the fellow (FE) and amblyopic eye (AE).
Methods: We recruited 19 controls and 44 amblyopes (anisometropes=13, strabismic=10, mixed=21). We measured visual, grating, and vernier acuities and high/low spatial frequency (SF) contrast sensitivities in each eye using a staircase method. Stereoacuity was measured with the Titmus fly test. We recorded fixation eye movements (FEM) using high-resolution video-oculography. Subjects were classified as having either no nystagmus (n=18), fusion maldevelopment nystagmus syndrome (FMNS) (n=12), or nystagmus without any structural anomalies that does not meet the criteria for FMNS or infantile nystagmus (n=14).
Results: Analysis of visual function by clinical amblyopia type showed that patients with strabismus/mixed amblyopia (F (2,54)=9.5, p<0.001) were more likely to have poor stereopsis while controlling for AE grating acuity deficit. The FE of patients with anisometropia had greater contrast sensitivity deficits at low (F (2,43)=4.4, p=0.018) and high SF (F (2,42)=10.1, p<0.001). Analysis of visual function by FEM characteristics (low SF: (F (3,43)=4.3, p=0.010) and high SF: (F (3,42)=7.1, p=0.001) showed that the FE of patients with FMNS had worse low and high SF contrast sensitivities, whereas those without FMNS had greater contrast sensitivity deficits only at high SF compared to controls. Patients with FMNS (F (3,54) = 12.9, p<0.001) were more likely to have poor stereopsis while controlling for AE grating acuity deficit compared to patients without FMNS. All amblyopic patients had worse high SF contrast sensitivity of the AE irrespective of type or FEM characteristics (Type = F (2,43)=8.8, p=0.001; FEM characteristics= F (3,43)=5.1, p=0.004).
Conclusion: The presence of FMNS in patients with strabismic/mixed amblyopia is associated with poor/absent stereopsis. FE deficits vary across amblyopia type. Like FEM abnormalities, visual function deficits are seen in the FE of patients with and without nystagmus.
期刊介绍:
Eye and Brain is an international, peer-reviewed, open access journal focusing on basic research, clinical findings, and expert reviews in the field of visual science and neuro-ophthalmology. The journal’s unique focus is the link between two well-known visual centres, the eye and the brain, with an emphasis on the importance of such connections. All aspects of clinical and especially basic research on the visual system are addressed within the journal as well as significant future directions in vision research and therapeutic measures. This unique journal focuses on neurological aspects of vision – both physiological and pathological. The scope of the journal spans from the cornea to the associational visual cortex and all the visual centers in between. Topics range from basic biological mechanisms to therapeutic treatment, from simple organisms to humans, and utilizing techniques from molecular biology to behavior. The journal especially welcomes primary research articles or review papers that make the connection between the eye and the brain. Specific areas covered in the journal include: Physiology and pathophysiology of visual centers, Eye movement disorders and strabismus, Cellular, biochemical, and molecular features of the visual system, Structural and functional organization of the eye and of the visual cortex, Metabolic demands of the visual system, Diseases and disorders with neuro-ophthalmic manifestations, Clinical and experimental neuro-ophthalmology and visual system pathologies, Epidemiological studies.