站立镇静马头部位置对颈动脉内外压的影响。

IF 1.1 4区 农林科学 Q2 Veterinary
Stacy R Caffey, Caleb M Lund, Kelly D Farnsworth, Boel A Fransson, Claude A Ragle
{"title":"站立镇静马头部位置对颈动脉内外压的影响。","authors":"Stacy R Caffey,&nbsp;Caleb M Lund,&nbsp;Kelly D Farnsworth,&nbsp;Boel A Fransson,&nbsp;Claude A Ragle","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The effects of head position on internal carotid artery (ICA) and external carotid artery (ECA) pressures in standing sedated horses were evaluated in this study. The common carotid artery (CCA) was catheterized in 6 horses using an ultrasound-guided technique to facilitate placement of a pressure transducer within the ICA and ECA at the level of the guttural pouch. Transducer position was confirmed by endoscopic visualization. Mean arterial pressure (MAP) was measured with horses in both a head-up and head-down position. The dorsal metatarsal artery was catheterized as a control. Maintaining a head-up position decreased MAP in both the ICA (median: 75.21 mmHg) and ECA (median: 79.43 mmHg), relative to the head-down position (ICA median: 104.65 mmHg; ECA median: 102.26 mmHg). Mean arterial pressure in the dorsal metatarsal artery was not affected by head position. The head-up position resulted in lower arterial pressures in both the ICA and ECA (<i>P</i> = 0.03) compared with the head-down position in standing sedated horses.</p>","PeriodicalId":9550,"journal":{"name":"Canadian journal of veterinary research = Revue canadienne de recherche veterinaire","volume":"85 2","pages":"127-130"},"PeriodicalIF":1.1000,"publicationDate":"2021-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7995541/pdf/cjvr_02_127.pdf","citationCount":"0","resultStr":"{\"title\":\"Effects of head position on internal and external carotid pressures in standing sedated horses.\",\"authors\":\"Stacy R Caffey,&nbsp;Caleb M Lund,&nbsp;Kelly D Farnsworth,&nbsp;Boel A Fransson,&nbsp;Claude A Ragle\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The effects of head position on internal carotid artery (ICA) and external carotid artery (ECA) pressures in standing sedated horses were evaluated in this study. The common carotid artery (CCA) was catheterized in 6 horses using an ultrasound-guided technique to facilitate placement of a pressure transducer within the ICA and ECA at the level of the guttural pouch. Transducer position was confirmed by endoscopic visualization. Mean arterial pressure (MAP) was measured with horses in both a head-up and head-down position. The dorsal metatarsal artery was catheterized as a control. Maintaining a head-up position decreased MAP in both the ICA (median: 75.21 mmHg) and ECA (median: 79.43 mmHg), relative to the head-down position (ICA median: 104.65 mmHg; ECA median: 102.26 mmHg). Mean arterial pressure in the dorsal metatarsal artery was not affected by head position. The head-up position resulted in lower arterial pressures in both the ICA and ECA (<i>P</i> = 0.03) compared with the head-down position in standing sedated horses.</p>\",\"PeriodicalId\":9550,\"journal\":{\"name\":\"Canadian journal of veterinary research = Revue canadienne de recherche veterinaire\",\"volume\":\"85 2\",\"pages\":\"127-130\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2021-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7995541/pdf/cjvr_02_127.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Canadian journal of veterinary research = Revue canadienne de recherche veterinaire\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"\",\"RegionNum\":4,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Veterinary\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Canadian journal of veterinary research = Revue canadienne de recherche veterinaire","FirstCategoryId":"97","ListUrlMain":"","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Veterinary","Score":null,"Total":0}
引用次数: 0

摘要

本研究评估了站立镇静马匹头部位置对颈内动脉(ICA)和颈外动脉(ECA)压力的影响。在6匹马的颈总动脉(CCA)导管中使用超声引导技术,以便在ICA和ECA的喉部袋水平放置压力传感器。通过内窥镜观察确定换能器位置。平均动脉压(MAP)测量马匹平头和平头两种姿势。跖背动脉插管作为对照。相对于俯卧位(ICA中位数:104.65 mmHg),保持俯卧位降低了ICA(中位数:75.21 mmHg)和ECA(中位数:79.43 mmHg)的MAP。ECA中位数:102.26 mmHg)。跖背动脉的平均动脉压不受头部位置的影响。与站立镇静马的头朝上体位相比,站立镇静马的头朝上体位动脉压较低(P = 0.03)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effects of head position on internal and external carotid pressures in standing sedated horses.

The effects of head position on internal carotid artery (ICA) and external carotid artery (ECA) pressures in standing sedated horses were evaluated in this study. The common carotid artery (CCA) was catheterized in 6 horses using an ultrasound-guided technique to facilitate placement of a pressure transducer within the ICA and ECA at the level of the guttural pouch. Transducer position was confirmed by endoscopic visualization. Mean arterial pressure (MAP) was measured with horses in both a head-up and head-down position. The dorsal metatarsal artery was catheterized as a control. Maintaining a head-up position decreased MAP in both the ICA (median: 75.21 mmHg) and ECA (median: 79.43 mmHg), relative to the head-down position (ICA median: 104.65 mmHg; ECA median: 102.26 mmHg). Mean arterial pressure in the dorsal metatarsal artery was not affected by head position. The head-up position resulted in lower arterial pressures in both the ICA and ECA (P = 0.03) compared with the head-down position in standing sedated horses.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.80
自引率
0.00%
发文量
58
审稿时长
>24 weeks
期刊介绍: The Canadian Journal of Veterinary Research, published by the Canadian Veterinary Medical Association, is Canada''s only veterinary research publication. This quarterly peer-reviewed online-only journal has earned a wide international readership through the publishing of high quality scientific papers in the field of veterinary medicine. The Journal publishes the results of original research in veterinary and comparative medicine.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信