{"title":"牙科单位水管中的生物膜。","authors":"Gunnar Dahlen","doi":"10.1159/000510195","DOIUrl":null,"url":null,"abstract":"<p><p>Biofilm formation has become a significant problem in dental unit water lines (DUWLs). The formation of biofilms and microbial growth in DUWLs leads to an unacceptably high number of microorganisms in the water used for spraying, cooling, and ultrasonication procedures. These procedures form aerosols which can be inhaled by the patients, and consequently dentistry constitutes an area of specific concern for patient safety. In particular, older and immunocompromised patients are at risk of serious respiratory tract infections if the water contains pathogens such as Legionella pneumophila and Pseudomonas spp. In the EU it is recommended that the water in DUWLs should not exceed 200 colony-forming units (CFU) of heterotrophic bacteria (bacteria living on organic material) per milliliter of water to be acceptable in dental work. A number of efficient products are available on the market that can be applied onto dental units. New dental units are nowadays equipped with \"inbuilt\" systems. Such measures have resulted in an acceptable standard of water in 95% of the 1,200 dental units in the Public Dental Health Service of the Västra Götalands region of Sweden that were followed yearly for 4 years. For the majority of the remaining DUWLs with an unacceptable standard this is due to neglect or inappropriate routines for water-cleaning procedures. It is the ability to follow instructions rather than the cleaning procedure itself that is decisive if clinics and dental units are to have an appropriate standard of water in their systems.</p>","PeriodicalId":35771,"journal":{"name":"Monographs in Oral Science","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Biofilms in Dental Unit Water Lines.\",\"authors\":\"Gunnar Dahlen\",\"doi\":\"10.1159/000510195\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Biofilm formation has become a significant problem in dental unit water lines (DUWLs). The formation of biofilms and microbial growth in DUWLs leads to an unacceptably high number of microorganisms in the water used for spraying, cooling, and ultrasonication procedures. These procedures form aerosols which can be inhaled by the patients, and consequently dentistry constitutes an area of specific concern for patient safety. In particular, older and immunocompromised patients are at risk of serious respiratory tract infections if the water contains pathogens such as Legionella pneumophila and Pseudomonas spp. In the EU it is recommended that the water in DUWLs should not exceed 200 colony-forming units (CFU) of heterotrophic bacteria (bacteria living on organic material) per milliliter of water to be acceptable in dental work. A number of efficient products are available on the market that can be applied onto dental units. New dental units are nowadays equipped with \\\"inbuilt\\\" systems. Such measures have resulted in an acceptable standard of water in 95% of the 1,200 dental units in the Public Dental Health Service of the Västra Götalands region of Sweden that were followed yearly for 4 years. For the majority of the remaining DUWLs with an unacceptable standard this is due to neglect or inappropriate routines for water-cleaning procedures. It is the ability to follow instructions rather than the cleaning procedure itself that is decisive if clinics and dental units are to have an appropriate standard of water in their systems.</p>\",\"PeriodicalId\":35771,\"journal\":{\"name\":\"Monographs in Oral Science\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Monographs in Oral Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1159/000510195\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2020/12/21 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Monographs in Oral Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1159/000510195","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2020/12/21 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 6

摘要

生物膜的形成已成为牙科单位水管(duwl)中的一个重要问题。在duwl中,生物膜的形成和微生物的生长导致用于喷涂、冷却和超声波处理的水中微生物的数量高得令人无法接受。这些过程形成了可被患者吸入的气溶胶,因此牙科构成了一个特别关注患者安全的领域。特别是,如果水中含有嗜肺军团菌和假单胞菌等病原体,老年人和免疫功能低下的患者就有严重呼吸道感染的风险。在欧盟,建议DUWLs的水每毫升水中的异养细菌(生活在有机物质上的细菌)不应超过200个菌落形成单位(CFU),以供牙科工作接受。市场上有许多有效的产品可以应用于牙科单位。现在新的牙科单元都配备了“内置”系统。这些措施使瑞典Västra Götalands地区公共牙科保健服务的1 200个牙科单位中95%的水达到了可接受的标准,每年对这些单位进行4年的跟踪调查。对于其余大多数标准不能接受的duwl来说,这是由于忽视或不适当的水清洗程序。如果诊所和牙科单位要在其系统中拥有适当的水标准,则是遵循指示的能力而不是清洁程序本身起决定性作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Biofilms in Dental Unit Water Lines.

Biofilm formation has become a significant problem in dental unit water lines (DUWLs). The formation of biofilms and microbial growth in DUWLs leads to an unacceptably high number of microorganisms in the water used for spraying, cooling, and ultrasonication procedures. These procedures form aerosols which can be inhaled by the patients, and consequently dentistry constitutes an area of specific concern for patient safety. In particular, older and immunocompromised patients are at risk of serious respiratory tract infections if the water contains pathogens such as Legionella pneumophila and Pseudomonas spp. In the EU it is recommended that the water in DUWLs should not exceed 200 colony-forming units (CFU) of heterotrophic bacteria (bacteria living on organic material) per milliliter of water to be acceptable in dental work. A number of efficient products are available on the market that can be applied onto dental units. New dental units are nowadays equipped with "inbuilt" systems. Such measures have resulted in an acceptable standard of water in 95% of the 1,200 dental units in the Public Dental Health Service of the Västra Götalands region of Sweden that were followed yearly for 4 years. For the majority of the remaining DUWLs with an unacceptable standard this is due to neglect or inappropriate routines for water-cleaning procedures. It is the ability to follow instructions rather than the cleaning procedure itself that is decisive if clinics and dental units are to have an appropriate standard of water in their systems.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Monographs in Oral Science
Monographs in Oral Science Medicine-Medicine (all)
CiteScore
3.70
自引率
0.00%
发文量
21
期刊介绍: For two decades, ‘Monographs in Oral Science’ has provided a source of in-depth discussion of selected topics in the sciences related to stomatology. Senior investigators are invited to present expanded contributions in their fields of special expertise. The topics chosen are those which have generated a long-standing interest, and on which new conceptual insights or innovative biotechnology are making considerable impact. Authors are selected on the basis of having made lasting contributions to their chosen field and their willingness to share their findings with others.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信