Domen Vozel, Nejc Steiner, Nina Božanić Urbančič, Dejan Mladenov, Saba Battelino
{"title":"慢性中耳炎(COMQ-12)、眩晕(DHI、NVI)和 TINNITUS(THI)与健康相关的生活质量测量的斯洛文尼亚跨文化适应性和验证。","authors":"Domen Vozel, Nejc Steiner, Nina Božanić Urbančič, Dejan Mladenov, Saba Battelino","doi":"10.2478/sjph-2020-0016","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To provide physicians and patients with the tools needed to evaluate patients' problems and health-related quality of life by cross-culturally adapting and validating the Chronic Otitis Media Questionnaire 12 (COMQ-12), the Dizziness Handicap Inventory (DHI), the Neuropsychological Vertigo Inventory (NVI) and the Tinnitus Handicap Inventory (THI).</p><p><strong>Materials and methods: </strong>COMQ-12, DHI, NVI and THI were translated into the Slovenian language and completed by patients treated at our department for chronic otitis media, vertigo or tinnitus. The control group for each questionnaire consisted of healthy volunteers. Internal consistency, test-retest reliability, discriminant validity, diagnostic accuracy and cut-off value were determined for each questionnaire.</p><p><strong>Results: </strong>Test-retest reliability was excellent for DHI (ICC A=0.946) and NVI (p=0.315, ICC A=0.975), good to excellent for COMQ-12 (p=0.680, ICC A=0.858) and satisfactory for THI (p=0.120). Discriminant validity was confirmed for each questionnaire (p>0.05) using the Mann-Whitney U test (COMQ-12, DHI, THI) or the Welch t-test (NVI). COMQ-12 had acceptable (α=0.796) and DHI (α=0.910), NVI (α=0.950) and THI (α=0.924) perfect internal consistency. COMQ-12 and DHI had excellent, NVI acceptable and THI perfect diagnostic accuracy (AUC=0.987, AUC=0.999, AUC=0.781 and AUC=1.000 respectively). Cut-off values determined by Youden's index were 7, 7, 9 and 56 for COMQ-12, THI, DHI and NVI, respectively.</p><p><strong>Conclusion: </strong>Slovenian COMQ-12, DHI, NVI and THI are a valid and accurate tool for the diagnosis and measurement of health-related quality of life in patients with chronic otitis media, vertigo and tinnitus. They could aid general practitioners, occupational health specialists, neurologists and otorhinolaryngologists.</p>","PeriodicalId":45127,"journal":{"name":"Zdravstveno Varstvo","volume":"59 3","pages":"120-127"},"PeriodicalIF":1.6000,"publicationDate":"2020-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/2a/2d/sjph-59-120.PMC7478096.pdf","citationCount":"0","resultStr":"{\"title\":\"Slovenian Cross-Cultural Adaptation and Validation of Health-Related Quality of Life Measures for Chronic Otitis Media (COMQ-12), Vertigo (DHI, NVI) and TINNITUS (THI).\",\"authors\":\"Domen Vozel, Nejc Steiner, Nina Božanić Urbančič, Dejan Mladenov, Saba Battelino\",\"doi\":\"10.2478/sjph-2020-0016\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To provide physicians and patients with the tools needed to evaluate patients' problems and health-related quality of life by cross-culturally adapting and validating the Chronic Otitis Media Questionnaire 12 (COMQ-12), the Dizziness Handicap Inventory (DHI), the Neuropsychological Vertigo Inventory (NVI) and the Tinnitus Handicap Inventory (THI).</p><p><strong>Materials and methods: </strong>COMQ-12, DHI, NVI and THI were translated into the Slovenian language and completed by patients treated at our department for chronic otitis media, vertigo or tinnitus. The control group for each questionnaire consisted of healthy volunteers. Internal consistency, test-retest reliability, discriminant validity, diagnostic accuracy and cut-off value were determined for each questionnaire.</p><p><strong>Results: </strong>Test-retest reliability was excellent for DHI (ICC A=0.946) and NVI (p=0.315, ICC A=0.975), good to excellent for COMQ-12 (p=0.680, ICC A=0.858) and satisfactory for THI (p=0.120). Discriminant validity was confirmed for each questionnaire (p>0.05) using the Mann-Whitney U test (COMQ-12, DHI, THI) or the Welch t-test (NVI). COMQ-12 had acceptable (α=0.796) and DHI (α=0.910), NVI (α=0.950) and THI (α=0.924) perfect internal consistency. COMQ-12 and DHI had excellent, NVI acceptable and THI perfect diagnostic accuracy (AUC=0.987, AUC=0.999, AUC=0.781 and AUC=1.000 respectively). Cut-off values determined by Youden's index were 7, 7, 9 and 56 for COMQ-12, THI, DHI and NVI, respectively.</p><p><strong>Conclusion: </strong>Slovenian COMQ-12, DHI, NVI and THI are a valid and accurate tool for the diagnosis and measurement of health-related quality of life in patients with chronic otitis media, vertigo and tinnitus. They could aid general practitioners, occupational health specialists, neurologists and otorhinolaryngologists.</p>\",\"PeriodicalId\":45127,\"journal\":{\"name\":\"Zdravstveno Varstvo\",\"volume\":\"59 3\",\"pages\":\"120-127\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2020-06-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/2a/2d/sjph-59-120.PMC7478096.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Zdravstveno Varstvo\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2478/sjph-2020-0016\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2020/9/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zdravstveno Varstvo","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2478/sjph-2020-0016","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2020/9/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH","Score":null,"Total":0}
Slovenian Cross-Cultural Adaptation and Validation of Health-Related Quality of Life Measures for Chronic Otitis Media (COMQ-12), Vertigo (DHI, NVI) and TINNITUS (THI).
Purpose: To provide physicians and patients with the tools needed to evaluate patients' problems and health-related quality of life by cross-culturally adapting and validating the Chronic Otitis Media Questionnaire 12 (COMQ-12), the Dizziness Handicap Inventory (DHI), the Neuropsychological Vertigo Inventory (NVI) and the Tinnitus Handicap Inventory (THI).
Materials and methods: COMQ-12, DHI, NVI and THI were translated into the Slovenian language and completed by patients treated at our department for chronic otitis media, vertigo or tinnitus. The control group for each questionnaire consisted of healthy volunteers. Internal consistency, test-retest reliability, discriminant validity, diagnostic accuracy and cut-off value were determined for each questionnaire.
Results: Test-retest reliability was excellent for DHI (ICC A=0.946) and NVI (p=0.315, ICC A=0.975), good to excellent for COMQ-12 (p=0.680, ICC A=0.858) and satisfactory for THI (p=0.120). Discriminant validity was confirmed for each questionnaire (p>0.05) using the Mann-Whitney U test (COMQ-12, DHI, THI) or the Welch t-test (NVI). COMQ-12 had acceptable (α=0.796) and DHI (α=0.910), NVI (α=0.950) and THI (α=0.924) perfect internal consistency. COMQ-12 and DHI had excellent, NVI acceptable and THI perfect diagnostic accuracy (AUC=0.987, AUC=0.999, AUC=0.781 and AUC=1.000 respectively). Cut-off values determined by Youden's index were 7, 7, 9 and 56 for COMQ-12, THI, DHI and NVI, respectively.
Conclusion: Slovenian COMQ-12, DHI, NVI and THI are a valid and accurate tool for the diagnosis and measurement of health-related quality of life in patients with chronic otitis media, vertigo and tinnitus. They could aid general practitioners, occupational health specialists, neurologists and otorhinolaryngologists.