Gemma Serrano-Heras, Inmaculada Díaz-Maroto, Beatriz Castro-Robles, Blanca Carrión, Ana B Perona-Moratalla, Julia Gracia, Sandra Arteaga, Francisco Hernández-Fernández, Jorge García-García, Oscar Ayo-Martín, Tomás Segura
{"title":"血凋亡小体的分离和定量——一种评估缺血性卒中和神经退行性疾病患者细胞凋亡的无创工具","authors":"Gemma Serrano-Heras, Inmaculada Díaz-Maroto, Beatriz Castro-Robles, Blanca Carrión, Ana B Perona-Moratalla, Julia Gracia, Sandra Arteaga, Francisco Hernández-Fernández, Jorge García-García, Oscar Ayo-Martín, Tomás Segura","doi":"10.1186/s12575-020-00130-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Improper regulation of apoptosis has been postulated as one of the main factors that contributes to the etiology and/or progression of several prevalent diseases, including ischemic stroke and neurodegenerative pathologies. Consequently, in the last few years, there has been an ever-growing interest in the in vivo study of apoptosis. The clinical application of the tissue sampling and imaging approaches to analyze apoptosis in neurological diseases is, however, limited. Since apoptotic bodies are membrane vesicles that are released from fragmented apoptotic cells, it follows that the presence of these vesicles in the bloodstream is likely due to the apoptotic death of cells in tissues. We therefore propose to use circulating apoptotic bodies as biomarkers for measuring apoptotic death in patients with ischemic stroke and neurodegenerative diseases.</p><p><strong>Results: </strong>Since there is no scientific literature establishing the most appropriate method for collecting and enumerating apoptotic bodies from human blood samples. Authors, here, describe a reproducible centrifugation-based method combined with flow cytometry analysis to isolate and quantify plasma apoptotic bodies of patients with ischemic stroke, multiple sclerosis, Parkinson's disease and also in healthy controls. Electron microscopy, dynamic light scattering and proteomic characterization in combination with flow cytometry studies revealed that our isolation method achieves notable recovery rates of highly-purified intact apoptotic bodies.</p><p><strong>Conclusions: </strong>This easy, minimally time consuming and effective procedure for isolating and quantifying plasma apoptotic bodies could help physicians to implement the use of such vesicles as a non-invasive tool to monitor apoptosis in patients with cerebrovascular and neurodegenerative diseases for prognostic purposes and for monitoring disease activity.</p>","PeriodicalId":8960,"journal":{"name":"Biological Procedures Online","volume":"22 ","pages":"17"},"PeriodicalIF":3.7000,"publicationDate":"2020-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1186/s12575-020-00130-8","citationCount":"20","resultStr":"{\"title\":\"Isolation and Quantification of Blood Apoptotic Bodies, a Non-invasive Tool to Evaluate Apoptosis in Patients with Ischemic Stroke and Neurodegenerative Diseases.\",\"authors\":\"Gemma Serrano-Heras, Inmaculada Díaz-Maroto, Beatriz Castro-Robles, Blanca Carrión, Ana B Perona-Moratalla, Julia Gracia, Sandra Arteaga, Francisco Hernández-Fernández, Jorge García-García, Oscar Ayo-Martín, Tomás Segura\",\"doi\":\"10.1186/s12575-020-00130-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Improper regulation of apoptosis has been postulated as one of the main factors that contributes to the etiology and/or progression of several prevalent diseases, including ischemic stroke and neurodegenerative pathologies. Consequently, in the last few years, there has been an ever-growing interest in the in vivo study of apoptosis. The clinical application of the tissue sampling and imaging approaches to analyze apoptosis in neurological diseases is, however, limited. Since apoptotic bodies are membrane vesicles that are released from fragmented apoptotic cells, it follows that the presence of these vesicles in the bloodstream is likely due to the apoptotic death of cells in tissues. We therefore propose to use circulating apoptotic bodies as biomarkers for measuring apoptotic death in patients with ischemic stroke and neurodegenerative diseases.</p><p><strong>Results: </strong>Since there is no scientific literature establishing the most appropriate method for collecting and enumerating apoptotic bodies from human blood samples. Authors, here, describe a reproducible centrifugation-based method combined with flow cytometry analysis to isolate and quantify plasma apoptotic bodies of patients with ischemic stroke, multiple sclerosis, Parkinson's disease and also in healthy controls. Electron microscopy, dynamic light scattering and proteomic characterization in combination with flow cytometry studies revealed that our isolation method achieves notable recovery rates of highly-purified intact apoptotic bodies.</p><p><strong>Conclusions: </strong>This easy, minimally time consuming and effective procedure for isolating and quantifying plasma apoptotic bodies could help physicians to implement the use of such vesicles as a non-invasive tool to monitor apoptosis in patients with cerebrovascular and neurodegenerative diseases for prognostic purposes and for monitoring disease activity.</p>\",\"PeriodicalId\":8960,\"journal\":{\"name\":\"Biological Procedures Online\",\"volume\":\"22 \",\"pages\":\"17\"},\"PeriodicalIF\":3.7000,\"publicationDate\":\"2020-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1186/s12575-020-00130-8\",\"citationCount\":\"20\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biological Procedures Online\",\"FirstCategoryId\":\"99\",\"ListUrlMain\":\"https://doi.org/10.1186/s12575-020-00130-8\",\"RegionNum\":3,\"RegionCategory\":\"生物学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2020/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q1\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biological Procedures Online","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.1186/s12575-020-00130-8","RegionNum":3,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2020/1/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
Isolation and Quantification of Blood Apoptotic Bodies, a Non-invasive Tool to Evaluate Apoptosis in Patients with Ischemic Stroke and Neurodegenerative Diseases.
Background: Improper regulation of apoptosis has been postulated as one of the main factors that contributes to the etiology and/or progression of several prevalent diseases, including ischemic stroke and neurodegenerative pathologies. Consequently, in the last few years, there has been an ever-growing interest in the in vivo study of apoptosis. The clinical application of the tissue sampling and imaging approaches to analyze apoptosis in neurological diseases is, however, limited. Since apoptotic bodies are membrane vesicles that are released from fragmented apoptotic cells, it follows that the presence of these vesicles in the bloodstream is likely due to the apoptotic death of cells in tissues. We therefore propose to use circulating apoptotic bodies as biomarkers for measuring apoptotic death in patients with ischemic stroke and neurodegenerative diseases.
Results: Since there is no scientific literature establishing the most appropriate method for collecting and enumerating apoptotic bodies from human blood samples. Authors, here, describe a reproducible centrifugation-based method combined with flow cytometry analysis to isolate and quantify plasma apoptotic bodies of patients with ischemic stroke, multiple sclerosis, Parkinson's disease and also in healthy controls. Electron microscopy, dynamic light scattering and proteomic characterization in combination with flow cytometry studies revealed that our isolation method achieves notable recovery rates of highly-purified intact apoptotic bodies.
Conclusions: This easy, minimally time consuming and effective procedure for isolating and quantifying plasma apoptotic bodies could help physicians to implement the use of such vesicles as a non-invasive tool to monitor apoptosis in patients with cerebrovascular and neurodegenerative diseases for prognostic purposes and for monitoring disease activity.
期刊介绍:
iological Procedures Online publishes articles that improve access to techniques and methods in the medical and biological sciences.
We are also interested in short but important research discoveries, such as new animal disease models.
Topics of interest include, but are not limited to:
Reports of new research techniques and applications of existing techniques
Technical analyses of research techniques and published reports
Validity analyses of research methods and approaches to judging the validity of research reports
Application of common research methods
Reviews of existing techniques
Novel/important product information
Biological Procedures Online places emphasis on multidisciplinary approaches that integrate methodologies from medicine, biology, chemistry, imaging, engineering, bioinformatics, computer science, and systems analysis.