截尾对复合材料粘结强度统计评价的影响。

IF 2.5 3区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Lukas Comba, Antonin Tichy, Pavel Bradna
{"title":"截尾对复合材料粘结强度统计评价的影响。","authors":"Lukas Comba,&nbsp;Antonin Tichy,&nbsp;Pavel Bradna","doi":"10.3290/j.jad.a44283","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To determine the effect of Weibull analysis with censoring of cohesive failures on the evaluation of the effect of surface treatment and adhesive on the microtensile composite-composite bond strength.</p><p><strong>Materials and methods: </strong>Surfaces of Filtek Z250 (3M Oral Care) specimens aged in distilled water for five months at 37°C were ground with SiC paper P320 or air abraded with Al2O3 and built up with the same composite using Optibond FL (OPF, Kerr), Clearfil SE Bond (CSE, Kuraray Noritake) and Gluma Comfort Bond (GLU, Kulzer) adhesives. After sectioning and trimming, the specimens were stored at 37°C in distilled water for 24 h and then tested in a microtensile bond strength setup. Complete datasets of all strength data and adhesive datasets containing adhesively failed specimens were analyzed with a one-way Welch ANOVA at α = 0.05 and compared with the results of Weibull analysis applied on complete and adhesive datasets as well as complete datasets right censored for cohesive failures. Weibull shape (m) and scale (σo) parameters were estimated using the maximum likelihood method and used to calculate bond strength (σ0.10) at 10% probability of failure as a measure of system performance. The surface morphology was studied using light and scanning electron microscopy.</p><p><strong>Results: </strong>While ANOVA indicated a significant effect of surface treatment and non-significant effect of the adhesive, the Weibull analysis results depended on bond strength characteristics and censoring. The scale parameter of the complete dataset indicating a significant effect of surface treatment for all adhesives became statistically non-significant for CSE after censoring. When this effect was evaluated by σ0.10, the non-significant effect of surface treatment for OPF and GLU became statistically significant due to censoring. The effect of the adhesive evaluated by the scale parameter was non-significant both for surfaces as well as complete and censored datasets. On the other hand, s0.10 suggested significant differences between adhesives on the ground surface for complete datasets which became statistically non-significant for the censored datasets.</p><p><strong>Conclusion: </strong>This study indicates that the results of statistical evaluation of bond strength can be affected not only by the experimental set-up and statistical model but also the bond strength characteristics and the manner in which the strengths of cohesively failed specimens are included in calculations.</p>","PeriodicalId":55604,"journal":{"name":"Journal of Adhesive Dentistry","volume":"22 2","pages":"183-193"},"PeriodicalIF":2.5000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"The Effect of Censoring on the Statistical Evaluation of Composite-to-Composite Bond Strength.\",\"authors\":\"Lukas Comba,&nbsp;Antonin Tichy,&nbsp;Pavel Bradna\",\"doi\":\"10.3290/j.jad.a44283\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To determine the effect of Weibull analysis with censoring of cohesive failures on the evaluation of the effect of surface treatment and adhesive on the microtensile composite-composite bond strength.</p><p><strong>Materials and methods: </strong>Surfaces of Filtek Z250 (3M Oral Care) specimens aged in distilled water for five months at 37°C were ground with SiC paper P320 or air abraded with Al2O3 and built up with the same composite using Optibond FL (OPF, Kerr), Clearfil SE Bond (CSE, Kuraray Noritake) and Gluma Comfort Bond (GLU, Kulzer) adhesives. After sectioning and trimming, the specimens were stored at 37°C in distilled water for 24 h and then tested in a microtensile bond strength setup. Complete datasets of all strength data and adhesive datasets containing adhesively failed specimens were analyzed with a one-way Welch ANOVA at α = 0.05 and compared with the results of Weibull analysis applied on complete and adhesive datasets as well as complete datasets right censored for cohesive failures. Weibull shape (m) and scale (σo) parameters were estimated using the maximum likelihood method and used to calculate bond strength (σ0.10) at 10% probability of failure as a measure of system performance. The surface morphology was studied using light and scanning electron microscopy.</p><p><strong>Results: </strong>While ANOVA indicated a significant effect of surface treatment and non-significant effect of the adhesive, the Weibull analysis results depended on bond strength characteristics and censoring. The scale parameter of the complete dataset indicating a significant effect of surface treatment for all adhesives became statistically non-significant for CSE after censoring. When this effect was evaluated by σ0.10, the non-significant effect of surface treatment for OPF and GLU became statistically significant due to censoring. The effect of the adhesive evaluated by the scale parameter was non-significant both for surfaces as well as complete and censored datasets. On the other hand, s0.10 suggested significant differences between adhesives on the ground surface for complete datasets which became statistically non-significant for the censored datasets.</p><p><strong>Conclusion: </strong>This study indicates that the results of statistical evaluation of bond strength can be affected not only by the experimental set-up and statistical model but also the bond strength characteristics and the manner in which the strengths of cohesively failed specimens are included in calculations.</p>\",\"PeriodicalId\":55604,\"journal\":{\"name\":\"Journal of Adhesive Dentistry\",\"volume\":\"22 2\",\"pages\":\"183-193\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2020-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Adhesive Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3290/j.jad.a44283\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Adhesive Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3290/j.jad.a44283","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 6

摘要

目的:利用威布尔分析对粘接失效进行修正,评价表面处理和胶粘剂对微拉伸复合材料粘接强度的影响。材料和方法:Filtek Z250 (3M Oral Care)样品在37°C蒸蒸水中陈化5个月,表面用SiC纸P320或Al2O3空气研磨,并使用Optibond FL (OPF, Kerr), Clearfil SE Bond (CSE, Kuraray Noritake)和Gluma Comfort Bond (GLU, Kulzer)粘合剂建立相同的复合材料。切片、修整后,在37℃蒸馏水中保存24 h,然后在微拉伸粘结强度设置中进行测试。使用单向Welch方差分析(α = 0.05)对所有强度数据的完整数据集和包含粘合失效样品的粘合剂数据集进行分析,并与应用于完整数据集和粘合剂数据集的Weibull分析结果以及对粘合失效进行审查的完整数据集进行比较。使用最大似然法估计威布尔形状(m)和尺度(σo)参数,并用于计算10%失效概率下的粘结强度(σ0.10),作为系统性能的度量。利用光镜和扫描电镜对其表面形貌进行了研究。结果:方差分析显示表面处理的影响显著,而粘接剂的影响不显著,Weibull分析结果取决于粘合强度特征和删节。完整数据集的尺度参数表明,表面处理对所有粘合剂的显著影响,在审查后,CSE在统计上不显著。当用σ0.10评价这一效应时,表面处理对OPF和GLU的不显著影响由于剔除而变得具有统计学意义。通过尺度参数评估的粘合剂的影响对于表面以及完整和删除的数据集都是不显著的。另一方面,s0.10表明完整数据集的地面粘合剂之间存在显著差异,而对于删除数据集,这在统计上不显著。结论:黏结强度统计评价的结果不仅受试验设置和统计模型的影响,还受黏结强度特性和计算黏结破坏试件强度的方式的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Effect of Censoring on the Statistical Evaluation of Composite-to-Composite Bond Strength.

Purpose: To determine the effect of Weibull analysis with censoring of cohesive failures on the evaluation of the effect of surface treatment and adhesive on the microtensile composite-composite bond strength.

Materials and methods: Surfaces of Filtek Z250 (3M Oral Care) specimens aged in distilled water for five months at 37°C were ground with SiC paper P320 or air abraded with Al2O3 and built up with the same composite using Optibond FL (OPF, Kerr), Clearfil SE Bond (CSE, Kuraray Noritake) and Gluma Comfort Bond (GLU, Kulzer) adhesives. After sectioning and trimming, the specimens were stored at 37°C in distilled water for 24 h and then tested in a microtensile bond strength setup. Complete datasets of all strength data and adhesive datasets containing adhesively failed specimens were analyzed with a one-way Welch ANOVA at α = 0.05 and compared with the results of Weibull analysis applied on complete and adhesive datasets as well as complete datasets right censored for cohesive failures. Weibull shape (m) and scale (σo) parameters were estimated using the maximum likelihood method and used to calculate bond strength (σ0.10) at 10% probability of failure as a measure of system performance. The surface morphology was studied using light and scanning electron microscopy.

Results: While ANOVA indicated a significant effect of surface treatment and non-significant effect of the adhesive, the Weibull analysis results depended on bond strength characteristics and censoring. The scale parameter of the complete dataset indicating a significant effect of surface treatment for all adhesives became statistically non-significant for CSE after censoring. When this effect was evaluated by σ0.10, the non-significant effect of surface treatment for OPF and GLU became statistically significant due to censoring. The effect of the adhesive evaluated by the scale parameter was non-significant both for surfaces as well as complete and censored datasets. On the other hand, s0.10 suggested significant differences between adhesives on the ground surface for complete datasets which became statistically non-significant for the censored datasets.

Conclusion: This study indicates that the results of statistical evaluation of bond strength can be affected not only by the experimental set-up and statistical model but also the bond strength characteristics and the manner in which the strengths of cohesively failed specimens are included in calculations.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Adhesive Dentistry
Journal of Adhesive Dentistry 医学-牙科与口腔外科
CiteScore
5.20
自引率
6.10%
发文量
44
审稿时长
6-12 weeks
期刊介绍: New materials and applications for adhesion are profoundly changing the way dentistry is delivered. Bonding techniques, which have long been restricted to the tooth hard tissues, enamel, and dentin, have obvious applications in operative and preventive dentistry, as well as in esthetic and pediatric dentistry, prosthodontics, and orthodontics. The current development of adhesive techniques for soft tissues and slow-releasing agents will expand applications to include periodontics and oral surgery. Scientifically sound, peer-reviewed articles explore the latest innovations in these emerging fields.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信