Gloria D'alessandro, Maurizio Leone, Jacopo Antolini, Simone Ferrero, Paolo Sala, Guglielmo Melloni, Giuseppe Fasolis, Claudio Gustavino
{"title":"Altis®单切口吊带治疗尿压力性失禁患者的三年随访。","authors":"Gloria D'alessandro, Maurizio Leone, Jacopo Antolini, Simone Ferrero, Paolo Sala, Guglielmo Melloni, Giuseppe Fasolis, Claudio Gustavino","doi":"10.23736/S0026-4784.20.04496-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The purpose of the study is to report three years follow-up of single incision slings for the treatment of stress urinary incontinence (SUI). The main outcomes are to evaluate the efficacy of the device and to assess safety, adverse events, quality of life, demographic features of treated women and prognostic factors for SUI.</p><p><strong>Methods: </strong>We performed a retrospective, double-center, single-arm study. Data were collected by medical records and a telephone interview 3 years after the implant of the mini-sling. Complication rate, subjective efficacy and degree of satisfaction were investigated.</p><p><strong>Results: </strong>Fifty-four patients were treated between March 2015 and March 2017, of which 47 answered the survey. Forty-one of 47 procedures (87.2%) were considered effective. Among more relevant complications, there was one case of extrusion of mesh and three cases of new onset of urinary disfunction, of which two cases of urgency urinary incontinence (UUI) and one case of de-novo SUI. Most complications were solved within few days after the procedure. Concerning the subjective impression of improvement, investigated by using the Patient Global Impression of Improvement (PGI-I) questionnaires, 41 patients reported subjective satisfaction, three reported no change in quality of life and three patients had worsening of symptoms.</p><p><strong>Conclusions: </strong>The procedure was safe and effective for the treatment of SUI but more data are needed to confirm our preliminary results.</p>","PeriodicalId":18745,"journal":{"name":"Minerva ginecologica","volume":"72 1","pages":"12-18"},"PeriodicalIF":1.0000,"publicationDate":"2020-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Three-year follow-up in patients with urinary stress incontinence treated with Altis® single-incision sling.\",\"authors\":\"Gloria D'alessandro, Maurizio Leone, Jacopo Antolini, Simone Ferrero, Paolo Sala, Guglielmo Melloni, Giuseppe Fasolis, Claudio Gustavino\",\"doi\":\"10.23736/S0026-4784.20.04496-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The purpose of the study is to report three years follow-up of single incision slings for the treatment of stress urinary incontinence (SUI). The main outcomes are to evaluate the efficacy of the device and to assess safety, adverse events, quality of life, demographic features of treated women and prognostic factors for SUI.</p><p><strong>Methods: </strong>We performed a retrospective, double-center, single-arm study. Data were collected by medical records and a telephone interview 3 years after the implant of the mini-sling. Complication rate, subjective efficacy and degree of satisfaction were investigated.</p><p><strong>Results: </strong>Fifty-four patients were treated between March 2015 and March 2017, of which 47 answered the survey. Forty-one of 47 procedures (87.2%) were considered effective. Among more relevant complications, there was one case of extrusion of mesh and three cases of new onset of urinary disfunction, of which two cases of urgency urinary incontinence (UUI) and one case of de-novo SUI. Most complications were solved within few days after the procedure. Concerning the subjective impression of improvement, investigated by using the Patient Global Impression of Improvement (PGI-I) questionnaires, 41 patients reported subjective satisfaction, three reported no change in quality of life and three patients had worsening of symptoms.</p><p><strong>Conclusions: </strong>The procedure was safe and effective for the treatment of SUI but more data are needed to confirm our preliminary results.</p>\",\"PeriodicalId\":18745,\"journal\":{\"name\":\"Minerva ginecologica\",\"volume\":\"72 1\",\"pages\":\"12-18\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2020-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Minerva ginecologica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23736/S0026-4784.20.04496-2\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Minerva ginecologica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23736/S0026-4784.20.04496-2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
Three-year follow-up in patients with urinary stress incontinence treated with Altis® single-incision sling.
Background: The purpose of the study is to report three years follow-up of single incision slings for the treatment of stress urinary incontinence (SUI). The main outcomes are to evaluate the efficacy of the device and to assess safety, adverse events, quality of life, demographic features of treated women and prognostic factors for SUI.
Methods: We performed a retrospective, double-center, single-arm study. Data were collected by medical records and a telephone interview 3 years after the implant of the mini-sling. Complication rate, subjective efficacy and degree of satisfaction were investigated.
Results: Fifty-four patients were treated between March 2015 and March 2017, of which 47 answered the survey. Forty-one of 47 procedures (87.2%) were considered effective. Among more relevant complications, there was one case of extrusion of mesh and three cases of new onset of urinary disfunction, of which two cases of urgency urinary incontinence (UUI) and one case of de-novo SUI. Most complications were solved within few days after the procedure. Concerning the subjective impression of improvement, investigated by using the Patient Global Impression of Improvement (PGI-I) questionnaires, 41 patients reported subjective satisfaction, three reported no change in quality of life and three patients had worsening of symptoms.
Conclusions: The procedure was safe and effective for the treatment of SUI but more data are needed to confirm our preliminary results.
期刊介绍:
The journal Minerva Ginecologica publishes scientific papers on obstetrics and gynecology. Manuscripts may be submitted in the form of editorials, original articles, review articles, case reports, therapeutical notes, special articles and letters to the Editor. Manuscripts are expected to comply with the instructions to authors which conform to the Uniform Requirements for Manuscripts Submitted to Biomedical Editors by the International Committee of Medical Journal Editors (www.icmje.org). Articles not conforming to international standards will not be considered for acceptance.