{"title":"双重危险:抢救血管成形术中支架球囊放气失败。","authors":"Rutvik Trivedi","doi":"10.1556/1646.11.2019.16","DOIUrl":null,"url":null,"abstract":"<p><p>Failure to deflate the angioplasty balloon following its inflation during percutaneous coronary intervention (PCI) is an unusual complication. We report a case of an undeflatable stent balloon in a 70-year-old male, who underwent PCI for the right coronary artery after failed thrombolysis with streptokinase. After many failed attempts, the patient was cautiously managed by controlled puncture with a stiff guide wire. The procedure was successful without any hemodynamic compromise and ventricular tachycardia.</p>","PeriodicalId":45181,"journal":{"name":"Interventional Medicine and Applied Science","volume":"11 2","pages":"128-130"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1556/1646.11.2019.16","citationCount":"3","resultStr":"{\"title\":\"Double jeopardy: Failure to deflate stent balloon in rescue angioplasty.\",\"authors\":\"Rutvik Trivedi\",\"doi\":\"10.1556/1646.11.2019.16\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Failure to deflate the angioplasty balloon following its inflation during percutaneous coronary intervention (PCI) is an unusual complication. We report a case of an undeflatable stent balloon in a 70-year-old male, who underwent PCI for the right coronary artery after failed thrombolysis with streptokinase. After many failed attempts, the patient was cautiously managed by controlled puncture with a stiff guide wire. The procedure was successful without any hemodynamic compromise and ventricular tachycardia.</p>\",\"PeriodicalId\":45181,\"journal\":{\"name\":\"Interventional Medicine and Applied Science\",\"volume\":\"11 2\",\"pages\":\"128-130\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1556/1646.11.2019.16\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Interventional Medicine and Applied Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1556/1646.11.2019.16\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional Medicine and Applied Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1556/1646.11.2019.16","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
Double jeopardy: Failure to deflate stent balloon in rescue angioplasty.
Failure to deflate the angioplasty balloon following its inflation during percutaneous coronary intervention (PCI) is an unusual complication. We report a case of an undeflatable stent balloon in a 70-year-old male, who underwent PCI for the right coronary artery after failed thrombolysis with streptokinase. After many failed attempts, the patient was cautiously managed by controlled puncture with a stiff guide wire. The procedure was successful without any hemodynamic compromise and ventricular tachycardia.