Daniel D Lewis, Stanley E Kim, Justin Shmalberg, Sandra L MacArthur
{"title":"使用铰链圆形固定架和牵张成骨术矫正幼年犬胫骨平台角度过大和肢体缩短。","authors":"Daniel D Lewis, Stanley E Kim, Justin Shmalberg, Sandra L MacArthur","doi":"10.1155/2019/1439237","DOIUrl":null,"url":null,"abstract":"<p><p>An 18-week-old Rhodesian Ridgeback puppy that was hit by a car sustained a Salter-Harris type III fracture of the left proximal tibial physis and ipsilateral diaphyseal femoral and tibial fractures. The diaphyseal fractures were successfully stabilized with bone plate fixation. Premature closure of the caudal aspect of the proximal tibial physis, secondary to the proximal physeal fracture, resulted in an excessively high tibial plateau angle (TPA) of 50° with a limb length discrepancy of 13% by 24 weeks of age. The deformity was addressed by performing a proximal tibial osteotomy and subsequent distraction osteogenesis to reduce the TPA while concurrently lengthening the crus. A radial osteotomy was performed in the proximal metaphyseal region and the hinged fixator was applied. Distraction was initiated the day following surgery at a rate of 1 mm per day as measured along the caudal cortex of the tibia with a rhythm of three distractions daily. Distraction was terminated 19 days postoperatively. Sequential distraction of the osteotomy resulted in 17 mm of tibial lengthening and a final TPA of 3°. The fixator was removed 52 days after application. Complications included wire tract inflammation involving the wires securing the proximal segment and a calcaneal fracture which required bone plate stabilization. The left pelvic limb was only 8% shorter than the right pelvic limb and the dog had only a subtle lameness 12 months after surgery. The hinged circular fixator construct allowed for both the reduction of the TPA and limb segment lengthening in this dog.</p>","PeriodicalId":37339,"journal":{"name":"Case Reports in Veterinary Medicine","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-11-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2019/1439237","citationCount":"1","resultStr":"{\"title\":\"Correction of Excessive Tibial Plateau Angle and Limb Shortening in a Juvenile Dog Using a Hinged Circular Fixator Construct and Distraction Osteogenesis.\",\"authors\":\"Daniel D Lewis, Stanley E Kim, Justin Shmalberg, Sandra L MacArthur\",\"doi\":\"10.1155/2019/1439237\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>An 18-week-old Rhodesian Ridgeback puppy that was hit by a car sustained a Salter-Harris type III fracture of the left proximal tibial physis and ipsilateral diaphyseal femoral and tibial fractures. The diaphyseal fractures were successfully stabilized with bone plate fixation. Premature closure of the caudal aspect of the proximal tibial physis, secondary to the proximal physeal fracture, resulted in an excessively high tibial plateau angle (TPA) of 50° with a limb length discrepancy of 13% by 24 weeks of age. The deformity was addressed by performing a proximal tibial osteotomy and subsequent distraction osteogenesis to reduce the TPA while concurrently lengthening the crus. A radial osteotomy was performed in the proximal metaphyseal region and the hinged fixator was applied. Distraction was initiated the day following surgery at a rate of 1 mm per day as measured along the caudal cortex of the tibia with a rhythm of three distractions daily. Distraction was terminated 19 days postoperatively. Sequential distraction of the osteotomy resulted in 17 mm of tibial lengthening and a final TPA of 3°. The fixator was removed 52 days after application. Complications included wire tract inflammation involving the wires securing the proximal segment and a calcaneal fracture which required bone plate stabilization. The left pelvic limb was only 8% shorter than the right pelvic limb and the dog had only a subtle lameness 12 months after surgery. The hinged circular fixator construct allowed for both the reduction of the TPA and limb segment lengthening in this dog.</p>\",\"PeriodicalId\":37339,\"journal\":{\"name\":\"Case Reports in Veterinary Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-11-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1155/2019/1439237\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Case Reports in Veterinary Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2019/1439237\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2019/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"Veterinary\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Case Reports in Veterinary Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2019/1439237","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2019/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"Veterinary","Score":null,"Total":0}
Correction of Excessive Tibial Plateau Angle and Limb Shortening in a Juvenile Dog Using a Hinged Circular Fixator Construct and Distraction Osteogenesis.
An 18-week-old Rhodesian Ridgeback puppy that was hit by a car sustained a Salter-Harris type III fracture of the left proximal tibial physis and ipsilateral diaphyseal femoral and tibial fractures. The diaphyseal fractures were successfully stabilized with bone plate fixation. Premature closure of the caudal aspect of the proximal tibial physis, secondary to the proximal physeal fracture, resulted in an excessively high tibial plateau angle (TPA) of 50° with a limb length discrepancy of 13% by 24 weeks of age. The deformity was addressed by performing a proximal tibial osteotomy and subsequent distraction osteogenesis to reduce the TPA while concurrently lengthening the crus. A radial osteotomy was performed in the proximal metaphyseal region and the hinged fixator was applied. Distraction was initiated the day following surgery at a rate of 1 mm per day as measured along the caudal cortex of the tibia with a rhythm of three distractions daily. Distraction was terminated 19 days postoperatively. Sequential distraction of the osteotomy resulted in 17 mm of tibial lengthening and a final TPA of 3°. The fixator was removed 52 days after application. Complications included wire tract inflammation involving the wires securing the proximal segment and a calcaneal fracture which required bone plate stabilization. The left pelvic limb was only 8% shorter than the right pelvic limb and the dog had only a subtle lameness 12 months after surgery. The hinged circular fixator construct allowed for both the reduction of the TPA and limb segment lengthening in this dog.
期刊介绍:
Case Reports in Veterinary Medicine is a peer-reviewed, Open Access journal that publishes case reports and case series in all areas of veterinary medicine.