烧伤导致心脏起搏器外露的处理。

Q2 Medicine
Christopher William Maxwell, Joshua Carson, Michael R Kaufmann, Brenda G Fahy
{"title":"烧伤导致心脏起搏器外露的处理。","authors":"Christopher William Maxwell,&nbsp;Joshua Carson,&nbsp;Michael R Kaufmann,&nbsp;Brenda G Fahy","doi":"10.2478/rjaic-2019-0012","DOIUrl":null,"url":null,"abstract":"<p><p>Annual implants of cardiovascular implantable devices (CIEDs) are increasing, thus increasing the risk of device exposure. This case presents CIED management issues following traumatic thermal injury. A 59-year-old female presented to intensive care with 42% total body surface area burn involving tissue over her pacemaker generator. Electrophysiologists interrogated and reprogrammed the pacer and observed the patient over 72 hours without pacing. Serratia bacteremia developed and cardiology recommended device removal. The pacemaker generator and leads were removed by cardiothoracic and burn surgery. Postoperatively, asystole required emergency transvenous pacing wire placement. During bacteremia treatment, cardiology planned to pace with an active-fixation screw-in lead with long-term plans to place a single right ventricular chamber leadless pacemaker because of the extensive burns. The patient developed fungemia and the family opted for comfort care. This case report discusses the management of a CIED exposed after a traumatic thermal burn, including device extraction.</p>","PeriodicalId":21279,"journal":{"name":"Romanian journal of anaesthesia and intensive care","volume":"26 1","pages":"79-82"},"PeriodicalIF":0.0000,"publicationDate":"2019-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6502270/pdf/rjaic-26-1-79.pdf","citationCount":"0","resultStr":"{\"title\":\"Management of exposed pacemaker caused by burns.\",\"authors\":\"Christopher William Maxwell,&nbsp;Joshua Carson,&nbsp;Michael R Kaufmann,&nbsp;Brenda G Fahy\",\"doi\":\"10.2478/rjaic-2019-0012\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Annual implants of cardiovascular implantable devices (CIEDs) are increasing, thus increasing the risk of device exposure. This case presents CIED management issues following traumatic thermal injury. A 59-year-old female presented to intensive care with 42% total body surface area burn involving tissue over her pacemaker generator. Electrophysiologists interrogated and reprogrammed the pacer and observed the patient over 72 hours without pacing. Serratia bacteremia developed and cardiology recommended device removal. The pacemaker generator and leads were removed by cardiothoracic and burn surgery. Postoperatively, asystole required emergency transvenous pacing wire placement. During bacteremia treatment, cardiology planned to pace with an active-fixation screw-in lead with long-term plans to place a single right ventricular chamber leadless pacemaker because of the extensive burns. The patient developed fungemia and the family opted for comfort care. This case report discusses the management of a CIED exposed after a traumatic thermal burn, including device extraction.</p>\",\"PeriodicalId\":21279,\"journal\":{\"name\":\"Romanian journal of anaesthesia and intensive care\",\"volume\":\"26 1\",\"pages\":\"79-82\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6502270/pdf/rjaic-26-1-79.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Romanian journal of anaesthesia and intensive care\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2478/rjaic-2019-0012\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Romanian journal of anaesthesia and intensive care","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/rjaic-2019-0012","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

心血管植入式装置(cied)的年植入量正在增加,从而增加了装置暴露的风险。本病例提出外伤性热损伤后CIED的管理问题。一名59岁女性因体表总面积烧伤42%而被送进重症监护室,烧伤部位包括起搏器发电机上方的组织。电生理学家询问并重新编程起搏器,并在没有起搏的情况下观察患者72小时。出现了沙雷菌血症,心脏病学建议取出设备。心脏起搏器、发电机和导线通过胸外科和烧伤手术切除。术后,心脏骤停需要紧急经静脉起搏导线置入。在菌血症治疗期间,由于大面积烧伤,心脏病学计划使用主动固定螺钉起搏器起搏,长期计划放置单个右心室无铅起搏器。病人患上了真菌病,家人选择了舒适的护理。本病例报告讨论外伤性热烧伤后暴露的CIED的处理,包括取出装置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Management of exposed pacemaker caused by burns.

Management of exposed pacemaker caused by burns.

Annual implants of cardiovascular implantable devices (CIEDs) are increasing, thus increasing the risk of device exposure. This case presents CIED management issues following traumatic thermal injury. A 59-year-old female presented to intensive care with 42% total body surface area burn involving tissue over her pacemaker generator. Electrophysiologists interrogated and reprogrammed the pacer and observed the patient over 72 hours without pacing. Serratia bacteremia developed and cardiology recommended device removal. The pacemaker generator and leads were removed by cardiothoracic and burn surgery. Postoperatively, asystole required emergency transvenous pacing wire placement. During bacteremia treatment, cardiology planned to pace with an active-fixation screw-in lead with long-term plans to place a single right ventricular chamber leadless pacemaker because of the extensive burns. The patient developed fungemia and the family opted for comfort care. This case report discusses the management of a CIED exposed after a traumatic thermal burn, including device extraction.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.30
自引率
0.00%
发文量
0
期刊介绍: The Romanian Journal of Anaesthesia and Intensive Care is the official journal of the Romanian Society of Anaesthesia and Intensive Care and has been published continuously since 1994. It is intended mainly for anaesthesia and intensive care providers, but it is also aimed at specialists in emergency medical care and in pain research and management. The Journal is indexed in Scopus, Embase, PubMed Central as well as the databases of the Romanian Ministry of Education and Research (CNCSIS) B+ category. The Journal publishes two issues per year, the first one in April and the second one in October, and contains original articles, reviews, case reports, letters to the editor, book reviews and commentaries. The Journal is distributed free of charge to the members of the Romanian Society of Anaesthesia and Intensive Care.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信