{"title":"对比度增强和图像质量影响二维和三维超声心动图测定左心室容积:与磁共振成像的比较。","authors":"Jonas Jenner,&nbsp;Peder Sörensson,&nbsp;John Pernow,&nbsp;Kenneth Caidahl,&nbsp;Maria J Eriksson","doi":"10.1177/1179546819831980","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the effect of image quality and contrast enhancement (CE) on left ventricular (LV) volume determination by two- (2D) and three-dimensional (3D) echocardiography (2DE/3DE).</p><p><strong>Methods: </strong>We studied 32 post-myocardial infarction (MI) patients without (2DE/3DE) and with CE (CE2DE/CE3DE), in comparison with cardiac magnetic resonance imaging (CMR).</p><p><strong>Results: </strong>Two-dimensional echocardiography showed the largest negative bias versus CMR for diastolic and systolic volumes (-59, -28 mL, respectively) with lower biases for CE2DE (-37, -22 mL), 3DE (-31, -17 mL), and CE3DE (-17, -11 mL). Bias for ejection fraction (EF) ranged from -2.1% for 2DE to +1.4% for CE3DE. Agreement (intraclass correlation coefficient, ICC) for EF between CMR and 3DE (0.86 without and 0.85 with contrast) was better than for 2DE (0.73 without and 0.69 with contrast). The inter-/intra-observer coefficients of variation for EF varied from 16%/10% (2DE) to 6.9%/6.6% (CE2DE), and 8.3%/4.8% (3DE) to 6.7%/6.8% (CE3DE), respectively. The agreement (ICC) with CMR for EF measured by 2DE/3DE changed from 0.64/0.84 with poor image quality to 0.81/0.87 with moderate to good image quality.</p><p><strong>Conclusions: </strong>Three-dimensional echocardiography was more accurate than 2DE for estimating LV volumes, with less inter-/intra-observer variability in EF values. Contrast enhancement improved accuracy for both 2DE and 3DE and improved the inter-observer variability of EF estimates for 2DE and 3DE. Image quality had more impact on the agreement of EF values with CMR for 2DE than for 3DE. Our results emphasize the importance of using the same technique for longitudinal studies of LV EF and specially LV volumes.</p>","PeriodicalId":10419,"journal":{"name":"Clinical Medicine Insights. Cardiology","volume":"13 ","pages":"1179546819831980"},"PeriodicalIF":2.3000,"publicationDate":"2019-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/1179546819831980","citationCount":"6","resultStr":"{\"title\":\"Contrast Enhancement and Image Quality Influence Two- and Three-dimensional Echocardiographic Determination of Left Ventricular Volumes: Comparison With Magnetic Resonance Imaging.\",\"authors\":\"Jonas Jenner,&nbsp;Peder Sörensson,&nbsp;John Pernow,&nbsp;Kenneth Caidahl,&nbsp;Maria J Eriksson\",\"doi\":\"10.1177/1179546819831980\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the effect of image quality and contrast enhancement (CE) on left ventricular (LV) volume determination by two- (2D) and three-dimensional (3D) echocardiography (2DE/3DE).</p><p><strong>Methods: </strong>We studied 32 post-myocardial infarction (MI) patients without (2DE/3DE) and with CE (CE2DE/CE3DE), in comparison with cardiac magnetic resonance imaging (CMR).</p><p><strong>Results: </strong>Two-dimensional echocardiography showed the largest negative bias versus CMR for diastolic and systolic volumes (-59, -28 mL, respectively) with lower biases for CE2DE (-37, -22 mL), 3DE (-31, -17 mL), and CE3DE (-17, -11 mL). Bias for ejection fraction (EF) ranged from -2.1% for 2DE to +1.4% for CE3DE. Agreement (intraclass correlation coefficient, ICC) for EF between CMR and 3DE (0.86 without and 0.85 with contrast) was better than for 2DE (0.73 without and 0.69 with contrast). The inter-/intra-observer coefficients of variation for EF varied from 16%/10% (2DE) to 6.9%/6.6% (CE2DE), and 8.3%/4.8% (3DE) to 6.7%/6.8% (CE3DE), respectively. The agreement (ICC) with CMR for EF measured by 2DE/3DE changed from 0.64/0.84 with poor image quality to 0.81/0.87 with moderate to good image quality.</p><p><strong>Conclusions: </strong>Three-dimensional echocardiography was more accurate than 2DE for estimating LV volumes, with less inter-/intra-observer variability in EF values. Contrast enhancement improved accuracy for both 2DE and 3DE and improved the inter-observer variability of EF estimates for 2DE and 3DE. Image quality had more impact on the agreement of EF values with CMR for 2DE than for 3DE. Our results emphasize the importance of using the same technique for longitudinal studies of LV EF and specially LV volumes.</p>\",\"PeriodicalId\":10419,\"journal\":{\"name\":\"Clinical Medicine Insights. Cardiology\",\"volume\":\"13 \",\"pages\":\"1179546819831980\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2019-03-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1177/1179546819831980\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Medicine Insights. Cardiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/1179546819831980\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2019/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Medicine Insights. Cardiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/1179546819831980","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2019/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 6

摘要

目的:评价图像质量和对比度增强(CE)对二维(2D)和三维(3D)超声心动图(2DE/3DE)测定左心室(LV)容积的影响。方法:对32例无(2DE/3DE)和有CE (CE2DE/CE3DE)的心肌梗死后(MI)患者进行心脏磁共振成像(CMR)比较。结果:二维超声心动图显示,与CMR相比,舒张和收缩容积(分别为-59、-28 mL)的负偏最大,CE2DE(-37、-22 mL)、3DE(-31、-17 mL)和CE3DE(-17、-11 mL)的偏偏较小。射血分数(EF)的偏倚范围从2DE的-2.1%到CE3DE的+1.4%。CMR与3DE之间EF的一致性(类内相关系数,ICC)(无对比0.86,有对比0.85)优于2DE(无对比0.73,有对比0.69)。EF的观察者间/观察者内变异系数分别为16%/10% (2DE)至6.9%/6.6% (CE2DE)和8.3%/4.8% (3DE)至6.7%/6.8% (CE3DE)。2DE/3DE测量EF与CMR的一致性(ICC)从0.64/0.84(图像质量差)变为0.81/0.87(图像质量中佳)。结论:三维超声心动图在估计左室容积方面比二维超声心动图更准确,EF值的观察者间/内部变异性更小。对比度增强提高了2DE和3DE的准确性,并改善了2DE和3DE EF估计的观察者间可变性。图像质量对2DE的EF值与CMR的一致性的影响大于3DE。我们的结果强调了使用相同技术进行左室EF纵向研究的重要性,特别是左室容积。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Contrast Enhancement and Image Quality Influence Two- and Three-dimensional Echocardiographic Determination of Left Ventricular Volumes: Comparison With Magnetic Resonance Imaging.

Contrast Enhancement and Image Quality Influence Two- and Three-dimensional Echocardiographic Determination of Left Ventricular Volumes: Comparison With Magnetic Resonance Imaging.

Contrast Enhancement and Image Quality Influence Two- and Three-dimensional Echocardiographic Determination of Left Ventricular Volumes: Comparison With Magnetic Resonance Imaging.

Contrast Enhancement and Image Quality Influence Two- and Three-dimensional Echocardiographic Determination of Left Ventricular Volumes: Comparison With Magnetic Resonance Imaging.

Purpose: To evaluate the effect of image quality and contrast enhancement (CE) on left ventricular (LV) volume determination by two- (2D) and three-dimensional (3D) echocardiography (2DE/3DE).

Methods: We studied 32 post-myocardial infarction (MI) patients without (2DE/3DE) and with CE (CE2DE/CE3DE), in comparison with cardiac magnetic resonance imaging (CMR).

Results: Two-dimensional echocardiography showed the largest negative bias versus CMR for diastolic and systolic volumes (-59, -28 mL, respectively) with lower biases for CE2DE (-37, -22 mL), 3DE (-31, -17 mL), and CE3DE (-17, -11 mL). Bias for ejection fraction (EF) ranged from -2.1% for 2DE to +1.4% for CE3DE. Agreement (intraclass correlation coefficient, ICC) for EF between CMR and 3DE (0.86 without and 0.85 with contrast) was better than for 2DE (0.73 without and 0.69 with contrast). The inter-/intra-observer coefficients of variation for EF varied from 16%/10% (2DE) to 6.9%/6.6% (CE2DE), and 8.3%/4.8% (3DE) to 6.7%/6.8% (CE3DE), respectively. The agreement (ICC) with CMR for EF measured by 2DE/3DE changed from 0.64/0.84 with poor image quality to 0.81/0.87 with moderate to good image quality.

Conclusions: Three-dimensional echocardiography was more accurate than 2DE for estimating LV volumes, with less inter-/intra-observer variability in EF values. Contrast enhancement improved accuracy for both 2DE and 3DE and improved the inter-observer variability of EF estimates for 2DE and 3DE. Image quality had more impact on the agreement of EF values with CMR for 2DE than for 3DE. Our results emphasize the importance of using the same technique for longitudinal studies of LV EF and specially LV volumes.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Clinical Medicine Insights. Cardiology
Clinical Medicine Insights. Cardiology CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
5.20
自引率
3.30%
发文量
16
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信