{"title":"评价免疫放射法在死后测量眼内液中胰岛素浓度的有效性:初步结果。","authors":"Rafał Skowronek, Joanna Nowicka, Ewa Czech, Joanna Kulikowska","doi":"10.5114/amsik.2018.83093","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>In medicolegal practice, rare cases associated with suicidal, criminal or accidental overdose of insulin are both analytically and forensically challenging. The determination of insulin in post-mortem blood has limited diagnostic value, mainly on account of post-mortem chemical degradation processes (particularly hemolysis), and hence is not useful in medicolegal practice.</p><p><strong>Aim of the study: </strong>The aims of the study were: 1) to assess the usefulness of the immunoradiometric method, used in clinical practice, for post-mortem measurement of insulin concentration in the intraocular fluid, 2) to preliminarily evaluate the usefulness of the obtained results for toxicological and medicolegal assessment, and 3) to verify on the basis of our own material the validity of the cited literature data on the effect of hemolysis on the result of insulin level determination in post-mortem blood.</p><p><strong>Material and methods: </strong>The study material consisted of 93 samples of intraocular fluid collected during consecutive medicolegal autopsies performed in the Department of Forensic Medicine and Forensic Toxicology, Medical University of Silesia in Katowice. In addition, 10 samples of peripheral blood taken from living people (5 women and 5 men) for clinical and diagnostic purposes were analyzed. Insulin(e) IRMA KIT from IMMUNOTECH was used for the analyses.</p><p><strong>Results: </strong>In 86 (92.5%) samples, the insulin concentration was below the analytical sensitivity of the method (less than 0.5 μIU/ml), while in 7 cases it was in the range of 1.42-24.42 μIU/ml.</p><p><strong>Conclusions: </strong>Determination of the insulin level in the intraocular fluid by the immunoradiometric method provides an opportunity for objective verification of poisoning, however this claim requires further research.</p>","PeriodicalId":35709,"journal":{"name":"Archiwum Medycyny Sadowej i Kryminologii","volume":"68 3","pages":"161-170"},"PeriodicalIF":0.0000,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.5114/amsik.2018.83093","citationCount":"1","resultStr":"{\"title\":\"Evaluation of the usefulness of the immunoradiometric method for post-mortem measurement of insulin concentration in the intraocular fluid: preliminary results.\",\"authors\":\"Rafał Skowronek, Joanna Nowicka, Ewa Czech, Joanna Kulikowska\",\"doi\":\"10.5114/amsik.2018.83093\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>In medicolegal practice, rare cases associated with suicidal, criminal or accidental overdose of insulin are both analytically and forensically challenging. The determination of insulin in post-mortem blood has limited diagnostic value, mainly on account of post-mortem chemical degradation processes (particularly hemolysis), and hence is not useful in medicolegal practice.</p><p><strong>Aim of the study: </strong>The aims of the study were: 1) to assess the usefulness of the immunoradiometric method, used in clinical practice, for post-mortem measurement of insulin concentration in the intraocular fluid, 2) to preliminarily evaluate the usefulness of the obtained results for toxicological and medicolegal assessment, and 3) to verify on the basis of our own material the validity of the cited literature data on the effect of hemolysis on the result of insulin level determination in post-mortem blood.</p><p><strong>Material and methods: </strong>The study material consisted of 93 samples of intraocular fluid collected during consecutive medicolegal autopsies performed in the Department of Forensic Medicine and Forensic Toxicology, Medical University of Silesia in Katowice. In addition, 10 samples of peripheral blood taken from living people (5 women and 5 men) for clinical and diagnostic purposes were analyzed. Insulin(e) IRMA KIT from IMMUNOTECH was used for the analyses.</p><p><strong>Results: </strong>In 86 (92.5%) samples, the insulin concentration was below the analytical sensitivity of the method (less than 0.5 μIU/ml), while in 7 cases it was in the range of 1.42-24.42 μIU/ml.</p><p><strong>Conclusions: </strong>Determination of the insulin level in the intraocular fluid by the immunoradiometric method provides an opportunity for objective verification of poisoning, however this claim requires further research.</p>\",\"PeriodicalId\":35709,\"journal\":{\"name\":\"Archiwum Medycyny Sadowej i Kryminologii\",\"volume\":\"68 3\",\"pages\":\"161-170\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.5114/amsik.2018.83093\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Archiwum Medycyny Sadowej i Kryminologii\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5114/amsik.2018.83093\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archiwum Medycyny Sadowej i Kryminologii","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5114/amsik.2018.83093","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
Evaluation of the usefulness of the immunoradiometric method for post-mortem measurement of insulin concentration in the intraocular fluid: preliminary results.
Introduction: In medicolegal practice, rare cases associated with suicidal, criminal or accidental overdose of insulin are both analytically and forensically challenging. The determination of insulin in post-mortem blood has limited diagnostic value, mainly on account of post-mortem chemical degradation processes (particularly hemolysis), and hence is not useful in medicolegal practice.
Aim of the study: The aims of the study were: 1) to assess the usefulness of the immunoradiometric method, used in clinical practice, for post-mortem measurement of insulin concentration in the intraocular fluid, 2) to preliminarily evaluate the usefulness of the obtained results for toxicological and medicolegal assessment, and 3) to verify on the basis of our own material the validity of the cited literature data on the effect of hemolysis on the result of insulin level determination in post-mortem blood.
Material and methods: The study material consisted of 93 samples of intraocular fluid collected during consecutive medicolegal autopsies performed in the Department of Forensic Medicine and Forensic Toxicology, Medical University of Silesia in Katowice. In addition, 10 samples of peripheral blood taken from living people (5 women and 5 men) for clinical and diagnostic purposes were analyzed. Insulin(e) IRMA KIT from IMMUNOTECH was used for the analyses.
Results: In 86 (92.5%) samples, the insulin concentration was below the analytical sensitivity of the method (less than 0.5 μIU/ml), while in 7 cases it was in the range of 1.42-24.42 μIU/ml.
Conclusions: Determination of the insulin level in the intraocular fluid by the immunoradiometric method provides an opportunity for objective verification of poisoning, however this claim requires further research.
期刊介绍:
Archiwum Medycyny Sądowej i Kryminologii przyjmuje w języku polskim: prace doświadczalne, poglądowe, kazuistyczne, artykuły o charakterze szkoleniowym z medycyny sądowej, kryminologii i dziedzin pokrewnych, opracowania z zakresu etyki i deontologii lekarskiej, streszczenia prac obcych, oceny książek, sprawozdania z działalności PTMSiK, sprawozdania ze zjazdów krajowych i zagranicznych, komunikaty Zarządu Głównego PTMSiK, listy do Redakcji. Autor powinien podać, do jakiej kategorii zalicza tekst nadesłanej pracy. Przyjmowane do druku będą również prace autorów zagranicznych w języku angielskim.