{"title":"左主干中轴/远端支架的流变效应:计算流动力学分析。","authors":"Gianluca Rigatelli,&nbsp;Marco Zuin,&nbsp;Fabio Dell'Avvocata,&nbsp;Thach Nguyen","doi":"10.1177/1753944718765734","DOIUrl":null,"url":null,"abstract":"<p><p>Background The aim of this study was to evaluate the rheolytic effects of stenting a mid-shaft/distal left main coronary artery (LMCA) lesion with and without ostial coverage. Stenting of the LMCA has emerged as a valid alternative in place of traditional coronary bypass graft surgery. However, in case of mid-shaft/distal lesion, there is no consensus regarding the extension of the strut coverage up to the ostium or to stent only the culprit lesion. Methods We reconstructed a left main-left descending coronary artery (LM-LCA)-left circumflex (LCX) bifurcation after analysing 100 consecutive patients (mean age 71.4 ± 9.3, 49 males) with LM mid-shaft/distal disease. The mean diameter of proximal LM, left anterior descending (LAD) and LCX, evaluated with quantitative coronary angiography (QCA) was 4.62 ± 0.86 mm, 3.31 ± 0.92 mm, and 2.74 ± 0.93 mm, respectively. For the stent simulation, a third-generation, everolimus-eluting stent was virtually reconstructed. Results After virtual stenting, the net area averaged wall shear stress (WSS) of the model and the WSS at the LCA-LCX bifurcation resulted higher when the stent covered the culprit mid-shaft lesion only compared with the extension of the stent covering the ostium (3.68 versus 2.06 Pa, p = 0.01 and 3.97 versus 1.98 Pa, p < 0.001, respectively. Similarly, the static pressure and the Reynolds number were significantly higher after stent implantation covering up the ostium. At the ostium, the flow resulted more laminar when stenting only the mid-shaft lesion than including the ostium. Conclusions Although these findings cannot be translated directly into real practice our brief study suggests that stenting lesion 1:1 or extending the stent to cover the LM ostium impacts differently the rheolytic properties of LMCA bifurcation with potential insights for restenosis or thrombosis.</p>","PeriodicalId":23035,"journal":{"name":"Therapeutic Advances in Cardiovascular Disease","volume":"12 6","pages":"161-168"},"PeriodicalIF":2.6000,"publicationDate":"2018-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/1753944718765734","citationCount":"4","resultStr":"{\"title\":\"Rheolytic effects of left main mid-shaft/distal stenting: a computational flow dynamic analysis.\",\"authors\":\"Gianluca Rigatelli,&nbsp;Marco Zuin,&nbsp;Fabio Dell'Avvocata,&nbsp;Thach Nguyen\",\"doi\":\"10.1177/1753944718765734\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Background The aim of this study was to evaluate the rheolytic effects of stenting a mid-shaft/distal left main coronary artery (LMCA) lesion with and without ostial coverage. Stenting of the LMCA has emerged as a valid alternative in place of traditional coronary bypass graft surgery. However, in case of mid-shaft/distal lesion, there is no consensus regarding the extension of the strut coverage up to the ostium or to stent only the culprit lesion. Methods We reconstructed a left main-left descending coronary artery (LM-LCA)-left circumflex (LCX) bifurcation after analysing 100 consecutive patients (mean age 71.4 ± 9.3, 49 males) with LM mid-shaft/distal disease. The mean diameter of proximal LM, left anterior descending (LAD) and LCX, evaluated with quantitative coronary angiography (QCA) was 4.62 ± 0.86 mm, 3.31 ± 0.92 mm, and 2.74 ± 0.93 mm, respectively. For the stent simulation, a third-generation, everolimus-eluting stent was virtually reconstructed. Results After virtual stenting, the net area averaged wall shear stress (WSS) of the model and the WSS at the LCA-LCX bifurcation resulted higher when the stent covered the culprit mid-shaft lesion only compared with the extension of the stent covering the ostium (3.68 versus 2.06 Pa, p = 0.01 and 3.97 versus 1.98 Pa, p < 0.001, respectively. Similarly, the static pressure and the Reynolds number were significantly higher after stent implantation covering up the ostium. At the ostium, the flow resulted more laminar when stenting only the mid-shaft lesion than including the ostium. Conclusions Although these findings cannot be translated directly into real practice our brief study suggests that stenting lesion 1:1 or extending the stent to cover the LM ostium impacts differently the rheolytic properties of LMCA bifurcation with potential insights for restenosis or thrombosis.</p>\",\"PeriodicalId\":23035,\"journal\":{\"name\":\"Therapeutic Advances in Cardiovascular Disease\",\"volume\":\"12 6\",\"pages\":\"161-168\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2018-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1177/1753944718765734\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Therapeutic Advances in Cardiovascular Disease\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/1753944718765734\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2018/3/28 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Therapeutic Advances in Cardiovascular Disease","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/1753944718765734","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2018/3/28 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 4

摘要

本研究的目的是评估在有或没有口覆盖的情况下,在中轴/左主干冠状动脉(LMCA)病变处植入支架的流变作用。LMCA支架置入术已成为替代传统冠状动脉搭桥手术的有效方法。然而,在中轴/远端病变的情况下,对于支架覆盖范围延伸至开口或仅支架覆盖罪魁祸首病变尚无共识。方法对100例LM中轴/远端病变患者(平均年龄71.4±9.3岁,男性49例)进行分析,重建左主-左降支-左旋支分叉。定量冠状动脉造影(QCA)评估的左前降支(LAD)和左前降支(LCX)近端平均直径分别为4.62±0.86 mm、3.31±0.92 mm和2.74±0.93 mm。对于支架模拟,虚拟重建了第三代依维莫司洗脱支架。结果虚拟支架置入后,仅覆盖罪魁祸首中轴病变的模型净面积平均壁剪切应力(WSS)和LCA-LCX分叉处的WSS均高于覆盖开口的支架延伸(3.68比2.06 Pa, p = 0.01)和3.97比1.98 Pa, p < 0.001)。同样,支架置入术覆盖住气道后,静压和雷诺数明显升高。在开口处,当支架置入中轴病变时,血流更加层流。虽然这些发现不能直接转化为实际应用,但我们的简短研究表明,1:1的支架置入或将支架延伸到LM口对LMCA分叉的流变特性有不同的影响,可能对再狭窄或血栓形成有潜在的见解。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Rheolytic effects of left main mid-shaft/distal stenting: a computational flow dynamic analysis.

Rheolytic effects of left main mid-shaft/distal stenting: a computational flow dynamic analysis.

Rheolytic effects of left main mid-shaft/distal stenting: a computational flow dynamic analysis.

Rheolytic effects of left main mid-shaft/distal stenting: a computational flow dynamic analysis.

Background The aim of this study was to evaluate the rheolytic effects of stenting a mid-shaft/distal left main coronary artery (LMCA) lesion with and without ostial coverage. Stenting of the LMCA has emerged as a valid alternative in place of traditional coronary bypass graft surgery. However, in case of mid-shaft/distal lesion, there is no consensus regarding the extension of the strut coverage up to the ostium or to stent only the culprit lesion. Methods We reconstructed a left main-left descending coronary artery (LM-LCA)-left circumflex (LCX) bifurcation after analysing 100 consecutive patients (mean age 71.4 ± 9.3, 49 males) with LM mid-shaft/distal disease. The mean diameter of proximal LM, left anterior descending (LAD) and LCX, evaluated with quantitative coronary angiography (QCA) was 4.62 ± 0.86 mm, 3.31 ± 0.92 mm, and 2.74 ± 0.93 mm, respectively. For the stent simulation, a third-generation, everolimus-eluting stent was virtually reconstructed. Results After virtual stenting, the net area averaged wall shear stress (WSS) of the model and the WSS at the LCA-LCX bifurcation resulted higher when the stent covered the culprit mid-shaft lesion only compared with the extension of the stent covering the ostium (3.68 versus 2.06 Pa, p = 0.01 and 3.97 versus 1.98 Pa, p < 0.001, respectively. Similarly, the static pressure and the Reynolds number were significantly higher after stent implantation covering up the ostium. At the ostium, the flow resulted more laminar when stenting only the mid-shaft lesion than including the ostium. Conclusions Although these findings cannot be translated directly into real practice our brief study suggests that stenting lesion 1:1 or extending the stent to cover the LM ostium impacts differently the rheolytic properties of LMCA bifurcation with potential insights for restenosis or thrombosis.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Therapeutic Advances in Cardiovascular Disease
Therapeutic Advances in Cardiovascular Disease CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
3.50
自引率
0.00%
发文量
11
审稿时长
9 weeks
期刊介绍: The journal is aimed at clinicians and researchers from the cardiovascular disease field and will be a forum for all views and reviews relating to this discipline.Topics covered will include: ·arteriosclerosis ·cardiomyopathies ·coronary artery disease ·diabetes ·heart failure ·hypertension ·metabolic syndrome ·obesity ·peripheral arterial disease ·stroke ·arrhythmias ·genetics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信