{"title":"三维x射线显微镜分析假体负载种植体与平台切换和锥形连接:1例报告。","authors":"M DI Girolamo,&nbsp;L Baggi,&nbsp;P Pirelli,&nbsp;L Pappalardo,&nbsp;G Massei,&nbsp;F Iaculli,&nbsp;G Iezzi,&nbsp;A Piattelli,&nbsp;R Calcaterra","doi":"10.11138/orl/2017.10.3.241","DOIUrl":null,"url":null,"abstract":"<p><p>The histological and histomorphometrical examination were the gold standard in the qualitative and quantitative analyses of the peri-implant tissue around the implant. In recent years, the field of microscopy has witnessed a considerable enhancement of the performance of microscopes that have very high resolution performance and allowing very sophisticated analysis even larger than traditional preparations. The possibility to have an affordable analyses of whole implant with the surrounding different tissues (soft and hard tissues) without the traditional pre-treatment necessary for the histological analysis may represent a goal to describe material properties and behaviors or simply to visualize structural details. The aim of the present study were to evaluate a 3D X-ray microscopic analysis of peri-implant tissue compared to a traditional histological and histomorphometrical analysis of the peri-implant tissues around an implant with a conical connection associated with platform-switching in order to assess the validity of the new analysis technique.</p>","PeriodicalId":38303,"journal":{"name":"ORAL and Implantology","volume":"10 3","pages":"241-246"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5735390/pdf/241-246.pdf","citationCount":"0","resultStr":"{\"title\":\"3D X-ray microscopic analysys on a prosthetically loaded implant with platform-switching and conical connection: a case report.\",\"authors\":\"M DI Girolamo,&nbsp;L Baggi,&nbsp;P Pirelli,&nbsp;L Pappalardo,&nbsp;G Massei,&nbsp;F Iaculli,&nbsp;G Iezzi,&nbsp;A Piattelli,&nbsp;R Calcaterra\",\"doi\":\"10.11138/orl/2017.10.3.241\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The histological and histomorphometrical examination were the gold standard in the qualitative and quantitative analyses of the peri-implant tissue around the implant. In recent years, the field of microscopy has witnessed a considerable enhancement of the performance of microscopes that have very high resolution performance and allowing very sophisticated analysis even larger than traditional preparations. The possibility to have an affordable analyses of whole implant with the surrounding different tissues (soft and hard tissues) without the traditional pre-treatment necessary for the histological analysis may represent a goal to describe material properties and behaviors or simply to visualize structural details. The aim of the present study were to evaluate a 3D X-ray microscopic analysis of peri-implant tissue compared to a traditional histological and histomorphometrical analysis of the peri-implant tissues around an implant with a conical connection associated with platform-switching in order to assess the validity of the new analysis technique.</p>\",\"PeriodicalId\":38303,\"journal\":{\"name\":\"ORAL and Implantology\",\"volume\":\"10 3\",\"pages\":\"241-246\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-11-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5735390/pdf/241-246.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ORAL and Implantology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.11138/orl/2017.10.3.241\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2017/7/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ORAL and Implantology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11138/orl/2017.10.3.241","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2017/7/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

组织学和组织形态学检查是对种植体周围组织进行定性和定量分析的金标准。近年来,显微镜领域见证了显微镜性能的显著提高,显微镜具有非常高的分辨率,可以进行非常复杂的分析,甚至比传统的制备更大。对整个种植体和周围不同组织(软组织和硬组织)进行经济分析的可能性,而无需传统的组织学分析所需的预处理,可能代表了描述材料特性和行为或简单地可视化结构细节的目标。本研究的目的是评估种植体周围组织的3D x射线显微分析,与传统的种植体周围组织的组织学和组织形态计量学分析相比,种植体周围组织的锥形连接与平台切换相关,以评估新分析技术的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

3D X-ray microscopic analysys on a prosthetically loaded implant with platform-switching and conical connection: a case report.

3D X-ray microscopic analysys on a prosthetically loaded implant with platform-switching and conical connection: a case report.

3D X-ray microscopic analysys on a prosthetically loaded implant with platform-switching and conical connection: a case report.

The histological and histomorphometrical examination were the gold standard in the qualitative and quantitative analyses of the peri-implant tissue around the implant. In recent years, the field of microscopy has witnessed a considerable enhancement of the performance of microscopes that have very high resolution performance and allowing very sophisticated analysis even larger than traditional preparations. The possibility to have an affordable analyses of whole implant with the surrounding different tissues (soft and hard tissues) without the traditional pre-treatment necessary for the histological analysis may represent a goal to describe material properties and behaviors or simply to visualize structural details. The aim of the present study were to evaluate a 3D X-ray microscopic analysis of peri-implant tissue compared to a traditional histological and histomorphometrical analysis of the peri-implant tissues around an implant with a conical connection associated with platform-switching in order to assess the validity of the new analysis technique.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ORAL and Implantology
ORAL and Implantology Dentistry-Dentistry (all)
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信