外源激发下白蛋白溶液的超高频辐射。

Yu D Ivanov, K A Malsagova, V Yu Tatur, S G Vesnin, N D Ivanova, V S Ziborov
{"title":"外源激发下白蛋白溶液的超高频辐射。","authors":"Yu D Ivanov,&nbsp;K A Malsagova,&nbsp;V Yu Tatur,&nbsp;S G Vesnin,&nbsp;N D Ivanova,&nbsp;V S Ziborov","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The purpose of the research consisted in the measurement of nonequilibrium radiation in superhigh frequency (SHF) range from aqueous solution of albumin upon its mechanical stimulation.</p><p><strong>Methods: </strong>the monitoring of change in the ratio between brightness temperatures TSHF and TIR values after the mechanical stimulation of aqueous solution of albumin in the measuring cell at 35-39°С. The measurements of brightness temperatures were carried out with use of radiothermometer. SHF frequency range corresponded to 3.4-4.2 GHz, SHF frequency range corresponded to 8-13 mm.</p><p><strong>Results: </strong>It was found that mechanical stimulation of aqueous solution of albumin at the temperature ~39°С, the change in the ratio between TSHF and TIR occurs. This corresponds to emergence of nonequilibrium SHF radiation from the solution near the phase transition with ~39°С temperature.</p><p><strong>Conclusion: </strong>The effect of emergence of nonequilibrium SHF radiation from protein solution near its temperature 39°С was found. This temperature corresponds to the temperature of human organism upon a number of pathological states connected with inflammatory processes. The discovered effect can be used in the development of novel non-invasive methods of disease diagnostics.</p>","PeriodicalId":19857,"journal":{"name":"Patologicheskaia fiziologiia i eksperimental'naia terapiia","volume":"60 3","pages":"101-4"},"PeriodicalIF":0.0000,"publicationDate":"2016-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"SHF radiation from albumin solution upon external excitation.\",\"authors\":\"Yu D Ivanov,&nbsp;K A Malsagova,&nbsp;V Yu Tatur,&nbsp;S G Vesnin,&nbsp;N D Ivanova,&nbsp;V S Ziborov\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The purpose of the research consisted in the measurement of nonequilibrium radiation in superhigh frequency (SHF) range from aqueous solution of albumin upon its mechanical stimulation.</p><p><strong>Methods: </strong>the monitoring of change in the ratio between brightness temperatures TSHF and TIR values after the mechanical stimulation of aqueous solution of albumin in the measuring cell at 35-39°С. The measurements of brightness temperatures were carried out with use of radiothermometer. SHF frequency range corresponded to 3.4-4.2 GHz, SHF frequency range corresponded to 8-13 mm.</p><p><strong>Results: </strong>It was found that mechanical stimulation of aqueous solution of albumin at the temperature ~39°С, the change in the ratio between TSHF and TIR occurs. This corresponds to emergence of nonequilibrium SHF radiation from the solution near the phase transition with ~39°С temperature.</p><p><strong>Conclusion: </strong>The effect of emergence of nonequilibrium SHF radiation from protein solution near its temperature 39°С was found. This temperature corresponds to the temperature of human organism upon a number of pathological states connected with inflammatory processes. The discovered effect can be used in the development of novel non-invasive methods of disease diagnostics.</p>\",\"PeriodicalId\":19857,\"journal\":{\"name\":\"Patologicheskaia fiziologiia i eksperimental'naia terapiia\",\"volume\":\"60 3\",\"pages\":\"101-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Patologicheskaia fiziologiia i eksperimental'naia terapiia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Patologicheskaia fiziologiia i eksperimental'naia terapiia","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

研究了白蛋白水溶液在机械刺激下的超高频非平衡辐射的测量。方法:在测量池中对白蛋白水溶液在35-39°С下进行机械刺激后,监测亮度温度TSHF值与TIR值之比的变化。亮度温度的测量是用辐射温度计进行的。SHF频率范围对应3.4-4.2 GHz, SHF频率范围对应8-13 mm。结果:发现在~39°С温度下对白蛋白水溶液进行机械刺激,TSHF与TIR比值发生变化。这对应于温度为~39°С的相变附近的溶液中出现非平衡SHF辐射。结论:发现了蛋白质溶液在温度39°С附近产生非平衡SHF辐射的影响。这个温度对应于与炎症过程有关的许多病理状态下人体机体的温度。发现的效果可用于开发新的非侵入性疾病诊断方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
SHF radiation from albumin solution upon external excitation.

The purpose of the research consisted in the measurement of nonequilibrium radiation in superhigh frequency (SHF) range from aqueous solution of albumin upon its mechanical stimulation.

Methods: the monitoring of change in the ratio between brightness temperatures TSHF and TIR values after the mechanical stimulation of aqueous solution of albumin in the measuring cell at 35-39°С. The measurements of brightness temperatures were carried out with use of radiothermometer. SHF frequency range corresponded to 3.4-4.2 GHz, SHF frequency range corresponded to 8-13 mm.

Results: It was found that mechanical stimulation of aqueous solution of albumin at the temperature ~39°С, the change in the ratio between TSHF and TIR occurs. This corresponds to emergence of nonequilibrium SHF radiation from the solution near the phase transition with ~39°С temperature.

Conclusion: The effect of emergence of nonequilibrium SHF radiation from protein solution near its temperature 39°С was found. This temperature corresponds to the temperature of human organism upon a number of pathological states connected with inflammatory processes. The discovered effect can be used in the development of novel non-invasive methods of disease diagnostics.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信