应用韧带高级强化系统重建前交叉韧带术后膝关节稳定性。

Q3 Medicine
Sebastian Krupa, Aleksandra Królikowska, Paweł Reichert
{"title":"应用韧带高级强化系统重建前交叉韧带术后膝关节稳定性。","authors":"Sebastian Krupa,&nbsp;Aleksandra Królikowska,&nbsp;Paweł Reichert","doi":"10.17219/pim/68646","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>One of the goals of the synthetic materials used in knee joint reconstruction of the anterior cruciate ligament (ACL) is to improve the strength and stability of the graft immediately after the reconstruction. One of the synthetic grafts is a non-absorbable synthetic ligament device made of terephthalic polyethylene polyester fibers, the Ligament Advanced Reinforcement System (LARS).</p><p><strong>Objectives: </strong>The aim of the study was to assess postoperative knee joint stability in patients who had undergone ACL reconstruction using the LARS graft.</p><p><strong>Material and methods: </strong>The study group was comprised of 20 males who had undergone primary unilateral intraarticular ACL reconstruction using LARS. The patients were evaluated one day before the reconstruction and an average of six weeks postoperatively. Knee stability was evaluated manually using the Lachman test, anterior drawer test and pivot-shift test. Knee active range of motion (ROM) was measured.</p><p><strong>Results: </strong>Preoperatively, the Lachman test indicated abnormal/2+ results in the vast majority of the patients. The postoperative results in most of the patients were normal/0. The anterior drawer test results were also abnormal/2+ preoperatively and normal/0 postoperatively. The pivot-shift test was positive in all of the patients before the ACL reconstruction and negative after the surgery. In general, no differences were found in the ROM between the involved and uninvolved limbs and in the between-measurement comparison.</p><p><strong>Conclusions: </strong>The evaluation demonstrated significant progress from the preoperative to postoperative results in reducing anterior translation and anterolateral rotational instability of the tibia in patients who had undergone ACL reconstruction using the synthetic LARS graft. In the short-term follow-up assessments, restoration of anterior and anterolateral rotational stability of the operated knee joints was observed.</p>","PeriodicalId":20355,"journal":{"name":"Polimery w medycynie","volume":"46 2","pages":"155-161"},"PeriodicalIF":0.0000,"publicationDate":"2016-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"Postoperative Knee Joint Stability Following Anterior Cruciate Ligament Reconstruction Using the Ligament Advanced Reinforcement System.\",\"authors\":\"Sebastian Krupa,&nbsp;Aleksandra Królikowska,&nbsp;Paweł Reichert\",\"doi\":\"10.17219/pim/68646\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>One of the goals of the synthetic materials used in knee joint reconstruction of the anterior cruciate ligament (ACL) is to improve the strength and stability of the graft immediately after the reconstruction. One of the synthetic grafts is a non-absorbable synthetic ligament device made of terephthalic polyethylene polyester fibers, the Ligament Advanced Reinforcement System (LARS).</p><p><strong>Objectives: </strong>The aim of the study was to assess postoperative knee joint stability in patients who had undergone ACL reconstruction using the LARS graft.</p><p><strong>Material and methods: </strong>The study group was comprised of 20 males who had undergone primary unilateral intraarticular ACL reconstruction using LARS. The patients were evaluated one day before the reconstruction and an average of six weeks postoperatively. Knee stability was evaluated manually using the Lachman test, anterior drawer test and pivot-shift test. Knee active range of motion (ROM) was measured.</p><p><strong>Results: </strong>Preoperatively, the Lachman test indicated abnormal/2+ results in the vast majority of the patients. The postoperative results in most of the patients were normal/0. The anterior drawer test results were also abnormal/2+ preoperatively and normal/0 postoperatively. The pivot-shift test was positive in all of the patients before the ACL reconstruction and negative after the surgery. In general, no differences were found in the ROM between the involved and uninvolved limbs and in the between-measurement comparison.</p><p><strong>Conclusions: </strong>The evaluation demonstrated significant progress from the preoperative to postoperative results in reducing anterior translation and anterolateral rotational instability of the tibia in patients who had undergone ACL reconstruction using the synthetic LARS graft. In the short-term follow-up assessments, restoration of anterior and anterolateral rotational stability of the operated knee joints was observed.</p>\",\"PeriodicalId\":20355,\"journal\":{\"name\":\"Polimery w medycynie\",\"volume\":\"46 2\",\"pages\":\"155-161\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Polimery w medycynie\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17219/pim/68646\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Polimery w medycynie","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17219/pim/68646","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 10

摘要

背景:人工合成材料用于膝关节前交叉韧带(ACL)重建的目的之一是在重建后立即提高移植物的强度和稳定性。其中一种合成移植物是一种不可吸收的合成韧带装置,由对苯二甲酸聚乙烯聚酯纤维制成,韧带高级增强系统(LARS)。目的:本研究的目的是评估使用LARS移植物重建前交叉韧带患者的术后膝关节稳定性。材料和方法:研究组由20名男性组成,他们使用LARS进行了原发性单侧关节内ACL重建。患者在重建前一天和术后平均6周进行评估。人工评估膝关节稳定性,采用Lachman试验、前抽屉试验和枢轴移位试验。测量膝关节活动范围(ROM)。结果:术前Lachman试验显示绝大多数患者/2+结果异常。大多数患者术后结果为正常/0。前抽屉试验结果术前异常/2+,术后正常/0。所有患者在ACL重建前的pivot-shift试验均为阳性,手术后为阴性。总的来说,受累肢体和未受累肢体之间的ROM以及测量间比较没有差异。结论:从术前到术后的评估结果显示,使用合成LARS移植物重建ACL的患者在减少胫骨前移位和前外侧旋转不稳定方面取得了显著进展。在短期随访评估中,观察手术膝关节前外侧旋转稳定性的恢复情况。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Postoperative Knee Joint Stability Following Anterior Cruciate Ligament Reconstruction Using the Ligament Advanced Reinforcement System.

Background: One of the goals of the synthetic materials used in knee joint reconstruction of the anterior cruciate ligament (ACL) is to improve the strength and stability of the graft immediately after the reconstruction. One of the synthetic grafts is a non-absorbable synthetic ligament device made of terephthalic polyethylene polyester fibers, the Ligament Advanced Reinforcement System (LARS).

Objectives: The aim of the study was to assess postoperative knee joint stability in patients who had undergone ACL reconstruction using the LARS graft.

Material and methods: The study group was comprised of 20 males who had undergone primary unilateral intraarticular ACL reconstruction using LARS. The patients were evaluated one day before the reconstruction and an average of six weeks postoperatively. Knee stability was evaluated manually using the Lachman test, anterior drawer test and pivot-shift test. Knee active range of motion (ROM) was measured.

Results: Preoperatively, the Lachman test indicated abnormal/2+ results in the vast majority of the patients. The postoperative results in most of the patients were normal/0. The anterior drawer test results were also abnormal/2+ preoperatively and normal/0 postoperatively. The pivot-shift test was positive in all of the patients before the ACL reconstruction and negative after the surgery. In general, no differences were found in the ROM between the involved and uninvolved limbs and in the between-measurement comparison.

Conclusions: The evaluation demonstrated significant progress from the preoperative to postoperative results in reducing anterior translation and anterolateral rotational instability of the tibia in patients who had undergone ACL reconstruction using the synthetic LARS graft. In the short-term follow-up assessments, restoration of anterior and anterolateral rotational stability of the operated knee joints was observed.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Polimery w medycynie
Polimery w medycynie Medicine-Medicine (all)
CiteScore
3.30
自引率
0.00%
发文量
9
审稿时长
53 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信