{"title":"准确的点护理检测胎儿膜破裂:单克隆/多克隆免疫分析改进诊断性能特征。","authors":"Linda C Rogers, Laurie Scott, Jon E Block","doi":"10.4137/CMRH.S38386","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Accurate and timely diagnosis of rupture of membranes (ROM) is imperative to allow for gestational age-specific interventions. This study compared the diagnostic performance characteristics between two methods used for the detection of ROM as measured in the same patient.</p><p><strong>Methods: </strong>Vaginal secretions were evaluated using the conventional fern test as well as a point-of-care monoclonal/polyclonal immunoassay test (ROM Plus(®)) in 75 pregnant patients who presented to labor and delivery with complaints of leaking amniotic fluid. Both tests were compared to analytical confirmation of ROM using three external laboratory tests. Diagnostic performance characteristics were calculated including sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy.</p><p><strong>Results: </strong>Diagnostic performance characteristics uniformly favored ROM detection using the immunoassay test compared to the fern test: sensitivity (100% vs. 77.8%), specificity (94.8% vs. 79.3%), PPV (75% vs. 36.8%), NPV (100% vs. 95.8%), and accuracy (95.5% vs. 79.1%).</p><p><strong>Conclusions: </strong>The point-of-care immunoassay test provides improved diagnostic accuracy for the detection of ROM compared to fern testing. It has the potential of improving patient management decisions, thereby minimizing serious complications and perinatal morbidity.</p>","PeriodicalId":44130,"journal":{"name":"Clinical Medicine Insights-Reproductive Health","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2016-05-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.4137/CMRH.S38386","citationCount":"12","resultStr":"{\"title\":\"Accurate Point-of-Care Detection of Ruptured Fetal Membranes: Improved Diagnostic Performance Characteristics with a Monoclonal/Polyclonal Immunoassay.\",\"authors\":\"Linda C Rogers, Laurie Scott, Jon E Block\",\"doi\":\"10.4137/CMRH.S38386\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>Accurate and timely diagnosis of rupture of membranes (ROM) is imperative to allow for gestational age-specific interventions. This study compared the diagnostic performance characteristics between two methods used for the detection of ROM as measured in the same patient.</p><p><strong>Methods: </strong>Vaginal secretions were evaluated using the conventional fern test as well as a point-of-care monoclonal/polyclonal immunoassay test (ROM Plus(®)) in 75 pregnant patients who presented to labor and delivery with complaints of leaking amniotic fluid. Both tests were compared to analytical confirmation of ROM using three external laboratory tests. Diagnostic performance characteristics were calculated including sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy.</p><p><strong>Results: </strong>Diagnostic performance characteristics uniformly favored ROM detection using the immunoassay test compared to the fern test: sensitivity (100% vs. 77.8%), specificity (94.8% vs. 79.3%), PPV (75% vs. 36.8%), NPV (100% vs. 95.8%), and accuracy (95.5% vs. 79.1%).</p><p><strong>Conclusions: </strong>The point-of-care immunoassay test provides improved diagnostic accuracy for the detection of ROM compared to fern testing. It has the potential of improving patient management decisions, thereby minimizing serious complications and perinatal morbidity.</p>\",\"PeriodicalId\":44130,\"journal\":{\"name\":\"Clinical Medicine Insights-Reproductive Health\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-05-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.4137/CMRH.S38386\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Medicine Insights-Reproductive Health\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4137/CMRH.S38386\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2016/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Medicine Insights-Reproductive Health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4137/CMRH.S38386","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2016/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
Accurate Point-of-Care Detection of Ruptured Fetal Membranes: Improved Diagnostic Performance Characteristics with a Monoclonal/Polyclonal Immunoassay.
Objective: Accurate and timely diagnosis of rupture of membranes (ROM) is imperative to allow for gestational age-specific interventions. This study compared the diagnostic performance characteristics between two methods used for the detection of ROM as measured in the same patient.
Methods: Vaginal secretions were evaluated using the conventional fern test as well as a point-of-care monoclonal/polyclonal immunoassay test (ROM Plus(®)) in 75 pregnant patients who presented to labor and delivery with complaints of leaking amniotic fluid. Both tests were compared to analytical confirmation of ROM using three external laboratory tests. Diagnostic performance characteristics were calculated including sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy.
Results: Diagnostic performance characteristics uniformly favored ROM detection using the immunoassay test compared to the fern test: sensitivity (100% vs. 77.8%), specificity (94.8% vs. 79.3%), PPV (75% vs. 36.8%), NPV (100% vs. 95.8%), and accuracy (95.5% vs. 79.1%).
Conclusions: The point-of-care immunoassay test provides improved diagnostic accuracy for the detection of ROM compared to fern testing. It has the potential of improving patient management decisions, thereby minimizing serious complications and perinatal morbidity.
期刊介绍:
Clinical Medicine Insights: Reproductive Health is a peer reviewed; open access journal, which covers all aspects of Reproduction: Gynecology, Obstetrics, and Infertility, spanning both male and female issues, from the physical to the psychological and the social, including: sex, contraception, pregnancy, childbirth, and related topics such as social and emotional impacts. It welcomes original research and review articles from across the health sciences. Clinical subjects include fertility and sterility, infertility and assisted reproduction, IVF, fertility preservation despite gonadotoxic chemo- and/or radiotherapy, pregnancy problems, PPD, infections and disease, surgery, diagnosis, menopause, HRT, pelvic floor problems, reproductive cancers and environmental impacts on reproduction, although this list is by no means exhaustive Subjects covered include, but are not limited to: • fertility and sterility, • infertility and ART, • ART/IVF, • fertility preservation despite gonadotoxic chemo- and/or radiotherapy, • pregnancy problems, • Postpartum depression • Infections and disease, • Gyn/Ob surgery, • diagnosis, • Contraception • Premenstrual tension • Gynecologic Oncology • reproductive cancers • environmental impacts on reproduction, • Obstetrics/Gynaecology • Women''s Health • menopause, • HRT, • pelvic floor problems, • Paediatric and adolescent gynaecology • PID