端粒长度测量通过一种新的基于luminex的分析:盲法比较南方印迹。

International journal of molecular epidemiology and genetics Pub Date : 2016-03-23 eCollection Date: 2016-01-01
Brandon L Pierce, Farzana Jasmine, Shantanu Roy, Chenan Zhang, Abraham Aviv, Steven C Hunt, Habibul Ahsan, Muhammad G Kibriya
{"title":"端粒长度测量通过一种新的基于luminex的分析:盲法比较南方印迹。","authors":"Brandon L Pierce,&nbsp;Farzana Jasmine,&nbsp;Shantanu Roy,&nbsp;Chenan Zhang,&nbsp;Abraham Aviv,&nbsp;Steven C Hunt,&nbsp;Habibul Ahsan,&nbsp;Muhammad G Kibriya","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Telomere length (TL) is a potential biomarker of aging and age-related disease risk. We recently published a novel Luminex-based method for high-throughput, low-cost TL measurement. Here we describe a blinded comparison of the Luminex method to Southern blot, the most precise TL measurement method. Luminex and Southern blot measurements for the same 50 DNA samples were taken in two independent laboratories; each sample was measured twice, several months apart. The inter-assay CV for Luminex ranged from 5.5 to 9.1 (depending on CV estimation method), and Southern blot CV from 1.0 to 1.7. Both measures were inversely associated with age. The correlation between the repeated measurements was 0.66 for Luminex and 0.97 for Southern blot. The correlation between Southern blot and Luminex was 0.65 in round 1 and 0.75 in round 2, and the relationship showed no evidence of non-linearity. Our results demonstrate that the Luminex assay is a valid and reproducible method for high-throughput TL measurement. The Luminex assay involves no DNA amplification, which may make Luminex an attractive alternative to PCR-based TL measurement. </p>","PeriodicalId":73460,"journal":{"name":"International journal of molecular epidemiology and genetics","volume":"7 1","pages":"18-23"},"PeriodicalIF":0.0000,"publicationDate":"2016-03-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4858612/pdf/ijmeg0007-0018.pdf","citationCount":"0","resultStr":"{\"title\":\"Telomere length measurement by a novel Luminex-based assay: a blinded comparison to Southern blot.\",\"authors\":\"Brandon L Pierce,&nbsp;Farzana Jasmine,&nbsp;Shantanu Roy,&nbsp;Chenan Zhang,&nbsp;Abraham Aviv,&nbsp;Steven C Hunt,&nbsp;Habibul Ahsan,&nbsp;Muhammad G Kibriya\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Telomere length (TL) is a potential biomarker of aging and age-related disease risk. We recently published a novel Luminex-based method for high-throughput, low-cost TL measurement. Here we describe a blinded comparison of the Luminex method to Southern blot, the most precise TL measurement method. Luminex and Southern blot measurements for the same 50 DNA samples were taken in two independent laboratories; each sample was measured twice, several months apart. The inter-assay CV for Luminex ranged from 5.5 to 9.1 (depending on CV estimation method), and Southern blot CV from 1.0 to 1.7. Both measures were inversely associated with age. The correlation between the repeated measurements was 0.66 for Luminex and 0.97 for Southern blot. The correlation between Southern blot and Luminex was 0.65 in round 1 and 0.75 in round 2, and the relationship showed no evidence of non-linearity. Our results demonstrate that the Luminex assay is a valid and reproducible method for high-throughput TL measurement. The Luminex assay involves no DNA amplification, which may make Luminex an attractive alternative to PCR-based TL measurement. </p>\",\"PeriodicalId\":73460,\"journal\":{\"name\":\"International journal of molecular epidemiology and genetics\",\"volume\":\"7 1\",\"pages\":\"18-23\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-03-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4858612/pdf/ijmeg0007-0018.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International journal of molecular epidemiology and genetics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2016/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of molecular epidemiology and genetics","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2016/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

端粒长度(TL)是衰老和年龄相关疾病风险的潜在生物标志物。我们最近发表了一种新的基于luminex的高通量、低成本TL测量方法。在这里,我们描述了Luminex方法与最精确的TL测量方法Southern blot的盲法比较。在两个独立的实验室对相同的50个DNA样本进行了Luminex和Southern blot测量;每个样本测量两次,间隔几个月。Luminex的检测间CV范围为5.5至9.1(取决于CV估计方法),而Southern blot的CV范围为1.0至1.7。这两项指标都与年龄呈负相关。Luminex重复测量的相关性为0.66,Southern blot的相关性为0.97。在第1轮和第2轮中,Southern blot与Luminex的相关系数分别为0.65和0.75,两者之间没有非线性关系。我们的结果表明,Luminex法是一种有效的、可重复的高通量TL测量方法。Luminex检测不涉及DNA扩增,这可能使Luminex成为基于pcr的TL测量的有吸引力的替代方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Telomere length measurement by a novel Luminex-based assay: a blinded comparison to Southern blot.

Telomere length measurement by a novel Luminex-based assay: a blinded comparison to Southern blot.

Telomere length measurement by a novel Luminex-based assay: a blinded comparison to Southern blot.

Telomere length measurement by a novel Luminex-based assay: a blinded comparison to Southern blot.

Telomere length (TL) is a potential biomarker of aging and age-related disease risk. We recently published a novel Luminex-based method for high-throughput, low-cost TL measurement. Here we describe a blinded comparison of the Luminex method to Southern blot, the most precise TL measurement method. Luminex and Southern blot measurements for the same 50 DNA samples were taken in two independent laboratories; each sample was measured twice, several months apart. The inter-assay CV for Luminex ranged from 5.5 to 9.1 (depending on CV estimation method), and Southern blot CV from 1.0 to 1.7. Both measures were inversely associated with age. The correlation between the repeated measurements was 0.66 for Luminex and 0.97 for Southern blot. The correlation between Southern blot and Luminex was 0.65 in round 1 and 0.75 in round 2, and the relationship showed no evidence of non-linearity. Our results demonstrate that the Luminex assay is a valid and reproducible method for high-throughput TL measurement. The Luminex assay involves no DNA amplification, which may make Luminex an attractive alternative to PCR-based TL measurement.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信