{"title":"腹腔镜胆囊切除术患者使用Supreme和ProSeal喉罩气道的比较:一项随机对照试验","authors":"Lakesh K. Anand , Nitika Goel , Manpreet Singh , Dheeraj Kapoor","doi":"10.1016/j.aat.2016.03.001","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><p>The single-use LMA Supreme (Teleflex, Inc., Wayne, PA, USA) and the LMA ProSeal (Teleflex, Inc., Wayne, PA, USA) laryngeal mask airway (LMA) have similar characteristics. To date, studies have not achieved a consensus regarding the oropharyngeal leak pressure (OLP) of the LMA Supreme and LMA ProSeal, and there is little information on their efficacy in laparoscopic cholecystectomy. This study compared the safety and efficacy of the LMA Supreme and LMA ProSeal devices in patients undergoing laparoscopic cholecystectomy.</p></div><div><h3>Method</h3><p>Eighty-four eligible consenting patients were randomly allocated to the LMA Supreme group or the LMA ProSeal group. Both groups received the standard anesthesia technique. The Supreme or ProSeal LMA was inserted, the cuff was inflated to 60 cmH<sub>2</sub>O, and the LMA position was confirmed. Anesthesia was maintained using propofol and 50% oxygen in air. A gastric tube was inserted through the drain tube of the LMA to deflate the stomach, and the first attempt success rate and insertion time were recorded. During surgery, the intra-abdominal pressure was maintained at 12 mmHg. The fiberoptic view of the larynx was determined by passing a flexible fiberoptic bronchoscope. The OLPs, success rate, insertion time, hemodynamic and respiratory parameters, and complications were recorded at different time points.</p></div><div><h3>Results</h3><p>The mean OLP was significantly lower in the LMA Supreme group than in the LMA ProSeal group (24.9 ± 5.3 cmH<sub>2</sub>O vs. 28.4 ± 5.8 cmH<sub>2</sub>O; <em>p</em> < 0.01). The first attempt success rate and ease of insertion grading for LMA were higher in the Supreme group. The insertion time was lower in the Supreme group than in the ProSeal group (<em>p</em> < 0.01). The fiberoptic view was better with the ProSeal LMA. The hemodynamic and ventilatory parameters and postoperative sore throat were comparable in both groups.</p></div><div><h3>Conclusion</h3><p>The LMA ProSeal has a higher OLP than the LMA Supreme. The success rate of first attempt insertion and ease of insertion were better for the LMA Supreme group and the insertion time was lower in the LMA Supreme group. The Supreme and ProSeal LMAs were both effective for positive pressure ventilation in laparoscopic cholecystectomy.</p></div>","PeriodicalId":87042,"journal":{"name":"Acta anaesthesiologica Taiwanica : official journal of the Taiwan Society of Anesthesiologists","volume":"54 2","pages":"Pages 44-50"},"PeriodicalIF":0.0000,"publicationDate":"2016-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.aat.2016.03.001","citationCount":"17","resultStr":"{\"title\":\"Comparison of the Supreme and the ProSeal laryngeal mask airway in patients undergoing laparoscopic cholecystectomy: A randomized controlled trial\",\"authors\":\"Lakesh K. Anand , Nitika Goel , Manpreet Singh , Dheeraj Kapoor\",\"doi\":\"10.1016/j.aat.2016.03.001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objective</h3><p>The single-use LMA Supreme (Teleflex, Inc., Wayne, PA, USA) and the LMA ProSeal (Teleflex, Inc., Wayne, PA, USA) laryngeal mask airway (LMA) have similar characteristics. To date, studies have not achieved a consensus regarding the oropharyngeal leak pressure (OLP) of the LMA Supreme and LMA ProSeal, and there is little information on their efficacy in laparoscopic cholecystectomy. This study compared the safety and efficacy of the LMA Supreme and LMA ProSeal devices in patients undergoing laparoscopic cholecystectomy.</p></div><div><h3>Method</h3><p>Eighty-four eligible consenting patients were randomly allocated to the LMA Supreme group or the LMA ProSeal group. Both groups received the standard anesthesia technique. The Supreme or ProSeal LMA was inserted, the cuff was inflated to 60 cmH<sub>2</sub>O, and the LMA position was confirmed. Anesthesia was maintained using propofol and 50% oxygen in air. A gastric tube was inserted through the drain tube of the LMA to deflate the stomach, and the first attempt success rate and insertion time were recorded. During surgery, the intra-abdominal pressure was maintained at 12 mmHg. The fiberoptic view of the larynx was determined by passing a flexible fiberoptic bronchoscope. The OLPs, success rate, insertion time, hemodynamic and respiratory parameters, and complications were recorded at different time points.</p></div><div><h3>Results</h3><p>The mean OLP was significantly lower in the LMA Supreme group than in the LMA ProSeal group (24.9 ± 5.3 cmH<sub>2</sub>O vs. 28.4 ± 5.8 cmH<sub>2</sub>O; <em>p</em> < 0.01). The first attempt success rate and ease of insertion grading for LMA were higher in the Supreme group. The insertion time was lower in the Supreme group than in the ProSeal group (<em>p</em> < 0.01). The fiberoptic view was better with the ProSeal LMA. The hemodynamic and ventilatory parameters and postoperative sore throat were comparable in both groups.</p></div><div><h3>Conclusion</h3><p>The LMA ProSeal has a higher OLP than the LMA Supreme. The success rate of first attempt insertion and ease of insertion were better for the LMA Supreme group and the insertion time was lower in the LMA Supreme group. The Supreme and ProSeal LMAs were both effective for positive pressure ventilation in laparoscopic cholecystectomy.</p></div>\",\"PeriodicalId\":87042,\"journal\":{\"name\":\"Acta anaesthesiologica Taiwanica : official journal of the Taiwan Society of Anesthesiologists\",\"volume\":\"54 2\",\"pages\":\"Pages 44-50\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.aat.2016.03.001\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta anaesthesiologica Taiwanica : official journal of the Taiwan Society of Anesthesiologists\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1875459716300157\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta anaesthesiologica Taiwanica : official journal of the Taiwan Society of Anesthesiologists","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1875459716300157","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Comparison of the Supreme and the ProSeal laryngeal mask airway in patients undergoing laparoscopic cholecystectomy: A randomized controlled trial
Objective
The single-use LMA Supreme (Teleflex, Inc., Wayne, PA, USA) and the LMA ProSeal (Teleflex, Inc., Wayne, PA, USA) laryngeal mask airway (LMA) have similar characteristics. To date, studies have not achieved a consensus regarding the oropharyngeal leak pressure (OLP) of the LMA Supreme and LMA ProSeal, and there is little information on their efficacy in laparoscopic cholecystectomy. This study compared the safety and efficacy of the LMA Supreme and LMA ProSeal devices in patients undergoing laparoscopic cholecystectomy.
Method
Eighty-four eligible consenting patients were randomly allocated to the LMA Supreme group or the LMA ProSeal group. Both groups received the standard anesthesia technique. The Supreme or ProSeal LMA was inserted, the cuff was inflated to 60 cmH2O, and the LMA position was confirmed. Anesthesia was maintained using propofol and 50% oxygen in air. A gastric tube was inserted through the drain tube of the LMA to deflate the stomach, and the first attempt success rate and insertion time were recorded. During surgery, the intra-abdominal pressure was maintained at 12 mmHg. The fiberoptic view of the larynx was determined by passing a flexible fiberoptic bronchoscope. The OLPs, success rate, insertion time, hemodynamic and respiratory parameters, and complications were recorded at different time points.
Results
The mean OLP was significantly lower in the LMA Supreme group than in the LMA ProSeal group (24.9 ± 5.3 cmH2O vs. 28.4 ± 5.8 cmH2O; p < 0.01). The first attempt success rate and ease of insertion grading for LMA were higher in the Supreme group. The insertion time was lower in the Supreme group than in the ProSeal group (p < 0.01). The fiberoptic view was better with the ProSeal LMA. The hemodynamic and ventilatory parameters and postoperative sore throat were comparable in both groups.
Conclusion
The LMA ProSeal has a higher OLP than the LMA Supreme. The success rate of first attempt insertion and ease of insertion were better for the LMA Supreme group and the insertion time was lower in the LMA Supreme group. The Supreme and ProSeal LMAs were both effective for positive pressure ventilation in laparoscopic cholecystectomy.