{"title":"基于供体特异性抗体动态监测的活体肾移植早期干预。","authors":"Yu Chen, Lang-Yan Li, Xiao-Yan Lou, Hao Wang, Lei Zhang, You-Hua Zhu","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>This study aims to analyze the clinical application of HLA donor specific antibodies (DSA) detected by Luminex single antigen beads and to discuss the impact of early intervention on renal function in DSA positive kidney transplant patients. In 64 cases of living-related renal transplantation, DSA was detected using Luminex single antigen bead assays before and after transplantation. The positive recipients were given intravenous immunoglobulin (IVIG) and increased doses of mycophenolate mofetil (MMF). The relationship between DSA and renal function was analyzed. In all transplant recipients, DSA was negative prior to transplantation. Ten DSA positive recipients were found after HLA mismatched transplantations. With intervention, two DSA positive recipients became DSA negative. In six cases, the patients' DSA intensity decreased more than 50%. In the remaining two cases, DSA intensity did not significantly decline, and within 3-6 months, antibody-mediated rejection (AMR) appeared and renal function was impaired. From our research, we conclude that dynamic monitoring of DSA using Luminex single antigen beads may help predict future changes in renal function. In addition, early application of IVIG and increasing doses of MMF can reduce the incidence of AMR.</p>","PeriodicalId":77074,"journal":{"name":"Clinical transplants","volume":" ","pages":"205-8"},"PeriodicalIF":0.0000,"publicationDate":"2014-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Early Intervention in Living Kidney Transplantation Based on Dynamic Monitoring of Donor Specific Antibodies.\",\"authors\":\"Yu Chen, Lang-Yan Li, Xiao-Yan Lou, Hao Wang, Lei Zhang, You-Hua Zhu\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study aims to analyze the clinical application of HLA donor specific antibodies (DSA) detected by Luminex single antigen beads and to discuss the impact of early intervention on renal function in DSA positive kidney transplant patients. In 64 cases of living-related renal transplantation, DSA was detected using Luminex single antigen bead assays before and after transplantation. The positive recipients were given intravenous immunoglobulin (IVIG) and increased doses of mycophenolate mofetil (MMF). The relationship between DSA and renal function was analyzed. In all transplant recipients, DSA was negative prior to transplantation. Ten DSA positive recipients were found after HLA mismatched transplantations. With intervention, two DSA positive recipients became DSA negative. In six cases, the patients' DSA intensity decreased more than 50%. In the remaining two cases, DSA intensity did not significantly decline, and within 3-6 months, antibody-mediated rejection (AMR) appeared and renal function was impaired. From our research, we conclude that dynamic monitoring of DSA using Luminex single antigen beads may help predict future changes in renal function. In addition, early application of IVIG and increasing doses of MMF can reduce the incidence of AMR.</p>\",\"PeriodicalId\":77074,\"journal\":{\"name\":\"Clinical transplants\",\"volume\":\" \",\"pages\":\"205-8\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical transplants\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical transplants","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
本研究旨在分析Luminex单抗原珠检测HLA供体特异性抗体(HLA donor specific antibodies, DSA)的临床应用,探讨早期干预对DSA阳性肾移植患者肾功能的影响。对64例活体肾移植患者,采用Luminex单抗原珠检测移植前后的DSA。阳性受体给予静脉注射免疫球蛋白(IVIG)和增加剂量的霉酚酸酯(MMF)。分析DSA与肾功能的关系。在所有移植受者中,移植前DSA均为阴性。HLA错配移植后DSA阳性受者10例。干预后,两名DSA阳性受者变为DSA阴性。6例患者DSA强度下降超过50%。其余2例患者DSA强度无明显下降,3-6个月内出现抗体介导的排斥反应(AMR),肾功能受损。从我们的研究中,我们得出结论,使用Luminex单抗原珠动态监测DSA可能有助于预测未来肾功能的变化。此外,早期应用IVIG和增加MMF剂量可以减少AMR的发生率。
Early Intervention in Living Kidney Transplantation Based on Dynamic Monitoring of Donor Specific Antibodies.
This study aims to analyze the clinical application of HLA donor specific antibodies (DSA) detected by Luminex single antigen beads and to discuss the impact of early intervention on renal function in DSA positive kidney transplant patients. In 64 cases of living-related renal transplantation, DSA was detected using Luminex single antigen bead assays before and after transplantation. The positive recipients were given intravenous immunoglobulin (IVIG) and increased doses of mycophenolate mofetil (MMF). The relationship between DSA and renal function was analyzed. In all transplant recipients, DSA was negative prior to transplantation. Ten DSA positive recipients were found after HLA mismatched transplantations. With intervention, two DSA positive recipients became DSA negative. In six cases, the patients' DSA intensity decreased more than 50%. In the remaining two cases, DSA intensity did not significantly decline, and within 3-6 months, antibody-mediated rejection (AMR) appeared and renal function was impaired. From our research, we conclude that dynamic monitoring of DSA using Luminex single antigen beads may help predict future changes in renal function. In addition, early application of IVIG and increasing doses of MMF can reduce the incidence of AMR.