利用玻璃微泡快速分选全血中的CD4+ T细胞。

Chia-Hsien Hsu, Chihchen Chen, Daniel Irimia, Mehmet Toner
{"title":"利用玻璃微泡快速分选全血中的CD4+ T细胞。","authors":"Chia-Hsien Hsu,&nbsp;Chihchen Chen,&nbsp;Daniel Irimia,&nbsp;Mehmet Toner","doi":"10.1142/S2339547815500016","DOIUrl":null,"url":null,"abstract":"<p><p>The isolation of CD4 positive T lymphocyte (CD4+) from peripheral blood is important for monitoring patients after HIV infection. Here, we demonstrate a fast isolation strategy for CD4+ cells that involves mixing blood and glass microbubbles. After the specific binding of target cells to the microbubbles carrying specific antibodies on their surface, target cells will spontaneously float to the top of the blood vial and can be quickly separated. Using this strategy, we demonstrate that the isolation of CD4+ cells in less than 5 minutes and with better than 90% efficiency. This strategy for cell isolation based on buoyancy and glass microbubbles is quick and inexpensive, minimizes blood handling, does not require magnetic fields, or centrifugation equipment, and could lead to new, efficient strategies for AIDS diagnosis in resource-limited areas.</p>","PeriodicalId":22332,"journal":{"name":"TECHNOLOGY","volume":"3 1","pages":"38-44"},"PeriodicalIF":0.0000,"publicationDate":"2015-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1142/S2339547815500016","citationCount":"12","resultStr":"{\"title\":\"Fast sorting of CD4+ T cells from whole blood using glass microbubbles.\",\"authors\":\"Chia-Hsien Hsu,&nbsp;Chihchen Chen,&nbsp;Daniel Irimia,&nbsp;Mehmet Toner\",\"doi\":\"10.1142/S2339547815500016\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The isolation of CD4 positive T lymphocyte (CD4+) from peripheral blood is important for monitoring patients after HIV infection. Here, we demonstrate a fast isolation strategy for CD4+ cells that involves mixing blood and glass microbubbles. After the specific binding of target cells to the microbubbles carrying specific antibodies on their surface, target cells will spontaneously float to the top of the blood vial and can be quickly separated. Using this strategy, we demonstrate that the isolation of CD4+ cells in less than 5 minutes and with better than 90% efficiency. This strategy for cell isolation based on buoyancy and glass microbubbles is quick and inexpensive, minimizes blood handling, does not require magnetic fields, or centrifugation equipment, and could lead to new, efficient strategies for AIDS diagnosis in resource-limited areas.</p>\",\"PeriodicalId\":22332,\"journal\":{\"name\":\"TECHNOLOGY\",\"volume\":\"3 1\",\"pages\":\"38-44\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1142/S2339547815500016\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"TECHNOLOGY\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1142/S2339547815500016\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"TECHNOLOGY","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1142/S2339547815500016","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

摘要

从外周血中分离CD4阳性T淋巴细胞(CD4+)对HIV感染后患者的监测具有重要意义。在这里,我们展示了一种快速分离CD4+细胞的策略,包括混合血液和玻璃微泡。靶细胞与表面携带特异性抗体的微泡特异性结合后,靶细胞会自发地浮到血瓶的顶部,可以快速分离。使用这种策略,我们证明了CD4+细胞的分离在不到5分钟的时间内,效率优于90%。这种基于浮力和玻璃微泡的细胞分离策略快速而廉价,最大限度地减少了血液处理,不需要磁场或离心设备,并且可能为资源有限地区的艾滋病诊断提供新的有效策略。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Fast sorting of CD4+ T cells from whole blood using glass microbubbles.

Fast sorting of CD4+ T cells from whole blood using glass microbubbles.

Fast sorting of CD4+ T cells from whole blood using glass microbubbles.

Fast sorting of CD4+ T cells from whole blood using glass microbubbles.

The isolation of CD4 positive T lymphocyte (CD4+) from peripheral blood is important for monitoring patients after HIV infection. Here, we demonstrate a fast isolation strategy for CD4+ cells that involves mixing blood and glass microbubbles. After the specific binding of target cells to the microbubbles carrying specific antibodies on their surface, target cells will spontaneously float to the top of the blood vial and can be quickly separated. Using this strategy, we demonstrate that the isolation of CD4+ cells in less than 5 minutes and with better than 90% efficiency. This strategy for cell isolation based on buoyancy and glass microbubbles is quick and inexpensive, minimizes blood handling, does not require magnetic fields, or centrifugation equipment, and could lead to new, efficient strategies for AIDS diagnosis in resource-limited areas.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
TECHNOLOGY
TECHNOLOGY ENGINEERING, MULTIDISCIPLINARY-
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信