人工耳蜗植入:人工耳蜗高度的变化。

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY
Accounts of Chemical Research Pub Date : 2025-08-01 Epub Date: 2022-10-17 DOI:10.1177/01455613221134860
Afrah Alshalan, Yassin Abdelsamad, Majed Assiri, Abdulrahman Alsanosi
{"title":"人工耳蜗植入:人工耳蜗高度的变化。","authors":"Afrah Alshalan, Yassin Abdelsamad, Majed Assiri, Abdulrahman Alsanosi","doi":"10.1177/01455613221134860","DOIUrl":null,"url":null,"abstract":"<p><p>This study aimed to identify the association between different cochlear metrics, including the basal turn diameter (A-value), the basal turn width (B-value), and the height of the cochlea (H-value). We also reported an association between H-value and hearing outcomes with cochlear implants (CI). This is a retrospective study that included all patients who underwent CI procedures between 2012 and 2018 at a tertiary center and have; preoperative high-resolution computed tomography (CT)<b>,</b> normal cochlea, postoperative follow-up duration of at least 2 years, scores of the category auditory performance II (CAP-II), and speech intelligibility rating (SIR) scales. A total of 65 ears implanted with CI in 46 patients (24 boys and 20 girls; mean age of 7 (±10) years) fulfilled the inclusion criteria. We found significant positive correlations between A vs B, A vs H, and B vs H (<i>P</i>-value = 0.008, 0.018, and 0.0039, respectively). We also found a significant positive relationship between A, B, and H values and cochlear duct length (CDL) (<i>P</i>-value < 0.0001, 0.008, and 0.018, respectively). Finally, the H-value was significantly correlated with the SIR (<i>P</i>-value = 0.027). However, its correlation with the CAP score was not statistically significant (<i>P</i>-value = 0.62). Cochlear height significantly correlated with CDL and the other cochlear parameters. The variation in cochlear height can also affect speech outcomes in patients undergoing CI. Therefore, the H-value together with the other cochlear metrics should be adequately assessed preoperatively in CI patients.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":" ","pages":"501-507"},"PeriodicalIF":16.4000,"publicationDate":"2025-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Cochlear Implantation: The Variation in Cochlear Height.\",\"authors\":\"Afrah Alshalan, Yassin Abdelsamad, Majed Assiri, Abdulrahman Alsanosi\",\"doi\":\"10.1177/01455613221134860\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study aimed to identify the association between different cochlear metrics, including the basal turn diameter (A-value), the basal turn width (B-value), and the height of the cochlea (H-value). We also reported an association between H-value and hearing outcomes with cochlear implants (CI). This is a retrospective study that included all patients who underwent CI procedures between 2012 and 2018 at a tertiary center and have; preoperative high-resolution computed tomography (CT)<b>,</b> normal cochlea, postoperative follow-up duration of at least 2 years, scores of the category auditory performance II (CAP-II), and speech intelligibility rating (SIR) scales. A total of 65 ears implanted with CI in 46 patients (24 boys and 20 girls; mean age of 7 (±10) years) fulfilled the inclusion criteria. We found significant positive correlations between A vs B, A vs H, and B vs H (<i>P</i>-value = 0.008, 0.018, and 0.0039, respectively). We also found a significant positive relationship between A, B, and H values and cochlear duct length (CDL) (<i>P</i>-value < 0.0001, 0.008, and 0.018, respectively). Finally, the H-value was significantly correlated with the SIR (<i>P</i>-value = 0.027). However, its correlation with the CAP score was not statistically significant (<i>P</i>-value = 0.62). Cochlear height significantly correlated with CDL and the other cochlear parameters. The variation in cochlear height can also affect speech outcomes in patients undergoing CI. Therefore, the H-value together with the other cochlear metrics should be adequately assessed preoperatively in CI patients.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":\" \",\"pages\":\"501-507\"},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2025-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1177/01455613221134860\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/10/17 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1177/01455613221134860","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/10/17 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在确定不同耳蜗指标(包括基底面直径(A 值)、基底面宽度(B 值)和耳蜗高度(H 值))之间的关联。我们还报告了 H 值与人工耳蜗(CI)听力结果之间的关联。这是一项回顾性研究,纳入了 2012 年至 2018 年期间在一家三级中心接受人工耳蜗手术的所有患者,这些患者均具备以下条件:术前接受过高分辨率计算机断层扫描(CT)、耳蜗正常、术后随访时间至少 2 年、听觉表现类别 II(CAP-II)评分和言语清晰度评分(SIR)量表。共有 46 名患者(24 名男孩和 20 名女孩;平均年龄为 7(±10)岁)的 65 只耳朵植入了 CI,符合纳入标准。我们发现 A vs B、A vs H 和 B vs H 之间存在明显的正相关性(P 值分别为 0.008、0.018 和 0.0039)。我们还发现 A 值、B 值和 H 值与耳蜗导管长度(CDL)之间存在明显的正相关关系(P 值分别小于 0.0001、0.008 和 0.018)。最后,H 值与 SIR 显著相关(P 值 = 0.027)。然而,其与 CAP 评分的相关性在统计学上并不显著(P 值 = 0.62)。耳蜗高度与 CDL 及其他耳蜗参数有明显的相关性。耳蜗高度的变化也会影响 CI 患者的言语效果。因此,CI 患者术前应充分评估耳蜗高度值和其他耳蜗指标。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Cochlear Implantation: The Variation in Cochlear Height.

This study aimed to identify the association between different cochlear metrics, including the basal turn diameter (A-value), the basal turn width (B-value), and the height of the cochlea (H-value). We also reported an association between H-value and hearing outcomes with cochlear implants (CI). This is a retrospective study that included all patients who underwent CI procedures between 2012 and 2018 at a tertiary center and have; preoperative high-resolution computed tomography (CT), normal cochlea, postoperative follow-up duration of at least 2 years, scores of the category auditory performance II (CAP-II), and speech intelligibility rating (SIR) scales. A total of 65 ears implanted with CI in 46 patients (24 boys and 20 girls; mean age of 7 (±10) years) fulfilled the inclusion criteria. We found significant positive correlations between A vs B, A vs H, and B vs H (P-value = 0.008, 0.018, and 0.0039, respectively). We also found a significant positive relationship between A, B, and H values and cochlear duct length (CDL) (P-value < 0.0001, 0.008, and 0.018, respectively). Finally, the H-value was significantly correlated with the SIR (P-value = 0.027). However, its correlation with the CAP score was not statistically significant (P-value = 0.62). Cochlear height significantly correlated with CDL and the other cochlear parameters. The variation in cochlear height can also affect speech outcomes in patients undergoing CI. Therefore, the H-value together with the other cochlear metrics should be adequately assessed preoperatively in CI patients.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信