用n1 -羟基- n1, n2 -二苯基苯并脒修饰碳糊电极电化学测定环境样品中镉(II)

IF 2.3 3区 化学 Q3 CHEMISTRY, ANALYTICAL
Journal of Analytical Methods in Chemistry Pub Date : 2022-09-22 eCollection Date: 2022-01-01 DOI:10.1155/2022/3426575
Endale Tesfaye, Bhagwan Singh Chandravanshi, Negussie Negash, Merid Tessema
{"title":"用n1 -羟基- n1, n2 -二苯基苯并脒修饰碳糊电极电化学测定环境样品中镉(II)","authors":"Endale Tesfaye,&nbsp;Bhagwan Singh Chandravanshi,&nbsp;Negussie Negash,&nbsp;Merid Tessema","doi":"10.1155/2022/3426575","DOIUrl":null,"url":null,"abstract":"<p><p>The present study introduces a novel electrode for rapid, highly sensitive, and selective electrochemical sensor for cadmium(II) using 5% N<sup>1</sup>-hydroxy-N<sup>1</sup>,N<sup>2</sup>-diphenylbenzamidine (HDPBA) modified carbon paste electrode (CPE) (HDPBA‒CPE). Surface characterizations and structural analysis of the proposed HDPBA‒CPE were performed using several analytical techniques. The voltammetric measurements of Cd(II) were conducted by cyclic voltammetry (CV) and square wave anodic stripping voltammetry (SWASV). Several experimental conditions such as composition and pH of buffer solutions, HDPBA composition, accumulation potential and time, and other voltammetric conditions were optimized. Cd(II) was preconcentrated on the modified electrode surface for 270 s using Britton Robinson (B-R) buffer (0.1 M, pH 4) at -1.0 V versus Ag/AgCl, followed by electrochemical oxidation of the accumulated Cd(II) in the positive scan of SWASV after a quiet time of 10 s. Under optimized parameters, the proposed method showed a linear range of 0.3-100 nM Cd(II) with a detection limit of 0.032 nM. The fabricated HDPBA-modified carbon paste electrode exhibited excellent sensitivity, selectivity, stability, and reproducibility (with RSD of 3.8%). The developed HDPBA‒CPE was used for the quantification of Cd(II) in tobacco and environmental water samples, and it was found to be applicable for the determination of different types of real samples.</p>","PeriodicalId":14974,"journal":{"name":"Journal of Analytical Methods in Chemistry","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2022-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9553701/pdf/","citationCount":"2","resultStr":"{\"title\":\"A Novel Carbon Paste Electrode Modified with N<sup>1</sup>-Hydroxy-N<sup>1</sup>,N<sup>2</sup>-Diphenylbenzamidine for the Electrochemical Determination of Cadmium(II) in Environmental Samples.\",\"authors\":\"Endale Tesfaye,&nbsp;Bhagwan Singh Chandravanshi,&nbsp;Negussie Negash,&nbsp;Merid Tessema\",\"doi\":\"10.1155/2022/3426575\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The present study introduces a novel electrode for rapid, highly sensitive, and selective electrochemical sensor for cadmium(II) using 5% N<sup>1</sup>-hydroxy-N<sup>1</sup>,N<sup>2</sup>-diphenylbenzamidine (HDPBA) modified carbon paste electrode (CPE) (HDPBA‒CPE). Surface characterizations and structural analysis of the proposed HDPBA‒CPE were performed using several analytical techniques. The voltammetric measurements of Cd(II) were conducted by cyclic voltammetry (CV) and square wave anodic stripping voltammetry (SWASV). Several experimental conditions such as composition and pH of buffer solutions, HDPBA composition, accumulation potential and time, and other voltammetric conditions were optimized. Cd(II) was preconcentrated on the modified electrode surface for 270 s using Britton Robinson (B-R) buffer (0.1 M, pH 4) at -1.0 V versus Ag/AgCl, followed by electrochemical oxidation of the accumulated Cd(II) in the positive scan of SWASV after a quiet time of 10 s. Under optimized parameters, the proposed method showed a linear range of 0.3-100 nM Cd(II) with a detection limit of 0.032 nM. The fabricated HDPBA-modified carbon paste electrode exhibited excellent sensitivity, selectivity, stability, and reproducibility (with RSD of 3.8%). The developed HDPBA‒CPE was used for the quantification of Cd(II) in tobacco and environmental water samples, and it was found to be applicable for the determination of different types of real samples.</p>\",\"PeriodicalId\":14974,\"journal\":{\"name\":\"Journal of Analytical Methods in Chemistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2022-09-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9553701/pdf/\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Analytical Methods in Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1155/2022/3426575\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Methods in Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1155/2022/3426575","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 2

摘要

采用5% n1 -羟基- n1, n2 -二苯基苯并脒(HDPBA)修饰碳糊电极(CPE) (HDPBA - CPE)制备了一种快速、高灵敏度、高选择性的镉(II)电化学传感器。采用多种分析技术对所提出的hdppa - cpe进行了表面表征和结构分析。采用循环伏安法(CV)和方波阳极溶出伏安法(SWASV)对Cd(II)进行了伏安测定。对缓冲液的组成和pH、HDPBA的组成、积累电位和时间等实验条件进行了优化。使用布里顿罗宾逊(B-R)缓冲液(0.1 M, pH 4)在-1.0 V下对Ag/AgCl预浓缩270 s,静置10 s后,对SWASV阳性扫描中积累的Cd(II)进行电化学氧化。在优化参数下,该方法在0.3 ~ 100 nM范围内呈线性,检出限为0.032 nM。制备的hdpba修饰碳糊电极具有良好的灵敏度、选择性、稳定性和重复性(RSD为3.8%)。将所建立的HDPBA-CPE用于烟草和环境水样中Cd(II)的定量分析,发现该方法适用于不同类型实际样品的测定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

A Novel Carbon Paste Electrode Modified with N<sup>1</sup>-Hydroxy-N<sup>1</sup>,N<sup>2</sup>-Diphenylbenzamidine for the Electrochemical Determination of Cadmium(II) in Environmental Samples.

A Novel Carbon Paste Electrode Modified with N<sup>1</sup>-Hydroxy-N<sup>1</sup>,N<sup>2</sup>-Diphenylbenzamidine for the Electrochemical Determination of Cadmium(II) in Environmental Samples.

A Novel Carbon Paste Electrode Modified with N<sup>1</sup>-Hydroxy-N<sup>1</sup>,N<sup>2</sup>-Diphenylbenzamidine for the Electrochemical Determination of Cadmium(II) in Environmental Samples.

A Novel Carbon Paste Electrode Modified with N1-Hydroxy-N1,N2-Diphenylbenzamidine for the Electrochemical Determination of Cadmium(II) in Environmental Samples.

The present study introduces a novel electrode for rapid, highly sensitive, and selective electrochemical sensor for cadmium(II) using 5% N1-hydroxy-N1,N2-diphenylbenzamidine (HDPBA) modified carbon paste electrode (CPE) (HDPBA‒CPE). Surface characterizations and structural analysis of the proposed HDPBA‒CPE were performed using several analytical techniques. The voltammetric measurements of Cd(II) were conducted by cyclic voltammetry (CV) and square wave anodic stripping voltammetry (SWASV). Several experimental conditions such as composition and pH of buffer solutions, HDPBA composition, accumulation potential and time, and other voltammetric conditions were optimized. Cd(II) was preconcentrated on the modified electrode surface for 270 s using Britton Robinson (B-R) buffer (0.1 M, pH 4) at -1.0 V versus Ag/AgCl, followed by electrochemical oxidation of the accumulated Cd(II) in the positive scan of SWASV after a quiet time of 10 s. Under optimized parameters, the proposed method showed a linear range of 0.3-100 nM Cd(II) with a detection limit of 0.032 nM. The fabricated HDPBA-modified carbon paste electrode exhibited excellent sensitivity, selectivity, stability, and reproducibility (with RSD of 3.8%). The developed HDPBA‒CPE was used for the quantification of Cd(II) in tobacco and environmental water samples, and it was found to be applicable for the determination of different types of real samples.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Analytical Methods in Chemistry
Journal of Analytical Methods in Chemistry CHEMISTRY, ANALYTICAL-ENGINEERING, CIVIL
CiteScore
4.80
自引率
3.80%
发文量
79
审稿时长
6-12 weeks
期刊介绍: Journal of Analytical Methods in Chemistry publishes papers reporting methods and instrumentation for chemical analysis, and their application to real-world problems. Articles may be either practical or theoretical. Subject areas include (but are by no means limited to): Separation Spectroscopy Mass spectrometry Chromatography Analytical Sample Preparation Electrochemical analysis Hyphenated techniques Data processing As well as original research, Journal of Analytical Methods in Chemistry also publishes focused review articles that examine the state of the art, identify emerging trends, and suggest future directions for developing fields.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信