Megan Parmer, Yun Hwa Walter Wang, Eliza H Hersh, Linda Zhang, Edward Chin, Scott Q Nguyen
{"title":"腹腔镜袖式胃切除术后钉线渗漏的处理。","authors":"Megan Parmer, Yun Hwa Walter Wang, Eliza H Hersh, Linda Zhang, Edward Chin, Scott Q Nguyen","doi":"10.4293/JSLS.2022.00029","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objectives: </strong>Laparoscopic sleeve gastrectomy has become one of the most popular bariatric surgeries in the United States with a low rate of morbidity and effective weight loss. However, staple line leak remains a feared complication requiring a lengthy and difficult treatment course until resolution. This study outlines the various treatment methods used within a high-volume bariatric practice for successful leak resolution without necessitating a conversion procedure.</p><p><strong>Methods: </strong>A retrospective review was conducted on all patients with staple line leak after laparoscopic sleeve gastrectomy in a three-surgeon bariatric practice from January 1, 2010 to December 31, 2019.</p><p><strong>Results: </strong>A total of 10 staple line leaks were identified with a leak rate of 0.9%. Patients presented on average 29.3 days postoperatively and were all diagnosed on computed tomography. Three patients were initially managed operatively with washout and drainage procedure. Six patients were managed endoscopically initially with either stent or over-the-scope clip placement. Most patients required multiple interventions with an average of 2.4 interventions per patient. Average time to leak resolution was 48.2 days (15-95 days).</p><p><strong>Conclusion: </strong>Management of staple line leaks after laparoscopic sleeve gastrectomy requires a multimodal approach usually requiring multiple interventions before leak resolution. We demonstrate effective utilization of varying interventions that lead to effective leak resolution and avoid conversion operations.</p>","PeriodicalId":17679,"journal":{"name":"JSLS : Journal of the Society of Laparoendoscopic Surgeons","volume":"26 3","pages":""},"PeriodicalIF":1.4000,"publicationDate":"2022-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/b7/a5/e2022.00029.PMC9439287.pdf","citationCount":"0","resultStr":"{\"title\":\"Management of Staple Line Leaks after Laparoscopic Sleeve Gastrectomy.\",\"authors\":\"Megan Parmer, Yun Hwa Walter Wang, Eliza H Hersh, Linda Zhang, Edward Chin, Scott Q Nguyen\",\"doi\":\"10.4293/JSLS.2022.00029\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background and objectives: </strong>Laparoscopic sleeve gastrectomy has become one of the most popular bariatric surgeries in the United States with a low rate of morbidity and effective weight loss. However, staple line leak remains a feared complication requiring a lengthy and difficult treatment course until resolution. This study outlines the various treatment methods used within a high-volume bariatric practice for successful leak resolution without necessitating a conversion procedure.</p><p><strong>Methods: </strong>A retrospective review was conducted on all patients with staple line leak after laparoscopic sleeve gastrectomy in a three-surgeon bariatric practice from January 1, 2010 to December 31, 2019.</p><p><strong>Results: </strong>A total of 10 staple line leaks were identified with a leak rate of 0.9%. Patients presented on average 29.3 days postoperatively and were all diagnosed on computed tomography. Three patients were initially managed operatively with washout and drainage procedure. Six patients were managed endoscopically initially with either stent or over-the-scope clip placement. Most patients required multiple interventions with an average of 2.4 interventions per patient. Average time to leak resolution was 48.2 days (15-95 days).</p><p><strong>Conclusion: </strong>Management of staple line leaks after laparoscopic sleeve gastrectomy requires a multimodal approach usually requiring multiple interventions before leak resolution. We demonstrate effective utilization of varying interventions that lead to effective leak resolution and avoid conversion operations.</p>\",\"PeriodicalId\":17679,\"journal\":{\"name\":\"JSLS : Journal of the Society of Laparoendoscopic Surgeons\",\"volume\":\"26 3\",\"pages\":\"\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2022-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/b7/a5/e2022.00029.PMC9439287.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JSLS : Journal of the Society of Laparoendoscopic Surgeons\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4293/JSLS.2022.00029\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JSLS : Journal of the Society of Laparoendoscopic Surgeons","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4293/JSLS.2022.00029","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
Management of Staple Line Leaks after Laparoscopic Sleeve Gastrectomy.
Background and objectives: Laparoscopic sleeve gastrectomy has become one of the most popular bariatric surgeries in the United States with a low rate of morbidity and effective weight loss. However, staple line leak remains a feared complication requiring a lengthy and difficult treatment course until resolution. This study outlines the various treatment methods used within a high-volume bariatric practice for successful leak resolution without necessitating a conversion procedure.
Methods: A retrospective review was conducted on all patients with staple line leak after laparoscopic sleeve gastrectomy in a three-surgeon bariatric practice from January 1, 2010 to December 31, 2019.
Results: A total of 10 staple line leaks were identified with a leak rate of 0.9%. Patients presented on average 29.3 days postoperatively and were all diagnosed on computed tomography. Three patients were initially managed operatively with washout and drainage procedure. Six patients were managed endoscopically initially with either stent or over-the-scope clip placement. Most patients required multiple interventions with an average of 2.4 interventions per patient. Average time to leak resolution was 48.2 days (15-95 days).
Conclusion: Management of staple line leaks after laparoscopic sleeve gastrectomy requires a multimodal approach usually requiring multiple interventions before leak resolution. We demonstrate effective utilization of varying interventions that lead to effective leak resolution and avoid conversion operations.
期刊介绍:
JSLS, Journal of the Society of Laparoscopic & Robotic Surgeons publishes original scientific articles on basic science and technical topics in all the fields involved with laparoscopic, robotic, and minimally invasive surgery. CRSLS, MIS Case Reports from SLS is dedicated to the publication of Case Reports in the field of minimally invasive surgery. The journals seek to advance our understandings and practice of minimally invasive, image-guided surgery by providing a forum for all relevant disciplines and by promoting the exchange of information and ideas across specialties.